MAINTENANCE
CHANGING THE SAW BLADE
Only install the correct saw blade. Do not use excessively worn blades. The
maximum rotation speed of the saw must not exceed that of the saw blade.
1. Begin with the saw head in the
raised position and with the slide
rails locked.
2. Move the
blade guard release
lever allowing the blade guard to
be rotated back in the usual way.
Lift the fulcrum plate upwards
releasing the moving guard
assembly to rise upwards.
• The centre screw should now
be accessible below the moving guard.
3. Press and hold down the blade lock, then using the Hex wrench supplied,
undo and remove the centre screw.
• The screw has a
LEFT HAND THREAD (turn it CLOCKWISE to undo).
4. Pull off the outer disc (marked with an ‘O’) followed by the saw blade.
NOTE:
You should take this opportunity to thoroughly clean parts previously
inaccessible.
5. Replace the blade, ensuring it has the correct diameter and bore.
•
Ensure also that all parts are perfectly clean and the blades’ teeth point
down at the front as shown in the picture above.
•
The blade must be rated to at least 6000 rpm.
•
Please note that spare blades are available from Clarke International.
Please see your Clarke dealer.
WARNING: MAKE SURE THAT THE SAW IS SWITCHED OFF AND UNPLUGGED
FROM THE MAINS SUPPLY BEFORE FITTING OR REMOVING THE BLADE.
WARNING: THE BLADE MUST BE RATED TO AT LEAST 6000 RPM.
WARNING: NEVER PUSH THE BLADE LOCK IN WHEN THE MOTOR IS
RUNNING.