7. Infrared Configuration Unit (ICU) guide
Inserting and replacing batteries
The ICU uses 2 AAA or LR03 alkaline batteries,
these must be installed before use. Always use
new batteries of the same type. Install as indicated
in the battery compartment on the rear of the ICU.
Activating cleaning mode
Cleaning mode, disables normal operation for
cleaning for a timed 30 seconds. In order to
activate cleaning mode with the ICU, it must be
pointed at the sensor of the selected washroom
product. Activation is most effective when the
clean button is held down as the ICU is brought
close to the sensor. It can take up to 3 seconds
for the product to sense the ICU.
When the washroom product is in Clean Mode,
the sensor flashes green once a second.
Activating ICU configuration
mode
In order to activate ICU configuration mode with
the ICU, it must be pointed at the sensor of the
selected washroom product. Activation is most
effective when the
configuration button is held
down as the ICU is brought close to the sensor. It
can take up to 3 seconds for the product to sense
the ICU.
The washroom product will return to normal
operation if there are no button presses for
30 seconds.
Infrared taps
The ICU can adjust/activate the sensor
range, the run-on time and the 12hr
hygiene cycle settings.
The product must always be put into ICU
configuration mode before any setting can
be configured.
Activates cleaning mode
Activates ICU configuration mode
Decreases setting
Increases setting
Checks the setting being altered
Saves changes and exits ICU configuration mode
Quits ICU configuration mode without saving changes
Configures sensor range
Configures run-on time
12 hour hygiene cycle activation
Resets to default factory settings
1
4
5
NOTE:
Not supplied but available from Cistermiser or any major plumbing merchant.
9
Button descriptions
NOTE:
Batteries should be replaced when
the signal of the ICU becomes weak and it
becomes difficult to activate either cleaning or
configuration mode.