Configuring sensor range
Point the ICU at the sensor and press the
1
sensor range button (the sensor blinks green).
Decrease or increase the sensor range by pressing
the
and
buttons respectively. The sensor blinks
red when the min or max value is reached.
Press the
button to check the sensor range
setting – the sensor displays the current setting by
flashing green, see table.
Save setting and exit ICU configuration mode by
pressing the
button.
Exit without saving by pressing the
button.
Configuring run-on time
Point the ICU at the sensor and press the
4
run-on time button (the sensor blinks green).
Decrease or increase the run-on time by pressing
the
and
buttons respectively. The sensor blinks
red when the min or max value is reached.
Press the
button to check the run-on time
setting – the sensor displays the current setting by
flashing green, see table.
Save setting and exit ICU configuration code by
pressing the
button.
Exit without saving by pressing the
button.
Configuring the 12hr hygiene
rinse cycle
Point the ICU at the sensor and press the
5
12hr hygiene rinse button (the sensor blinks green).
Decrease or increase the hygiene rinse time by
pressing the
and
buttons respectively. The
sensor blinks red when the min or max value is
reached.
Press the
button to check the hygiene rinse
time setting – the sensor displays the current
setting by flashing green, see table.
Save setting and exit ICU configuration mode by
pressing the
button.
Exit without saving by pressing the
button.
Reset to factory settings
Point the ICU at the sensor and press the
9
reset button (the sensor blinks green). This sets all
settings to the default factory settings.
Save setting and exit ICU configuration mode by
pressing the
button.
Exit without saving by pressing the
button.
Number of flashes
1
2
3
4
5
Range (cm approx)
8
11
14
16
18
Number of flashes
1
2
3
4
5
6
7
8
Run-on time (sec)
1
2
3
4
5 10 20 30
Number of flashes
1
2
3
4
5
6
Hygiene rinse time
(sec)
0
5
10 15 30 60