uTouch User Manual
v1.6
20
8.4
Outputs and relays
On this screen it is possible to set up output and relay behavior.
First, you need to choose the event on the left side of the window, and then select the
output or relay which will activate if selected signal occurs. Saving is done automatically upon value
change. You don't have to press Save button.
Here is an example – how to set up Relay 1 to open for 5 seconds when the unit is tampered
with (tamper switch is activated):
You can set up output and relay behavior for following events:
SYS: Tamper
Tamper switch activation
SYS: Input 4
Activation of input 4
SYS: Input 3
Activation of input 3
SYS: Input 2
Activation of input 2
SYS: Input 1
Activation of input 1
SYS: Entry failed Unsuccessful attempt to enter system settings
SYS: Entry
System settings entered
SYS: Boot
Unit boot process finished
RDC: Verified 2
User verified with card on Wiegand input
RDC: Verified
User verified with card on built-in card reader
RDC: No access
User verified with card, but access is denied
RDC: Error 2
Error reading card on Wiegand input
RDC: Error
Error reading card on built-in card reader
PIN: Verified
Access granted for user when using Pin only
PIN: No access
Invalid access for userwhen using Pin only
PIN: Error
User does not exist / Non-existant Pin
FPM: Verified
User verified with enrolled finger
FPM: No access Access denied for user using fingerprint
FPM: Error
Fingerprint not verified
There are more events like SYS: Alarm 1,2,3,4, SYS: Door forced, long, open, etc. that can
occur if defined so in Events. (See section
12.2
of this manual)