7. Place the new spiral-wound gasket on the underside of the inlet gland like shown. Place the new
upstream seat and seal into the inlet gland opening.
8. Insert the inlet gland assembly from the previous step into the valve as shown.
9. Secure valve into a vice with the large compression nut facing upward. Using a large calibrated
torque wrench, tighten compression nut to 500 Ft-Lbs. Install anti-rotation pin to lock nut in place.
The valve is now ready to be hydro-tested.
Inlet Gland
Spiral-Wound
Gasket
Seat Seal
Upstream Seat