804984 - SP_Zip KXF 2.1 Feinfilter - 11.22 v1.0
Seite 5 von 16
5. Filterdaten - 0.2 Micron
* Der Begriff “bakteriostatisch” bedeutet, dass das System den
Durchgang oder das Wachstum von Bakterien, die möglicherweise
bereits im einströmenden Wasser vorhanden sind, begrenzt. Er
bedeutet nicht, dass das Wasser welches das System verlässt,
sicherer zu trinken ist als das Wasser, das in das System eintritt.
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value
‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 – AESTHETIC EFFECTS
Chlorine
2.0 mg/L ± 10%
2 mg/L
4 mg/L /
5 mg/L
≥ 50%
0.05 mg/L
97.4%
Particulate Class I
particles 0.5 to <5μm
at least 10,000
particles / mL
6,433,333/L
≥ 85%
47,388/L
99.3%
Bacteriostatic
Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 – HEALTH EFFECTS
Cyst
Minimum 50,000 / L
99.9% /
<1/100 L
99.95%
99.99%
Lead 8.5
0.15 mg/L ± 10%
0.155 mg/L
0.015 mg/L /
0.01 mg/L
0.010 mg/L
0.001 mg/L
98.9%
Lead 6.5
0.15 mg/L ± 10%
0.147 mg/L
0.015 mg/L /
0.01 mg/L
0.010 mg/L
0.0005 mg/L
99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1Z-LS, ZENITH 1NZ-LS, BIRKO 1.5B-LS, ZIP 1.5Z-LS,
ZENITH 1.5NZ-LS, ZIP 2Z-LS, ZENITH 2NZ-LS, INSTANTA 1.5IN-LS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class
Treatment Type
Function
Pass
I
Microbiological Status
Bacteriostatic
Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II
Microbiological Treatment
II (a) Bacteria Removal
Will remove or inactivate bacteria.
N/A
II (b) Virus Removal
Will remove or inactivate virus.
N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III
Particulate Reduction
Reduces cloudiness.
IV
Taste and Odour Reduction
Reduces tastes and odours.
V
Chemical Treatment
Decreases certain chemicals:
– Lead
Legend:
= Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42 —
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53 —
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush to drain for five (5) minutes at full flow.
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
• Temperature: 35 -100°F (2-38°C)
Model
Flow Rate Capacity
1Z-LS
3.75 Lpm
4163 L
1.5Z-LS
5.678 Lpm
6813 L
2Z-LS
5.678 Lpm
9463 L
1NZ-LS
3.75 Lpm
4163 L
Model
Flow Rate Capacity
1.5NZ-LS
5.678 Lpm
6813 L
2NZ-LS
5.678 Lpm
9463 L
1.5B-LS
5.678 Lpm
6813 L
1.5IN-LS
5.678 Lpm
6813 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000
AS/NZS 3497
WM-0350001
Global-Mark.com.au
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value
‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 – AESTHETIC EFFECTS
Chlorine
2.0 mg/L ± 10%
2 mg/L
4 mg/L /
5 mg/L
≥ 50%
0.05 mg/L
97.4%
Particulate Class I
particles 0.5 to <5μm
at least 10,000
particles / mL
6,433,333/L
≥ 85%
47,388/L
99.3%
Bacteriostatic
Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 – HEALTH EFFECTS
Cyst
Minimum 50,000 / L
99.9% /
<1/100 L
99.95%
99.99%
Lead 8.5
0.15 mg/L ± 10%
0.155 mg/L
0.015 mg/L /
0.01 mg/L
0.010 mg/L
0.001 mg/L
98.9%
Lead 6.5
0.15 mg/L ± 10%
0.147 mg/L
0.015 mg/L /
0.01 mg/L
0.010 mg/L
0.0005 mg/L
99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1Z-LS, ZENITH 1NZ-LS, BIRKO 1.5B-LS, ZIP 1.5Z-LS,
ZENITH 1.5NZ-LS, ZIP 2Z-LS, ZENITH 2NZ-LS, INSTANTA 1.5IN-LS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class
Treatment Type
Function
Pass
I
Microbiological Status
Bacteriostatic
Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II
Microbiological Treatment
II (a) Bacteria Removal
Will remove or inactivate bacteria.
N/A
II (b) Virus Removal
Will remove or inactivate virus.
N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III
Particulate Reduction
Reduces cloudiness.
IV
Taste and Odour Reduction
Reduces tastes and odours.
V
Chemical Treatment
Decreases certain chemicals:
– Lead
Legend:
= Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42 —
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53 —
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush to drain for five (5) minutes at full flow.
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
• Temperature: 35 -100°F (2-38°C)
Model
Flow Rate Capacity
1Z-LS
3.75 Lpm
4163 L
1.5Z-LS
5.678 Lpm
6813 L
2Z-LS
5.678 Lpm
9463 L
1NZ-LS
3.75 Lpm
4163 L
Model
Flow Rate Capacity
1.5NZ-LS
5.678 Lpm
6813 L
2NZ-LS
5.678 Lpm
9463 L
1.5B-LS
5.678 Lpm
6813 L
1.5IN-LS
5.678 Lpm
6813 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000
AS/NZS 3497
WM-0350001
Global-Mark.com.au
BETRIEBSSPEZIFIKATIONEN
• Druckanforderungen: 10 -125 psi (0,7 - 8,6 bar), nicht
schlagend
• Temperatur: 35 -100°F (2-38°C)
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value
‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 – AESTHETIC EFFECTS
Chlorine
2.0 mg/L ± 10%
2 mg/L
4 mg/L /
5 mg/L
≥ 50%
0.05 mg/L
97.4%
Particulate Class I
particles 0.5 to <5μm
at least 10,000
particles / mL
6,433,333/L
≥ 85%
47,388/L
99.3%
Bacteriostatic
Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 – HEALTH EFFECTS
Cyst
Minimum 50,000 / L
99.9% /
<1/100 L
99.95%
99.99%
Lead 8.5
0.15 mg/L ± 10%
0.155 mg/L
0.015 mg/L /
0.01 mg/L
0.010 mg/L
0.001 mg/L
98.9%
Lead 6.5
0.15 mg/L ± 10%
0.147 mg/L
0.015 mg/L /
0.01 mg/L
0.010 mg/L
0.0005 mg/L
99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1Z-LS, ZENITH 1NZ-LS, BIRKO 1.5B-LS, ZIP 1.5Z-LS,
ZENITH 1.5NZ-LS, ZIP 2Z-LS, ZENITH 2NZ-LS, INSTANTA 1.5IN-LS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class
Treatment Type
Function
Pass
I
Microbiological Status
Bacteriostatic
Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II
Microbiological Treatment
II (a) Bacteria Removal
Will remove or inactivate bacteria.
N/A
II (b) Virus Removal
Will remove or inactivate virus.
N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III
Particulate Reduction
Reduces cloudiness.
IV
Taste and Odour Reduction
Reduces tastes and odours.
V
Chemical Treatment
Decreases certain chemicals:
– Lead
Legend:
= Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42 —
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53 —
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush to drain for five (5) minutes at full flow.
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
• Temperature: 35 -100°F (2-38°C)
Model
Flow Rate Capacity
1Z-LS
3.75 Lpm
4163 L
1.5Z-LS
5.678 Lpm
6813 L
2Z-LS
5.678 Lpm
9463 L
1NZ-LS
3.75 Lpm
4163 L
Model
Flow Rate Capacity
1.5NZ-LS
5.678 Lpm
6813 L
2NZ-LS
5.678 Lpm
9463 L
1.5B-LS
5.678 Lpm
6813 L
1.5IN-LS
5.678 Lpm
6813 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000
AS/NZS 3497
WM-0350001
Global-Mark.com.au
LEISTUNG BEI GESUNDHEITSANSPRÜCHEN VON NSF ZERTIFIZIERT
Dieses System wurde gemäß den NSF/ANSI-Normen 42 und 53 auf die Reduzierung der unten aufgeführten Stoffe
geprüft. Die Konzen tration der angegebenen Stoffe im Wasser, das in das System eintritt, wurde auf eine Konzentration
reduziert die kleiner oder gleich dem zulässigen Grenzwert für das Wasser ist, welches das System verlässt. Wie in den
NSF/ANSI-Standards 42 und 53 angegeben.
Das System wurde von NSF International gemäß NSF/ANSI
Standard 42 und 53 auf die Reduzierung von:
STANDARD NR.42 - STANDARD NR.53 -
ÄSTHETISCHE AUSWIRKUNGEN
GESUNDHEITLICHE AUSWIRKUNGEN
Bakteriostatische Wirkungen Chemikalienreduzierung
Chemische Reduktion
Blei
Geschmack & Geruch
Mechanische Filtration
Chlor
Zyste
Mechanische Filtrierung
Nominaler Partikelgehalt Klasse I
AS/NZ
S 3497
WM -0350001
WM -0350001
Global-Mark.com.au
Global-Mark.com.au
FILTER PERFORMANCE DATA SHEET
HEALTH CLAIM PERFORMANCE CERTIFIED BY NSF
This system has been tested according to NSF/ANSI Standards 42 and 53 for
the reduction of the substances listed below. The concentration of the indicated
substances in water entering the system was reduced to a concentration less
than or equal to the permissible limit for water leaving the system, as specified
in NSF/ANSI Standards 42 and 53.
Substance
Influent
Challenge
Concentration
Average
Influent
Concentration
Maximum
Acceptable
Value
‡
Maximum
Permissible Water
Concentration
Reduction
Requirements
Average
Effluent
Concentration
Average
Reduction
STANDARD 42 – AESTHETIC EFFECTS
Chlorine
2.0 mg/L ± 10%
2 mg/L
4 mg/L /
5 mg/L
≥ 50%
0.05 mg/L
97.4%
Particulate Class I
particles 0.5 to <5μm
at least 10,000
particles / mL
6,433,333/L
≥ 85%
47,388/L
99.3%
Bacteriostatic
Unit passes NSF Std. 42 for Bacteriostatic effects.
STANDARD 53 – HEALTH EFFECTS
Cyst
Minimum 50,000 / L
99.9% /
<1/100 L
99.95%
99.99%
Lead 8.5
0.15 mg/L ± 10%
0.155 mg/L
0.015 mg/L /
0.01 mg/L
0.010 mg/L
0.001 mg/L
98.9%
Lead 6.5
0.15 mg/L ± 10%
0.147 mg/L
0.015 mg/L /
0.01 mg/L
0.010 mg/L
0.0005 mg/L
99.3%
*Tested using flow rate = 1.0 gpm; pressure = 60 psig ± 3; pH = 7.5 ± 0.5; temp. = 20° ± 3°C
‡ United States Environmental Protection Agency (USEPA) Safe Drinking Water Act / New Zealand Ministry of Health Drinking-water Standards for New Zealand
ZIP 1Z-LS, ZENITH 1NZ-LS, BIRKO 1.5B-LS, ZIP 1.5Z-LS,
ZENITH 1.5NZ-LS, ZIP 2Z-LS, ZENITH 2NZ-LS, INSTANTA 1.5IN-LS
This appliance meets the domestic water treatment appliance Standards
AS/NZS 3497 and AS/NZS 4348 for the following water process:
Class
Treatment Type
Function
Pass
I
Microbiological Status
Bacteriostatic
Will stop bacteria increasing, but will
not remove unless II(a) is passed.
II
Microbiological Treatment
II (a) Bacteria Removal
Will remove or inactivate bacteria.
N/A
II (b) Virus Removal
Will remove or inactivate virus.
N/A
II (c) Protozoa Removal
Cryptosporidium
and
Giardia.
Will not remove or inactivate bacteria
unless II(a) and II(b) are passed.
III
Particulate Reduction
Reduces cloudiness.
IV
Taste and Odour Reduction
Reduces tastes and odours.
V
Chemical Treatment
Decreases certain chemicals:
– Lead
Legend:
= Pass N/A = Not Applicable
System Tested and Certified by NSF International against
NSF/ANSI Standard 42 and 53 for the reduction of:
STANDARD NO. 42 —
AESTHETIC EFFECTS
Bacteriostatic Effects
Chemical Reduction
Taste & Odor
Chlorine
Mechanical Filtration
Nominal Particulate Class I
STANDARD NO. 53 —
HEALTH EFFECTS
Chemical Reduction
Lead
Mechanical Filtration
Cyst
GENERAL INSTALLATION / OPERATION /
MAINTENANCE REQUIREMENTS
• Install vertically with cartridge hanging down.
• Use minimum length of tubing possible.
• Flush to drain for five (5) minutes at full flow.
• Replace cartridges when capacity is reached or
when flow becomes too slow, but at least annually.
• For cold water use only.
• Product must be installed with a backflow prevention
device in accordance with AS/NZS 3500.1.2 and
AS/NZS 2845.1
OPERATING SPECIFICATIONS
• Pressure requirement: 10 -125 psi
(0.7 - 8.6 bar), non-shock
• Temperature: 35 -100°F (2-38°C)
Model
Flow Rate Capacity
1Z-LS
3.75 Lpm
4163 L
1.5Z-LS
5.678 Lpm
6813 L
2Z-LS
5.678 Lpm
9463 L
1NZ-LS
3.75 Lpm
4163 L
Model
Flow Rate Capacity
1.5NZ-LS
5.678 Lpm
6813 L
2NZ-LS
5.678 Lpm
9463 L
1.5B-LS
5.678 Lpm
6813 L
1.5IN-LS
5.678 Lpm
6813 L
SPECIAL NOTICES
• Installation instructions, parts and service availability, and
standard warranty are included with the product when shipped.
• This drinking water system must be maintained according to
manufacturer’s instructions, including replacement of filter
cartridges.
• Do not use with water that is microbiologically unsafe, or of
unknown quality without adequate disinfection before or after
the system. Systems certified for cyst reduction may be used
on disinfected waters that may contain filterable cysts.
• The contaminants or other substances removed or reduced by
this water treatment system are not necessarily in your water.
• Check for compliance with state and local laws and regulations.
• Tested under standard laboratory conditions as specified
above. Actual performance may vary depending on influent
water conditions.
The term "bacteriostatic" indicates that the system limits the
passage or growth of bacteria that may already exist in the
incoming water. It does not mean that water leaving the system
is safer to drink than water entering the system.
EPA Est. NO. 00263-IL-002
Manufactured for Zip by Pentair Everpure
1040 Muirfield Drive
Hanover Park, IL 60133 USA,
630.307.3000
AS/NZS 3497
WM-0350001
Global-Mark.com.au
Modell
Durchfluss
Kapazität Artikel #
0.2mic KXF 2.1 Feinfilter
1.5S
5.678 l/min
6813 L
93702
Содержание Zip KXF 2.1