4
E
n
g
li
s
h
1. Description
• Advanced True RMS clamp-on meter
• AC, DC, capacitance, resistance and frequency measurements, diode test
and buzzer
• Automatic shut-off
• Rubber-clad shock-absorbent casing
• Comes with test leads and 9 V battery
• Max jaw opening 28 mm
• Size 208 × 76 × 30 mm
2. Safety instructions
• This meter is designed and tested to conform to IEC 61010–1, installation
category (overvoltage category) II 600 V, III 300 V and pollution category II.
• This meter conforms to the following EMC Directives: 89/336/EEC
(EMC November 1992, electromagnetic compatibility), Low-Voltage Directive
73/23/EEC, EN61010-1 (04, 93).
• This meter is designed for indoor use at working temperatures in the range
of 0–40 °C.
• Read all the safety information and operating instructions and only use the meter
as specified in this manual.
• Do not use this meter if it or the test leads appear to be damaged, or if you
suspect that the meter might not work properly.
• Make sure that your fingers are behind the finger guards when using the test leads.
• Make sure that the power is turned off before working on the power circuit as
even small currents can be dangerous.
• Do not measure voltages over 600 V DC or 600 V AC RMS between a power
point and earth connection.
• To avoid shocks you need to be CAREFUL when you work with voltage higher
than 60 V DC or 30 V AC RMS. Voltages higher than this pose a risk of heavy
electric shocks.
• Set the rotary selector switch to the correct range and function before starting to
take readings. The function must not be changed during a measurement.
• Never use the meter if the battery cover or battery compartment is open.
• To avoid electric shocks and damage to the meter, do not exceed the meter’s
overload limits. The guarantee will not apply if the meter is used incorrectly.
• This meter is protected by fuses, but they will not protect the meter from all
kinds of misuse.
• The meter must not be used in humid, explosive or flammable environments or
close to strong magnetic fields.
• Replace the battery immediately if the battery warning symbols appears on
the display. A weak battery can cause incorrect results and thereby pose