![CKD GPS3 Series Скачать руководство пользователя страница 28](http://html1.mh-extra.com/html/ckd/gps3-series/gps3-series_instruction-manual_2611726028.webp)
5.MAINTENANCE
5.1 Periodic inspection
(1) Daily inspection
・Before operating the product, confirm proper operation.
・Before using this product, it is operating correctly, please perform the operation confirmation.
(2) Periodic inspection
・To operate the product in its optimal operating state, carry out the periodic inspection
normally once every six months.
・Check that no leak occurs in the piping.
5.2 Disassembly and reassembly
a) Before disassembling or cleaning the orifice,turn the power OFF, stop the supply
of compressed air and make sure that there is no residual pressure.
b) Do not disassembly the product as it will affect performance.
Read instructions and precautions enclosed with the product before starting use
or disassembly.
5.2.1 Orifice cleaning
It is possible to clean foreign matter accumulated in the internal orifice.
■ Disassembly procedure
1) Please remove the pin from the product body with a thin tool such as a flathead screwdriver.
2) Pull the cartridge fitting and pull it out from the product body.
Pin
Cartridge fitting
CAUTION
WARNING
MAINTENANCE
5
− 27 −
[SM-P00143-A]
Содержание GPS3 Series
Страница 14: ...OPERATION Names and functions of display operation section Setting OPERATION 13 SM P00143 A...
Страница 27: ...Observation 1 R Read only 2 This value is able to be set only in option KA Diagnosis OPERATION SM P00143 A 26...
Страница 32: ...Manifold Unit PRODUCT SPECIFICATIONS 31 SM P00143 A...
Страница 33: ...Dimensions Discrete PRODUCT SPECIFICATIONS SM P00143 A 32...
Страница 34: ...Manifold Unit PRODUCT SPECIFICATIONS 33 SM P00143 A...
Страница 38: ...Technical data Characteristics data short range PRODUCT SPECIFICATIONS 37 SM P00143 A...
Страница 39: ...Characteristics data wide range PRODUCT SPECIFICATIONS SM P00143 A 38...
Страница 40: ...Characteristics data PRODUCT SPECIFICATIONS 39 SM P00143 A...