Installation 

Chimney 

The chimney height and the position of the chimney terminal should conform to Building Regulations. 
 
Check that the chimney is in good condition, dry, free from cracks and obstructions.  The diameter of 
the flue should not be less than 127mm and not more than 230mm. If any of these requirements are not 
met, the chimney should be lined by a suitable method. 
 
The chimney must be swept before connection to the stove. 
 
Where the chimney is believed to have previously served an open fire installation, it is possible that the 
higher flue gas temperature from the stove may loosen deposits that were previously firmly adhered, 
with the consequent risk of flue blockage.   It is therefore recommended that the chimney be swept a 
second time within a month of regular use after installation. 
 
If you have any doubts about the suitability of your chimney, consult your local dealer/stockist. 
 
If there is no existing chimney then either a prefabricated block chimney in accordance with Building 
Regulations Approved Document J, or a twin-walled insulated stainless steel flue to BS 4543 can be 
used.  These chimneys must be fitted in accordance with the manufacturer’s instructions and Building 
Regulations. 

Flue Draught 

A  flue  draught  of  minimum  1.2mm  to  a  maximum  2.5mm  water  gauge  is  required  for  satisfactory 
appliance performance.  The flue draught should be checked under fire at high output. If it exceeds the 
recommended  maximum,  a  draught  stabiliser  must  be  fitted  so  that  the  rate  of  burning  can  be 
controlled and to prevent over firing. If the reading is less than the recommended minimum then the 
performance of the appliance will be compromised. 

Connection to the Chimney 

An existing fireplace opening can be bricked up or sealed with a register plate.  A short length of flue 
pipe of a minimum  127mm internal  diameter  may then be used to  connect  the stove to  the chimney.  
This flue pipe should be of 316 grade stainless steel or vitreous enamelled, nominal thickness 1.2mm.  
Ensure that the pipe end is no closer than 76mm to the side or rear chimney walls. 
 
Ideally,  the  old  fireplace  should  be  filled  in  so  that  there  is  a  smooth  streamlined  entry  into  the  flue 
way. 
The length of any horizontal run of flue pipe must not exceed 127mm. 
It is essential that all connections between the stove and chimney-flue are sealed and made airtight. 
Both  the  chimney  and  flue  pipe  must  be  accessible  for  cleaning  and  if  ANY  parts  of  the  chimney 
cannot  be  reached  through  the  stove  (with  baffle  brick  removed),  a  soot  door  must  be  fitted  in  a 
suitable position to enable this to be done. 

Air Supply 

The room or space containing this appliance needs no additional ventilation, unless a draught stabiliser 
is  fitted,  in  which  case  a  permanent  air  opening  of  at  least  1470mm

should  be  provided.    Due 

consideration should be given to air requirements for any other appliances in the same room or space.  
Any air opening must be kept clear from blockage or obstruction. 

 

 
 

Содержание Norreskoven

Страница 1: ...ilding Control Officer can approve the completed installation should a non accredited engineer undertake the installation It is an offence under UK law not to comply with this advice Please hand these instructions to the stove user when the installation is complete Leave the system ready for operation and instruct the user in the correct use of the appliance and operation of controls v01 11b ...

Страница 2: ...S EN 13240 Total Efficiency 73 5 Nominal Heat Output 4 4 kW Mean CO Emission at 13 O2 0 17 Mean Flue Gas Temperature 311 C Flue Gas Mass Flow 4 6 g s This appliance is not suitable for use in a shared flue This appliance is suitable for intermittent burning ...

Страница 3: ...p smokecontrol defra gov uk locations php If the stove is being installed in a location which is not in a Smoke Control Area the screw shown in the diagram below may be removed Remove the two screws holding in the Top Air Deflector and then remove the Smoke Control screw Replace the Top Air Deflector If the stove is installed in a Smoke Control Area this screw must not be removed Doing so may leav...

Страница 4: ...he flue collar and blanking plate until finger tight Place the gasket in position on the top plate of the stove and lower the flue collar or blanking plate as required on to the stove top taking care to line up the studs with the fixing holes Secure in place using the M6 nuts and washers Fit the two M8 coach bolts in the flue collar to blank off the optional damper handle holes Blanking Plate Fit ...

Страница 5: ...wering it into the firebox and removing it a 3 Remove the grate bars by lifting them out in pairs b a b 4 Remove the side bricks by lifting them up and swinging the bottom end towards the centre of the stove c 5 Remove the rear brick d c d 1 Remove the cam bar by lifting the left hand end of it upwards until it clears the side casting pulling the left hand end towards the front of the stove until ...

Страница 6: ...the front plate by lifting it out On double door stoves it will be necessary to push the front plate towards the back of the stove to free it from the location pins h before lifting it out k h k 4 Remove the rear grate support m 5 Remove the base casting n m n Location pin ...

Страница 7: ...6 Building Engineering Services Competence Accreditation BESCA Limited www hvca org uk www besca org uk 0800 652 5533 HETAS Ltd Heating Equipment Testing and Approval Scheme www hetas co uk 01462 634721 NAPIT Registration Ltd www napit org uk 0870 444 1392 NICEIC Group Ltd www niceic org uk 0800 013 0900 Health and Safety Precautions Special care must be taken when installing the stove such that t...

Страница 8: ...er fire at high output If it exceeds the recommended maximum a draught stabiliser must be fitted so that the rate of burning can be controlled and to prevent over firing If the reading is less than the recommended minimum then the performance of the appliance will be compromised Connection to the Chimney An existing fireplace opening can be bricked up or sealed with a register plate A short length...

Страница 9: ...e stove can be recessed into a suitably sized fireplace but a free air gap of at least 150 mm must be left around the sides and top of the stove and at least 50mm at the back of the stove to obtain maximum heat output and for access to the rear of the stove The hearth should extend at least 300 mm from the front of the stove The stove should stand wholly above a solid non combustible hearth at lea...

Страница 10: ...ioning ensure that the operating instructions and operating tools for the stove are left with the customer Ensure to advise the customer on the correct use of the appliance with the fuels likely to be used on the stove and warn them to use only the recommended fuels for the stove Advise the user on what to do should smoke or fumes be emitted from the stove The user should be warned to use a firegu...

Страница 11: ...rimary secondary and tertiary air inlets must be kept clear from obstruction and blockage Air Controls Primary Air The Slider under the ash lip of the stove controls the Primary air This provides a conventional air draught to the bed of the fire The control is open when the Slider is pushed towards the right of the Stove Secondary Air Secondary air is controlled via the slider above the doors it i...

Страница 12: ...l will control the burn rate of the stove When refuelling the stove the primary air should be opened for 2 3 minutes to ensure clean ignition of the new fuel Loading the Stove Wood burns best on a bed of ash and it is therefore only necessary to remove surplus ash from on top of the grate occasionally Do not let the ash level under the grate reach above the primary air inlet holes If allowed to bu...

Страница 13: ...et the fire out or eject and safely dispose of fuel from the appliance 3 Check for flue chimney blockage and clean if required 4 Do not attempt to re light the fire until the cause has been identified and corrected If necessary seek professional advice Adverse weather In a small number of installations occasional local weather conditions e g wind from a particular direction may cause downdraught i...

Страница 14: ...rom heat Firebricks In normal use these can last for many years It is possible however to crack them if logs are continually jammed against them or if they are frequently struck with a poker Check periodically for seriously cracked bricks which can be replaced with new available from your dealer Rope Check the rope around the door and glass If rope is becoming detached use proprietary rope glue to...

Страница 15: ...product and no cause for concern Stove Body The stove is finished with a heat resistant paint and this can be cleaned with a soft brush Do not clean whilst the stove is hot wait until it has cooled down The finish can be renovated with proprietary stove paint Single Door Catch The door catch may require adjustment to maintain the door seal By slackening the locking nut and turning the door handle ...

Страница 16: ... Door Handle Black HCE05 053 Handle Spacer Black HCE05 054 Handle Nut Black HCE05 055 Shaft Door Handle HCE05 038 Circlip FLRX07 M8 Full Nut FSHM08 Door Catch HMS04 037 STOVE SPARES SINGLE DOOR DOUBLE DOORS R H Door HMS04 004 Door Glass HMS04 054 Glass Gasket HMS04 056 Glass Clip Screw HHR08 046 FSJM05008SS L H Door HMS04 006 ...

Страница 17: ...75 Side Bricks HCE06 020 Recouping Baffle HCE06 044 Riddling Bars Lower CNS06 001 6 Upper CNS06 002 5 Riddling Support HCE05 065 Cast Iron Inner Base HCE05 042M Ashpan HCE05 011 Cast Iron Side Plates L H HCE05 044 R H HCE05 045 Cam Bar HCE06 010 Cam Hole Plate HCE06 030 Slider Knob HCE06 059 Washer x3 FWFM06016 Support HCE06 046 Shaft HCE06 048 Spacer Primary Air Valve x3 HCE06 049 Primary Air Val...

Страница 18: ... Nut FNLM12Z Catch Shaft HCE05 082 Catch End HCE09 089 Catch Spacer HCE05 081S 4mm x 14mm Roll Pin FPGM04014 Catch Barrel HCE09 091 Catch Collar HCE09 092S M3 Ball Bearing FBBM03C Snap Ring FLRWM0160 M6 Socket Set Screw FSGM06006CP QUARTER TURN DOOR HANDLE DOUBLE DOOR MULTIFUEL PARTS ...

Отзывы: