c) Swarf and grinder chips, etc., could clog the nozzle.Switch the supply pressure
(max. 600 kPa) when transporting the workpiece during machining processes to
prevent the detection nozzle from becoming clogged.
d) Select an output format (NPN, PNP) matching the input unit of the programmable
controller being used.
e) Operation may be disabled if a capacitance load such as an AC/DC buzzer is
connected to the load.A protection circuit is provided to prevent damage from
incorrect wiring or overcurrent. A relay must be used when connecting a
capacitance load.
f) Using the master gauge and gap gauge
・Be careful not to be dangerous as it will be adjusted while operating the machine.
Adjustment is 1) gauge set, 2) machine operation, 3) adjustment of this product,
a total of 3 people are required.
・Clearance cannot be set unless the master gauge or gap gauge is accurately
pressed against the detection nozzle.
g) One detection nozzle can be used for one of these product units.
h) Immediately after work is started, the coolant from the nozzle may accumulate in
the pipe and cause the sensor to turn ON for a short time. Wait for coolant to be
discharged by the detection air before starting the machine.
i) If the nozzle becomes blocked, remove the pipe on this product's side and blow out
stuck foreign matter with an air gun. If foreign matter cannot be removed,
poke a needle, etc., through the detection nozzle on the end.
j) If the output setting value is changed, control system devices could operate
unintentionally.
Stop devices before changing settings.
k) Ensure proper operation through periodic inspections.
CAUTION
PROPER
OPERATION
3
[SM-P00143-A]
− 12 −
Содержание GPS3 Series
Страница 14: ...OPERATION Names and functions of display operation section Setting OPERATION 13 SM P00143 A...
Страница 27: ...Observation 1 R Read only 2 This value is able to be set only in option KA Diagnosis OPERATION SM P00143 A 26...
Страница 32: ...Manifold Unit PRODUCT SPECIFICATIONS 31 SM P00143 A...
Страница 33: ...Dimensions Discrete PRODUCT SPECIFICATIONS SM P00143 A 32...
Страница 34: ...Manifold Unit PRODUCT SPECIFICATIONS 33 SM P00143 A...
Страница 38: ...Technical data Characteristics data short range PRODUCT SPECIFICATIONS 37 SM P00143 A...
Страница 39: ...Characteristics data wide range PRODUCT SPECIFICATIONS SM P00143 A 38...
Страница 40: ...Characteristics data PRODUCT SPECIFICATIONS 39 SM P00143 A...