18
19
For installations under difficult conditions, these mounting accessories are available:
Mounting Frame Kit RDX 3
(Art. no. 36100)
The instant water heater can be installed by means of this mounting kit when the
power supply cable is coming out of the wall at any place from behind the unit, or the
wall has unusual surface conditions, making it difficult for installing the water heater.
When using the RDX the protection class changes from IP25 to IP24.
Mounting Accessories
4. Installation
RDX 3
VDX
UDX
Extension Kit VDX
(Art. no. 34120) – RDX is necessary! –
The instant water heater can be installed by means of this extension kit if the water
pipes are coming displaced or exchanged out of the wall or if they are coming edge-
wise on the wall to the unit. The power supply could come out of the wall at any place
under the unit or the wiring could be installed surface-mounted.
Extension Kit UDX
(Art. no. 34110) – RDX is necessary! –
The instant water heater can be installed by means of this extension kit if the water-
connections are expiring above the unit. The power supply could come out of the wall
at any place under the unit or the wiring could be installed surface-mounted.
4. Installation
Installing the Wall Bracket
Note: If you install this instantaneous water heater in exchange for a conventional
instantaneous water heater, there is generally no need to drill holes for the wall brack-
et, in this case step 2 would not be necessary.
Thoroughly rinse the water supply pipes before installation to remove soiling from the
pipes.
1. Using a 12 mm hexagon socket screw key, screw the screw-in nipples into the wall
connections. The seals must be fully screwed into the thread. After tightening, the
double nipples must protrude by 12 – 14 mm.
2. Hold the included mounting template on the wall and align it so that the holes in the
template fit over the double nipples. Mark the drill holes according to the template
and drill them using a 6 mm drill. Insert the included dowels.
3. Pull down the faceplate and unscrew the main hood screw to open the appliance.
4. Loosen the knurled nut to remove the wall bracket and screw the wall bracket to
the wall. Offset tiling or uneven surfaces can be compensated by up to 30 mm with
the aid of the spacers supplied. The spacers are fitted between the wall and the wall
bracket.
Installing Connection Pieces
cold
warm
D
Note: Fasten the screw nuts with caution, to avoid damage to the valves or the piping
system.
1. As shown in the illustration, screw the cold water connection piece with the union
nut and the ½ inch seal onto the cold water connection.
2. Screw the hot water connection piece with the union nut and the ½ inch seal onto
the hot water connection.
3. Put the water flow reducer “D” into the hot water connection piece.
Содержание GERMAN POOL DEN12
Страница 15: ...28 29 3 3 60 C 20 C 60 C 1 C 35 C 43 C 0 5 C 20 C 35 C 38 C 42 C 48 C PIN...
Страница 17: ...32 33 3 USER 4 INFO 70 C 3 1 2 3 4 5 10...
Страница 18: ...34 35 4 DSN PCB PCB 1 2 DEN12 5 1 SDB...
Страница 21: ...40 41 a closed open 1 3 1 2 3 3 8 3 8 4 a 5 4 600x600 5 1 2 1 2 1 2 1 2 D 3 8 3 8 6 1 2 1 2 1 2 D...