13
English
Technical specifications
Measuring range
Manual selection
Battery tester
1.5 V and 9 V
Diode test
Continuous buzzer
NCV
Backlit display screen
[ Hold ] saves the reading
Low battery warning
Battery symbol is shown on the display
Overload indication
(overload) is shown on the display
DC Voltage
Range
Resolution
Accuracy
600.0 mV
0.1 mV
±(0.7 % + 3)
6.000 V / 6000 mV
0.001 V / 1 mV
±(0.5 % + 2)
60.00 V
0.01 V
±(0.7 % + 3)
600.0 V
0.1 V
±(0.7 % + 3)
Input impedance: Approximately 10 MΩ.
The readings might fluctuate when measuring mV if there is no current in the circuit.
The reading will stabilise once the circuit has current. Accurate to the least significant
digit ≤ ± 3.
Max input voltage: ± 600 V, when the voltage exceeds 610 V,
appears on
the display and the buzzer sounds. Overload protection: 600 Vrms DC
AC Voltage
Range
Resolution
Accuracy
600.0 mV
0.1 mV
±(1.0 % + 3)
6.000 V / 6000 mV
0.001 V / 1 mV
±(0.7 % + 2)
60.00 V
0.01 V
±(1.0 % + 3)
600.0 V
0.1 V
±(1.2 % + 3)
Overload protection: 600 Vrms AC