Intruder alarm system

Operating
Instructions

Key

These operating
instructions cover the
following intruder
system:

ÿ

8EP 394 XR1G3
panel with built in
keypad

For Clarity, the
information given on
setting the system,
assume that all Programs
use a timed or final door
setting routine.

Unset system indications

An unset system will have both Day and Power

indicators lit. This is a normal
indication when the system is
disarmed.

Note:

If the Power indicator goes off at

any time then there is a mains supply
failure at the security panel, consult your
servicing organisation.

Set System indication

An active ‘Set’ system will have only the Power

indicator lit. This is an armed
system indication.

4188 693 issue 1 8/01

1

Unset

system

indications

Power

0

1

2

3

5

6

7

8

Chime

Omit

Reset

4

9

Set

Prog

PA

Attack

Tamper

Day

1 2 3 4 5 6 7 8

8EP 394 XR1 G3 panel
with built-in keypad

Power

/!

mini

0

1

2

3

5

6

7

8

h m

mi

R s t

4

9

S t

P o

A

A tack

Tamper

Day

1 2 3 4 5 6 7 8

LED steady On indication

LED Off

Strobe

Bell

NOTE: In general a flat beep is
an indication of an incorrect key press.

Sound description

Internal sound

External devices

LED flashing indication

Day

Power

Power

XR1

 

 

www.ukpanels.com

Содержание XR1 G3

Страница 1: ...ns supply failure at the security panel consult your servicing organisation Set System indication An active Set system will have only the Power indicator lit This is an armed system indication 4188 69...

Страница 2: ...arm all of the zones and become Set as the user leaves the property and closes the final door Program 2 To protect the perimeter of the property in the evening and become Set after say 20 seconds Pro...

Страница 3: ...r when you try to Set it the sounder will produce an open zone tone and the fault will be displayed Either re enter your code to turn off and investigate or omit the faulty zone s from the system How...

Страница 4: ...is Unset When a zone that is set to chime is operated the internal sounder will produce a low volume two stage warning tone and the Zone indicator will show The indicator may be cancelled by pressing...

Страница 5: ...ll starts with the newest event number 8 to the oldest one number 1 4188 693 issue 1 8 01 5 Citadel XR1 G3 intruder system Operating instructions Operator s Program mode Reset Quit the current functio...

Страница 6: ...ZONE 1 4 Rising beeps Attack Leave program mode Day Tamper Attack Acknowledge NOTE The sounder will produce a flat beep if code is rejected Enter Operator s program mode Example To create user 2 code...

Страница 7: ...m 4188 693 issue 1 8 01 7 Citadel XR1 G3 intruder system Operating instructions How to carry out Alarm and Walk tests Reset Reset Alarm test 0 Attack x1 for zone 1 x2 for zone 2 x4 for zone 4 flat x1...

Страница 8: ...m or Set a Program and while the system is setting ZONE S TO BE ARMED n Press the zone s to be omitted ZONE S TO BE OMITTED Exit beep Exit beep 10 seconds insistent beeps Day To exit Operator s progra...

Отзывы: