No.
Signal
Function
1
FG
Frame ground
2
DRAWER1
Cash drawer 1 drive signal
3
DRSW
Cash drawer switch input
4
VDR
Cash drawer drive power supply
5
DRAWER2
Cash drawer 2 drive signal
6
GND
Signal ground (common ground on circuits)
* Applicable connector: RJ-11
(2) Electric characteristics
1) Drive voltage: 24 VDC
2) Drive current: Approx. 1 A max. (not to exceed 510 ms.)
3) DRSW signal: Signal levels: “L” = 0 to 0.5 V, “H” = 3 to 5 V
(3) DRSW signal
Status can be tested by commands.
(4) Drive circuit
Cash drawer kick-out connector
Cash drawer
open/close
switch
Shielded
Printer
Cash drawer
CAUTION
n
Cash drawers 1 and 2 cannot be operated at the same time.
n
The solenoid used for the cash drawer should be 24 Ω or more. Do not allow the electric cur-
rent to exceed 1 A. Excessive current could damage or burn out the circuits.
– 62 –