How to carry out Alarm and Walk

tests

The alarm test function
allows you to test the
Strobe, Bell, Low and
High volume sounders
of the system.

The walk test function
allows each detector to
be checked in order to
verify that they are
functioning correctly.

Servicing

organisation details

Servicing organisation name:

Telephone number:

Date of installation:

Account Number:

Installation Date:

Bell Time:

Bell delay

Area
protected

Program
1

Program
2

Program
3

Zone 1

Zone 2

Zone 3

Zone 4

Zone 5

Zone 6

Zone 7

Zone 8

T

Timed (Entry/Exit Zone)

TI

Time Inhibited (Access zone to keypad)

I

Immediate

(All zones armed to give full alarm)

4188 693 issue 1 8/01

7

Citadel XR1 G3 intruder system

Operating instructions

How

to

carry

out

Alarm

and

Walk

tests

Reset

Reset

Alarm test

0

Attack

x1 for zone 1
x2 for zone 2

|

x4 for zone 4
flat x1 for zone 5
flat x2 for zone 6

|

flat x4 for zone 8

Rapid for PA

Rapid for Tamper

Zones

Strobe

Strobe test

2

Bell test

3

Low volume
sounder

High volume
sounder

4

5

Walk test

6

Strobe On

Bell on

internal low
volume sound

internal high
volume sound

Strobe On

Day

Day

Day

Day

Day

OFF

0

Day

Exit current level

Leave program mode

Day

Tamper

Attack

Acknowledge

Appropriate zone lights
are lit(latched)

Attack

Tamper

Press zero to turn off
options 2,3,4 and 5
before selecting a new one

Enter Operator’s program mode

Example: To start bell test and thereafter to stop bell test.

3

Prog

0

1

2

3

0

Reset

0

Reset

www.ukpanels.com

Содержание XR1 G3

Страница 1: ...ns supply failure at the security panel consult your servicing organisation Set System indication An active Set system will have only the Power indicator lit This is an armed system indication 4188 69...

Страница 2: ...arm all of the zones and become Set as the user leaves the property and closes the final door Program 2 To protect the perimeter of the property in the evening and become Set after say 20 seconds Pro...

Страница 3: ...r when you try to Set it the sounder will produce an open zone tone and the fault will be displayed Either re enter your code to turn off and investigate or omit the faulty zone s from the system How...

Страница 4: ...is Unset When a zone that is set to chime is operated the internal sounder will produce a low volume two stage warning tone and the Zone indicator will show The indicator may be cancelled by pressing...

Страница 5: ...ll starts with the newest event number 8 to the oldest one number 1 4188 693 issue 1 8 01 5 Citadel XR1 G3 intruder system Operating instructions Operator s Program mode Reset Quit the current functio...

Страница 6: ...ZONE 1 4 Rising beeps Attack Leave program mode Day Tamper Attack Acknowledge NOTE The sounder will produce a flat beep if code is rejected Enter Operator s program mode Example To create user 2 code...

Страница 7: ...m 4188 693 issue 1 8 01 7 Citadel XR1 G3 intruder system Operating instructions How to carry out Alarm and Walk tests Reset Reset Alarm test 0 Attack x1 for zone 1 x2 for zone 2 x4 for zone 4 flat x1...

Страница 8: ...m or Set a Program and while the system is setting ZONE S TO BE ARMED n Press the zone s to be omitted ZONE S TO BE OMITTED Exit beep Exit beep 10 seconds insistent beeps Day To exit Operator s progra...

Отзывы: