4. Temporarily put the handle back onto the valve and rotate to the closed position and remove the ball
mechanism by sliding it off of the stem through the process opening.
5. If you wish to replace or remove the internal ballcheck, remove the ball retainer clip. If not continue
to step 6.
6. Remove upstream seat, and seal from the inside of the valve.
7. Remove gland follower by taking off the four nuts shown in the picture below, also remove the gland
ring. Pull out the -3- stem packing rings packing rings and discard.
Seat Seal
Upstream Seat
Discarded Packing
Gland Ring