![Citrix ADC MPX 5550 Скачать руководство пользователя страница 195](http://html1.mh-extra.com/html/citrix/adc-mpx-5550/adc-mpx-5550_manual_2611002195.webp)
Citrix ADC MPX
Health
attributes/-
Platform
SNMP Alarm
Support
MPX
5500/5600
MPX
7500/9500
MPX
9700/10500/12500/15500
MPX
9700/10500/
12500/15500
10G
+5.0 V Supply
(Volts)
No
4.8–5.2
4.8–5.2
4.8–5.2
4.8–5.2
+12.0 V
Supply (Volts)
No
11.5–12.35
11.52–12.35
11.5–12.31
11.8–12.35
-12.0 V Supply
(Volts)
No
- NA -
- NA -
- NA -
- NA -
Battery
(Volts)
No
3–3.5
2.85–3.5
2.85–3.5
2.85–3.5
Intel CPU Vtt
Power (Volts)
No
1–1.2
1–1.2
1–1.2
1–1.2
5 V Standby
(Volts)
No
4.9–5.2
4.9–5.2
4.9–5.2
4.9–5.2
Voltage Sen-
sor2(Volts)
No
1.2–2
1.2–2
1.2–2
1–1.8
CPU Fan 0
Speed (RPM)
Yes
3000–16000
3000–16000
3000–10000
3000–16000
CPU Fan 1
Speed (RPM)
Yes
3000–16000
3000–16000
3000–16000
3000–16000
System Fan
Speed (RPM)
Yes
900–15000
900–13000
900–10000
900–9000
System Fan 1
Speed (RPM)
No
900–15000
900–15000
900–10000
900–8000
System Fan 2
Speed (RPM)
No
900–15000
900–15000
900–10000
900–10000
CPU 1
Temperature
Yes
24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
CPU 0
Temperature
Yes
24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
24–90
(Celsius),
75.2–194
(Fahrenheit)
© 1999
‒
2022 Citrix Systems, Inc. All rights reserved.
195
Содержание ADC MPX 5550
Страница 1: ...Citrix ADC MPX Citrix Product Documentation docs citrix com November 17 2022...
Страница 15: ...Citrix ADC MPX 1999 2022 Citrix Systems Inc All rights reserved 15...
Страница 16: ...Citrix ADC MPX 1999 2022 Citrix Systems Inc All rights reserved 16...
Страница 124: ...Citrix ADC MPX Figure 2 Replacing the 1U bezel 1999 2022 Citrix Systems Inc All rights reserved 124...
Страница 132: ...Citrix ADC MPX 1999 2022 Citrix Systems Inc All rights reserved 132...