14
English
DC Current
Range
Resolution
Accuracy
600.0 µA
0.1 µA
±(1.0 % + 3)
6000 µA
1 µA
±(1.0 % + 3)
60.00 mA
0.01 mA
±(1.0 % + 3)
600.0 mA
0.1 mA
±(1.0 % + 3)
6.000 A
0.001 A
±(1.2 % + 5)
10.00 A
0.01 A
±(1.2 % + 5)
Overload protection: 600 Vrms 10 A
Capacitance
Range
Resolution
Accuracy
9.999 nF
0.001 nF
[ REL ] activated: ±(4 % + 10)
99.99 nF
0.01 nF
±(4 % + 5)
999.9 nF
0.1 nF
±(4 % + 5)
9.999 µF
0.001 µF
±(4 % + 5)
99.99 µF
0.01 µF
±(4 % + 5)
999.9 µF
0.1 µF
±(4 % + 5)
9.999 mF
0.001 mF
±10 %
Overload protection: 600 V PTC
When measuring capacitance ≤ 200 nF, you should use the [ REL ] function.
Continuity and Diode
Range
Resolution
Accuracy
0.1 Ω
An open circuit with a resistance > 50 Ω does
not activate the buzzer. A closed circuit with
a resistance
≤ 10
Ω activates the buzzer.
0.001 V
Open circuit: 2.1 V, test current approx. 1 mA.
The normal value for a silicon P–N junction is
approx. 0.5–0.8 V.
Overload protection: 600 Vrms
Resistance
Range
Resolution
Accuracy
600.0 mV
0.1 mV
±(0.7 % + 3)
6.000 V/6000 mV
0.001 V/1 mV
±(0.5 % + 2)
60.00 V
0.01 V
±(0.7 % + 3)
600.0 V
0.1 V
±(0.7 % + 3)
Overload protection: 600 Vrms AC