OPERATION & MAINTENANCE

INSTRUCTIONS

LS1216

Original Instructions

AIR COMPRESSOR

ELECTRIC MOTOR DRIVEN

Содержание PE11C50

Страница 1: ...OPERATION MAINTENANCE INSTRUCTIONS LS1216 Original Instructions AIR COMPRESSOR ELECTRIC MOTOR DRIVEN...

Страница 2: ...Mean Value dB LAeq A Weighted Sound Power Level Calculated Sound Power Level K Declared Single Number Noise Weight SE15 100 PSI 1m 1 28 x 0 40 x 0 81 82 96 5 2 5 dB 99 66 kg PE15 100 PSI 1m 0 95 x 0 4...

Страница 3: ...omer is taking on the obligation to deal with the WEEE in accordance with the WEEE regulations in relation to the treatment recycling recovery and environmentally sound disposal of the WEEE In effect...

Страница 4: ...sor on a firm flat surface with AVMs and ensure an adequate supply of clean air is available to the pump unit 10 Do not exert any strain on electrical cables and ensure that air hoses are not tangled...

Страница 5: ...und the machine 5 The power cable from the main supply must be large enough to carry the starting and running load of the electric motor This is particularly relevant if the compressor is some distanc...

Страница 6: ...SUGGESTED FUSE RATINGS LUBRICATION Pump Use Clarke compressor oil as indicated on machine plate MOTOR SIZE SINGLE PHASE MOTOR D O L THREE PHASE MOTORS 415V KW HP DOL STAR DELTA 0 75 1 0 13 amp 10 amp...

Страница 7: ...ed on machine plate if the pressure exceeds the maximum working pressure stated stop the machine see below vent the system and contact the Clarke Service Department TO STOP COMPRESSOR 1 Switch off at...

Страница 8: ...d be made to this component The ASD should be connected to a 3 phase supply by a qualified electrician 1 Air Compressor Pump 9 Inspection Plug 17 2 Electric Motor or 10 Non Return Valve 18 3 Wire Guar...

Страница 9: ...ge of airline accessories is available from your local CLARKE stockist OVERLOAD BUTTON SINGLE PHASE ONLY The electric motor is fitted with an automatic overload detector which will stop the motor if a...

Страница 10: ...will not start automatically Fault in electrical installation Let an electrician check electrical installation Current supply failure Voltage drop Motor starter faulty Motor incorrectly connected or f...

Страница 11: ...se Tighten Bolts V Belt flywheel or cooling coil touching belt guard Find place of contact and remedy fault Flywheel loose Tighten flywheel Unit installed on an unsuitable base Move unit to a more sol...

Страница 12: ...possible at suction intake or the air being taken in is too warm Ensure unobstructed air flow around the unit Pressure gauge defective Unit too small in relation to air consumption of connected equipm...

Страница 13: ...e air delivered Sump over full Reduce oil to correct level Cylinder worn Contact Clarke Service Intake air filter blocked Change air filter Condensation in crank case especially in 2 stage compressors...

Страница 14: ...IST DAILY WEEKLY 6 MONTHLY NOTES Oil level Check Change Air Receiver Drain Intake Filter Check Clean Replace if necessary Oil breather Check Clean Fan and cooling fins Clean Inlet and outlet valves If...

Страница 15: ...15 Parts Service 020 8988 7400 E mail Parts clarkeinternational com or Service clarkeinternational com DECLARATION OF CONFORMITY...

Страница 16: ......