12
English
Replacing the fuses
If you replace one or both of the fuses, make sure that the replacement fuse is
the correct type and rating.
When
appears on the display and the buzzer sounds, it is time to check
the fuses.
1. Disconnect the test leads from
the multimeter.
2. Turn the function selector switch to OFF.
3. Remove the protective plastic cover.
4. Unscrew the two screws holding the back
panel and remove it.
5. Replace the fuse/fuses with equivalent fuses
to the one/s you remove:
-
1 × 10 A, 600 V, BFC (fast-blow
ceramic), 6 × 25 mm
-
1 × 600 mA, 600 V, BFC (fast-blow
ceramic), 6 × 32 mm
6. Put the battery cover back on and tighten the screws.
Responsible disposal
This symbol indicates that the product should not be disposed of
with general household waste. This applies throughout the entire EU.
In order to prevent any harm to the environment or health hazards
caused by incorrect waste disposal, the product must be handed in
for recycling so that the material can be disposed of in a responsible
manner. When recycling your product, take it to your local collection
facility or contact the place of purchase. They will ensure that
the product is disposed of in an environmentally sound manner.
Specifications
Power supply
2 × AAA/LR03, 1.5 V batteries
Fuses
1 × 10 A, 600 V, BFC (fast-blow ceramic), 6 × 25 mm
1 × 600 mA, 600 V, BFC (fast-blow ceramic), 6 × 32 mm
Test leads
Test leads with probes included
Operating environment
0–40 °C (32–104 °F)
0–30 °C, ≤75 % humidity
30–40 °C, ≤50 % humidity
Storage environment
−10 to +50 °C (14−122 °F)
Max operating altitude
2000 m
Dimensions
155 × 76.5 × 49 mm
Screen size
56.8 × 36.1 mm
Weight
255 g (incl. batteries)