Page 6 of 16
804984 - SP_Zip KXF 2.1 Fine filter - 11.22 v1.0
Contents
1. Safety Instructions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 6
2. Exchange of internal filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Change the Filter: . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
3. Inserting & Removing Water Supply Lines from John Guest Fittings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
4. Other information . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
5. Filter Performance Data - 0.2 Micron . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
• Designed for indoor use only.
• Do not install where exposed to direct sunlight or temperatures <4 °C or >40 °C.
• Minimum safe operating water pressure is 70 kPa, maximum 700 kPa.
• Do not install where water quality is unknown or microbiologically unsafe.
• After a period of non-use thoroughly flush the filter or tanks.
• For safety’s sake, replace all filter cartridges at intervals of 12 months or less.
• Replace any filter if water flow slows or if unpleasant tastes or odours occur.
WARNING
To reduce the risk associated with the ingestion of contaminants:
• Do not use with water that is microbiologically unsafe or of unknown quality without
adequate disinfection before or after the system.
CAUTION
To reduce the risk associated with property damage due to water leakage:
• Read and follow Use Instructions before installation and use of this system.
• Installation and use MUST comply with all state and local plumbing codes.
• Protect from freezing, remove filter cartridge when temperatures are expected to
drop below 4.4°C.
• Do not install systems in areas where ambient temperatures may go above 43° C.
• Do not install on hot water supply lines. The maximum operating water temperature of
this system is 38°C.
• Do not use a gas torch or other high temperature sources near system, cartridges, plas-
tic fittings or plastic plumbing.
• Do not install in direct sunlight or outdoors.
• Ensure all tubing and fittings are secure and free of leaks.
• The disposable filter cartridge MUST be replaced every 12 months, at the rated capac-
ity or sooner if a noticeable reduction in flow rate occurs.
1. Safety Instructions
Содержание Zip KXF 2.1
Страница 15: ......