FIGURE 25
Water valve hose connects to this connection
This inlet is
connected
to the intake
manifold
WAT
ER
PU
MP
HEA
TE
R C
OR
E
www.classicautoair.com •
866.435.7801
Classic Auto Air has done extensive testing on the correct
method to install the water valve in order to get a repeatable and
progressive temperature control.
Your water valve
MUST
be
installed per these instructions!... (if not, your system
will not work properly... and that’s an absolute fact).
The
lower
connection on the tubes coming thru the block
off assembly is going to be routed to the water outlet on the
intake manifold. Attach your hose with cable clamps on both
ends and route where it will not interfere with linkage or come
in contact with exhaust manifolds or headers.
The
upper
port coming thru the firewall will be routed to and thru your new your electronic water
valve (the water valve is marked for easy installation). First Attach a 6” piece of 5/8” dia. heater hose
with the supplied worm gear clamp. Attach to the inlet side of
the water valve using another supplied hose clamp. Attach a
heater hose from the outlet side of the electronic water valve
and route to the connection on the water pump.
Insert a 6" piece of the clear, 1/2" drain tube we included
through the hole previously drilled and attach over the drain
nipple. Seal around tube with refrigerant tape (see figure 26).
In
Bag Kit C
you’ll find the firewall block off. Install this over the hose connections coming
thru the firewall within the engine compartment. Attach with two #10 - 16 x 3/4" Tek screws
(see figure 25).
TIP: This would be a good time to “jump” ahead a bit, and remove the
ORANGE cable from Bag Kit D and route it thru the block off plate (it will be plugged
into the electronic water valve). The cable for the electronic water valve can share
the hole with smaller liquid line opening.
Seal around the tubes with the included
refrigerant tape. This will keep unwanted moisture and debris from entering thru the firewall...
so seal carefully and thoroughly.
IMPORTANT
NOTICE: PROPER
INSTALLATION OF
WATER VALVE
INSTRUCTIONS!!!
FIGURE 26
Refrigerant Tape
1/2" Clear Drain Tube
Содержание 1971-1973 Mustang A/C system
Страница 1: ...Installation Manual 1971 1973 Mustang DOCUMENT 1 2028 2013 ClassicAutoAir 2 1vs b...
Страница 2: ......
Страница 12: ...12...
Страница 38: ...38...