How to Quick set
During the exit period (on entering User code)
the system may be Set
quickly by pressing Set.
This removes the exit time
period.
If you omit zones and
require Quick Set, you will
need to press Set twice.
How to Omit zone(s) on setting
system
During the exit period after entering User code
and selecting a
program press
OMIT, the exit
tone will stop and
zones that are
about to be armed
will be displayed.
Key in the zone
number(s) to be
omitted which will
flash to confirm
selection. Zone
indicators which
show steady are
still about to be
armed. When the
selection is
complete press Set
and the exit tone
will start.
If a zone refuses to be omitted, it may be
because the engineer has programmed the panel
to prevent you from turning off the zone. If in
doubt ask your installer for advice.
Fire Alarm
The fire zone will operate on detection of a fire,
whether the system is Set or Unset, when
configured as a 24 hour zone, and cause a
distinctive internal sounder tone. The external
sounders will pulse on and off at 2 second
intervals and zone indicator will flash to attract
attention.
How to set Chime Zones
Chime is a low security monitoring system for
use when the system is Unset. When a zone that
is set to chime is operated, the internal sounder
will produce a low volume two stage warning
tone and the Zone indicator will show. The
indicator may be cancelled by pressing Reset.
Chime is particularly useful in a shop to warn of
a customer presence or in a house to warn that a
door or particular area has been accessed.
Any zone may set to be on or off chime by
pressing the CHIME key and then keying in the
required zone number(s). Key 0 to cancel all
zones from chime. After a few seconds the
system will automatically return to the Day
mode.
4
4188 693 issue 1 8/01
Operating instructions
Citadel XR1 G3 Intruder system
How
to
Quick
set
Chime
Reset
Day
Day
Timeout after 5 seconds if
no selection is made
Chime
5
6
7
2
3
4
1
8
Press
number
button
to
select
/
deselect
Zone
Chime
0
Deselect all zones
(Factory default no chime)
Zone n
Chime selected
Zone n
Chime deselected
Zone 1
Zone 2
Zone 3
Zone 4
Zone 5
Zone 6
Zone 7
Zone 8
Appropriate
Zone indicator
is lit to show
chime zone(s)
Leave chime mode
Day
Example: To set zone 3 and 4 to
chime, Press:
Chime
3
4
Reset
Set
Set the system or
Set a Program
Day
Day
5 seconds
insistent beeps
Set
Omit
Day
Set the system or
Set a Program and while the
system is setting:
ZONE(S) TO BE ARMED
n
Press the zone(s)
to be omitted
ZONE(S) TO BE OMITTED
Exit beep
Exit beep
10 seconds
insistent beeps
Day