Citrix ADC MPX
Hardware health attributes
July 27, 2022
Operating ranges for Citrix ADC hardware platforms vary for different attributes.
Note
Use the
stat system
-
detail
command to display the current values of the attributes.
Health attributes for the MPX 9100 platform
The following table lists the health attributes for the MPX 9100 platform.
Health Attribute
Recommended Range
CPU Temp (Celsius)
10–95
PCH Temp (Celsius)
10–85
System Temp (Celsius)
10–80
Peripheral Temp (Celsius)
10–80
CPU_VRMIN Temp (Celsius)
10–95
VRMABCD Temp (Celsius)
10–95
VRMEFGH Temp (Celsius)
10–95
DIMMABCD Temp (Celsius)
10–80
DIMMEFGH Temp (Celsius)
10–80
System Fan 1 Speed (RPM)
1300–18000
System Fan 2 Speed (RPM)
1300–18000
System Fan 3 Speed (RPM)
1300–18000
System Fan 4 Speed (RPM)
1300–18000
System Fan 5 Speed (RPM)
1300–18000
System Fan 6 Speed (RPM)
1300–18000
Standby 3.3 V Supply (Volts)
2.885–3.69
+5.0 V Supply (Volts)
4.466–5.737
+12.0 V Supply (Volts)
10.704–13.476
VBAT (Volts)
2.591–3.464
© 1999
‒
2022 Citrix Systems, Inc. All rights reserved.
185