International
10
Attention: The control cable must be exactly lead through the grooves of
the guiding rollers under the posts. Before using the lift for the first time,
check the position of the control cable again!
After adjusting, the function of the switch system is verified by manually lifting
one of the carriages and pushing the upper limit switch. After the adjustment
has been completed, the tension of the V-belts is checked and adjusted as
required. The power cable is a five-core cable. The connection is made in
the control box: connect the three phase conductors to points 4, 6, 14 of
selector Q, the neutral conductor to point 16, the protective earth conductor
to the cover of the control box. The connection is made over a five-core
cable with a diameter of 2.5 mm, the main fuse must have a rating of 20 A.
The electric motor direction of rotation must be checked. If connected
correctly, the carriages move in accordance with the symbols.
After the connection has been completed, carry out lifting and lowering
cycles to check the function of the switch system and the free movement of
the carriages. It must be checked whether the spindles move the felt inserts
serving their lubrication further down after the lower limit switch has been
actuated (after the carriages have come to a halt). Then, the oil tanks must
be filled with oil according to Table 1. The required oil volume per tank is
about 0.08 l. The manufacturer equips the unit with pre-soaked felt inserts.
Switch off the power supply. Fit the dismantled cover plates again. Then
assemble the swivel arms and the swivel arm locks to the carriages.
Test run without load
Switch the lift on using the selector switch. The lifting without load is initiated
by selecting switch position “Up”. If the lift should now move downward, the
electrical connection was made wrong. Change poles immediately! The
carriages move upward until they reach the upper limit of travel. After the
upper limit of travel has been reached, the lift will not move any more if switch
position “Up” is selected. By selecting switch position “Down” the carriage
moves downward until it reaches the lower limit of travel. When the lower
limit of travel has been reached, the switch position “Down” has no effect
any more. Only after 4 – 5 lifting processes without load, the first test under
load can be performed.
Test run under load
After the lifting cycles without load have been completed, a vehicle with a
weight of about 1,300 kg is driven on the lift to carry out a further 4 – 5 lifting
cycles. If no unusual phenomena can be observed, further run-in cycles are
required.
Содержание Strong-Arm CPL30T
Страница 2: ...International 2...
Страница 22: ...International 22 Figure 1 MAIN COMPONENTS...
Страница 23: ...International 23 Figure 2 DIMENSIONS...
Страница 24: ...International 24 Figure 3 GROUND PLAN DIMENSIONS SWIVEL RANGE...
Страница 25: ...International 25 Figure 4 CIRCUIT DIAGRAM...
Страница 26: ...International 26 Figures 5 6 CONTROL BOX CONTROL CABLE...
Страница 27: ...International 27 Figure 7 POWER SUPPLY 1...
Страница 28: ...International 28 Figure 8 CONTROL ROD...
Страница 29: ...International 29 Figure 9 OIL TANK for spindle lubrication...
Страница 30: ...International 30 Figure 10 SUPPORTING SAFETY NUT...
Страница 31: ...International 31 Figure 11 CARRIAGE...
Страница 32: ...International 32 CARRIAGE Figure 12...
Страница 33: ...International 33 Figure 13 SWIVEL ARM SHORT...
Страница 34: ...International 34 Figure 14 SWIVEL ARM LONG...
Страница 35: ...International 35 Figure 15 PARTS DIAGRAM...
Страница 40: ...International 40...