7. Infrared Configuration Unit (ICU) guide

Inserting and replacing batteries

The ICU uses 2 AAA or LR03 alkaline batteries, 
these must be installed before use. Always use 
new batteries of the same type. Install as indicated 
in the battery compartment on the rear of the ICU.

Activating cleaning mode

Cleaning mode, disables normal operation for 
cleaning for a timed 30 seconds. In order to 
activate cleaning mode with the ICU, it must be 
pointed at the sensor of the selected washroom 
product. Activation is most effective when the 

 

clean button is held down as the ICU is brought 
close to the sensor. It can take up to 3 seconds 
for the product to sense the ICU.

When the washroom product is in Clean Mode, 
the sensor flashes green once a second.

Activating ICU configuration 
mode

In order to activate ICU configuration mode with 
the ICU, it must be pointed at the sensor of the 
selected washroom product. Activation is most 
effective when the 

 configuration button is held 

down as the ICU is brought close to the sensor. It 
can take up to 3 seconds for the product to sense 
the ICU.

The washroom product will return to normal 
operation if there are no button presses for  
30 seconds.

Infrared taps

The ICU can adjust/activate the sensor 
range, the run-on time and the 12hr  
hygiene cycle settings.

The product must always be put into ICU 
configuration mode before any setting can 
be configured.

Activates cleaning mode

Activates ICU configuration mode

Decreases setting

Increases setting

Checks the setting being altered

Saves changes and exits ICU configuration mode

Quits ICU configuration mode without saving changes

Configures sensor range

Configures run-on time

12 hour hygiene cycle activation

Resets to default factory settings

1

4

5

NOTE:

 Not supplied but available from Cistermiser or any major plumbing merchant.

9

Button descriptions

NOTE:

 Batteries should be replaced when  

the signal of the ICU becomes weak and it  
becomes difficult to activate either cleaning or  
configuration mode.

Содержание Novatap

Страница 1: ...Infrared Taps Installation Guide a Cistermiser OUR WORLD IS WATER...

Страница 2: ...cycle to reduce the risk of legionella 1 2 3 4 5 9 10 11 x 4 7 8 x 4 x 2 x 2 6 12 A 13 14 1 2 3 4 5 8 9 10 x 4 7 x 2 11 12 13 14 LT versions include one power option one flow regulator Supplied parts...

Страница 3: ...tallation Do not install opposite a mirror Minimum 0 5 Bar dynamic pressure NOTE When installing the inlet pipework it is good plumbing practice to ensure that there is an accessible isolating valve u...

Страница 4: ...the tap Ensure the nozzle is not over tightened as this may pinch the O ring and cause the tap to leak NOTE Use extension cable where necessary Ensure correct polarity is maintained connect orange le...

Страница 5: ...both simultaneously 4 Usage advice and specification Minimum operating pressure 0 5 bar dynamic Maximum operating pressure 6 bar dynamic or static whichever is highest Factory settings Range 18cm Run...

Страница 6: ...6 www cistermiser co uk 5 Component dimensions Novatap 147mm 45mm 200mm 120mm 12...

Страница 7: ...at under 0 5 bar dynamic pressure Flow Rate litre min Supply pressure bar 8 7 2 3 4 6 5 4 3 2 5 1 0 1 Flow rate chart 0 5 litres per minute aerated blue 3 5 litres per minute non aerated blue Vectata...

Страница 8: ...ove your hand out of the line of sight of the sensor The water will cease and the run on time will be set C 4 After configuration the unit will flash amber giving opportunity to re enter configuration...

Страница 9: ...tion is most effective when the configuration button is held down as the ICU is brought close to the sensor It can take up to 3 seconds for the product to sense the ICU The washroom product will retur...

Страница 10: ...nfiguration code by pressing the button Exit without saving by pressing the button Configuring the 12hr hygiene rinse cycle Point the ICU at the sensor and press the 5 12hr hygiene rinse button the se...

Страница 11: ...ry powered Ensure power is switched on and is reaching the tap check all electrical connections Water is flowing when no user is present Water supply Ensure water pressure is not above maximum dynamic...

Страница 12: ...r for advice Red flash once every second Low battery power Change batteries Red flash twice every three seconds Sensor covered or heavily scratched Uncover sensor or polish out scratches Cistermiser p...

Страница 13: ...s or battery power or multi product power supply unit is connected 9 Check operation adjust sensor range and run on time adjustment see advanced settings guide Product serial number Installation addre...

Страница 14: ...f hygiene from the minimum volume of water WC flushing Easyflush Wave An infrared hands free and water conserving WC cistern flush valve suitable for concealed or exposed cisterns Easy to install in r...

Страница 15: ...nd eliminates the risk that the tap may be left running Vectatap An elegantly designed infrared tap with the benefit of hygienic hands free operation Vectatap improves water and energy efficiency and...

Страница 16: ...worldwide www keraflo co uk Homeboost is an intelligent pump from Salamander Pumps that recognises when water flow is less than 12 ltrs min and automatically boosts the performance of the incoming ma...

Отзывы: