background image

How to set the system (on

program 1)

The green Day indicator should be showing.

Enter your code
number and check
that the system is
clear (none of the
zone indicators
are showing). The
sounder will now
produce an exit
beep tone and you
should leave by
the approved
route. The system
will Set as the
beep tone stops.

Push to Set Switch

In some systems a Push to Set switch may be
fitted outside the premises near to the main exit
door. This should be used to complete the setting
procedure once the building has been vacated.
As the switch is operated, the exit beep tone will
stop and a chime tone will be produced to
acknowledge setting.

Keyswitch Set

Your system may have been fitted with a remote
keyswitch. This can be used as an alternative to
arming the system with a code and will set
Program 1.
Where a keyswitch is used it may be necessary
on occasions to allow it to catch up with the
system. For example if the alarm was set with a
code, to Unset with the keyswitch, it would have
to be momentarily turned to Set then returned to
Unset.

Faults during setting

If the system is not clear when you try to Set it,
the sounder will produce an open zone tone and
the fault will be displayed. Either re enter your
code to turn off and investigate or omit the faulty
zone(s) from the system.

How to unset the system (turn

off)

On entering the premises an entry beep tone
come on. Enter your code, the green Day
indicator is lit. The system is unset and
disarmed.

How to set program 1,2 or 3

The green Day indicator should be showing.

Enter your code
number and the
exit beep tone
will start. Press
the Prog key and
the exit tone will
stop. Press 1, 2
or 3 for the
required
program, the
sounder will
beep to
acknowledge the

program number. The exit beep tone will start
and you should leave by the approved route. The
system will Set as the beep tone stops.

It is important that you follow the correct
procedure when setting the system. After leaving
the protected area it is absolutely essential that
you wait until the exit tone stops, before
assuming the system has set.

4188 693 issue 1 8/01

3

Citadel XR1 G3 intruder system

Operating instructions

How

to

set

the

system

(on

program

1)

n

n

n

Day

Day

10seconds
insistent beeps

Exit beep

n

n

n

n

n

Day

Day

Acknowledge

Entry beep

Prog

n

n

n

n

Day

3

2

1

Or

Day

Exit beep

Exit beep

10 seconds
insistent beeps

ZONE 1-3

Exit beep

www.ukpanels.com

Содержание XR1 G3

Страница 1: ...ns supply failure at the security panel consult your servicing organisation Set System indication An active Set system will have only the Power indicator lit This is an armed system indication 4188 69...

Страница 2: ...arm all of the zones and become Set as the user leaves the property and closes the final door Program 2 To protect the perimeter of the property in the evening and become Set after say 20 seconds Pro...

Страница 3: ...r when you try to Set it the sounder will produce an open zone tone and the fault will be displayed Either re enter your code to turn off and investigate or omit the faulty zone s from the system How...

Страница 4: ...is Unset When a zone that is set to chime is operated the internal sounder will produce a low volume two stage warning tone and the Zone indicator will show The indicator may be cancelled by pressing...

Страница 5: ...ll starts with the newest event number 8 to the oldest one number 1 4188 693 issue 1 8 01 5 Citadel XR1 G3 intruder system Operating instructions Operator s Program mode Reset Quit the current functio...

Страница 6: ...ZONE 1 4 Rising beeps Attack Leave program mode Day Tamper Attack Acknowledge NOTE The sounder will produce a flat beep if code is rejected Enter Operator s program mode Example To create user 2 code...

Страница 7: ...m 4188 693 issue 1 8 01 7 Citadel XR1 G3 intruder system Operating instructions How to carry out Alarm and Walk tests Reset Reset Alarm test 0 Attack x1 for zone 1 x2 for zone 2 x4 for zone 4 flat x1...

Страница 8: ...m or Set a Program and while the system is setting ZONE S TO BE ARMED n Press the zone s to be omitted ZONE S TO BE OMITTED Exit beep Exit beep 10 seconds insistent beeps Day To exit Operator s progra...

Отзывы: