![Clarke 6261525 Скачать руководство пользователя страница 4](http://html1.mh-extra.com/html/clarke/6261525/6261525_operation-and-maintenance-instructions-manual_2614480004.webp)
4
Parts & Service: 020 8988 7400 / E-mail: [email protected] or [email protected]
ELECTRICAL CONNECTIONS
Connect the three core mains cable to a suitable industrial supply isolator, or
heavy duty plug meeting the requirements of BS EN 60309. This charger must
be connected to a supply having a rated capacity of greater than 16 Amps.
A normal 13 Amp (BS1363) plug must
NOT
be used.
NOTE: The maximum input current for this unit is 47 amps.
WARNING: THIS APPLIANCE MUST BE EARTHED.
IMPORTANT: The wires in this mains lead are coloured in accordance with
the following code:
GREEN AND YELLOW
-
EARTH (E)
BLUE
-
NEUTRAL (N)
BROWN
-
LIVE (L)
As the colours of the flexible cord of this appliance may not correspond with
the coloured markings identifying terminals, proceed as follows:
• Connect GREEN AND YELLOW coloured cord to terminal marked letter
“E” or Earth Symbol
or coloured Green and Yellow.
• Connect BROWN cord to terminal marked letter ‘L’ or coloured Red.
• Connect BLUE cord to terminal marked letter “N’ or coloured Black.
WARNING: READ THE ELECTRICAL SAFETY INSTRUCTIONS THOROUGHLY.
WARNING: A 13 AMP (BS1363) PLUG IS NOT SUITABLE.
WARNING: THIS APPLIANCE MUST BE EARTHED.
Содержание 6261525
Страница 24: ......