Citrix ADC MPX
The following figure shows the back panel of the MPX 15000 appliance.
Figure 2. Citrix ADC MPX 15000, back panel
The following components are visible on the back panel of the MPX 15000 appliance:
• Two 480 GB or larger removable solid-state drives in a redundant array of independent disks
(RAID) configuration. In a RAID configuration, the same data is stored on multiple drives to im-
prove performance, increase storage capacity, lower the risk of data loss, and provide fault tol-
erance. The two SSDs store the same data. If one fails and you replace it, the new SSD mirrors
the other one.
Note:
Drive densities might increase as components become EOL but its size is never smaller
than the original.
• Power switch, which turns power to the appliance on or off.
–
If the OS is functional, press the switch for less than two seconds to power down the system
with a graceful shutdown.
–
If the OS is not responsive, press the power switch for more than 4 seconds to force the
power off.
• Two hot-swappable, 100–240 VAC input power supply modules, rated at 1000 watts each. Maxi-
mum power consumption is 420 watts and typical power consumption is 310 watts. Each power
supply has an LED indicating its status:
© 1999
‒
2022 Citrix Systems, Inc. All rights reserved.
62
Содержание ADC MPX 5550
Страница 1: ...Citrix ADC MPX Citrix Product Documentation docs citrix com November 17 2022...
Страница 15: ...Citrix ADC MPX 1999 2022 Citrix Systems Inc All rights reserved 15...
Страница 16: ...Citrix ADC MPX 1999 2022 Citrix Systems Inc All rights reserved 16...
Страница 124: ...Citrix ADC MPX Figure 2 Replacing the 1U bezel 1999 2022 Citrix Systems Inc All rights reserved 124...
Страница 132: ...Citrix ADC MPX 1999 2022 Citrix Systems Inc All rights reserved 132...