background image

10   | 

www.

cistermiser

.co.uk

Configuring sensor range

Point the ICU at the sensor and press the

 1

 

 

sensor range button (the sensor blinks green).

Decrease or increase the sensor range by pressing 
the

and

buttons respectively. The sensor blinks 

red when the min or max value is reached.

Press the 

 button to check the sensor range 

setting – the sensor displays the current setting by 
flashing green, see table.

Save setting and exit ICU configuration mode by 
pressing the

button.

Exit without saving by pressing the

button.

Configuring run-on time

Point the ICU at the sensor and press the 

4

 

 

run-on time button (the sensor blinks green).

Decrease or increase the run-on time by pressing 
the

and

buttons respectively. The sensor blinks 

red when the min or max value is reached.

Press the 

 button to check the run-on time 

setting – the sensor displays the current setting by 
flashing green, see table.

Save setting and exit ICU configuration code by 
pressing the

button.

Exit without saving by pressing the

button.

Configuring the 12hr hygiene  
rinse cycle

Point the ICU at the sensor and press the 

5

 

 

 

12hr hygiene rinse button (the sensor blinks green).

Decrease or increase the hygiene rinse time by 
pressing the

and

buttons respectively. The 

sensor blinks red when the min or max value is 
reached.

Press the 

 button to check the hygiene rinse 

time setting – the sensor displays the current 
setting by flashing green, see table.

Save setting and exit ICU configuration mode by 
pressing the

button.

Exit without saving by pressing the

button.

Reset to factory settings

Point the ICU at the sensor and press the 

9

 

 

reset button (the sensor blinks green). This sets all 
settings to the default factory settings.

Save setting and exit ICU configuration mode by 
pressing the

button.

Exit without saving by pressing the

button.

Number of flashes

1

2

3

4

5

Range (cm approx)

8

11

14

16

18

Number of flashes

1

2

3

4

5

6

7

8

Run-on time (sec)

1

2

3

4

5 10 20 30

Number of flashes

1

2

3

4

5

6

Hygiene rinse time 
(sec)

0

5

10 15 30 60

Содержание Novatap

Страница 1: ...Infrared Taps Installation Guide a Cistermiser OUR WORLD IS WATER...

Страница 2: ...cycle to reduce the risk of legionella 1 2 3 4 5 9 10 11 x 4 7 8 x 4 x 2 x 2 6 12 A 13 14 1 2 3 4 5 8 9 10 x 4 7 x 2 11 12 13 14 LT versions include one power option one flow regulator Supplied parts...

Страница 3: ...tallation Do not install opposite a mirror Minimum 0 5 Bar dynamic pressure NOTE When installing the inlet pipework it is good plumbing practice to ensure that there is an accessible isolating valve u...

Страница 4: ...the tap Ensure the nozzle is not over tightened as this may pinch the O ring and cause the tap to leak NOTE Use extension cable where necessary Ensure correct polarity is maintained connect orange le...

Страница 5: ...both simultaneously 4 Usage advice and specification Minimum operating pressure 0 5 bar dynamic Maximum operating pressure 6 bar dynamic or static whichever is highest Factory settings Range 18cm Run...

Страница 6: ...6 www cistermiser co uk 5 Component dimensions Novatap 147mm 45mm 200mm 120mm 12...

Страница 7: ...at under 0 5 bar dynamic pressure Flow Rate litre min Supply pressure bar 8 7 2 3 4 6 5 4 3 2 5 1 0 1 Flow rate chart 0 5 litres per minute aerated blue 3 5 litres per minute non aerated blue Vectata...

Страница 8: ...ove your hand out of the line of sight of the sensor The water will cease and the run on time will be set C 4 After configuration the unit will flash amber giving opportunity to re enter configuration...

Страница 9: ...tion is most effective when the configuration button is held down as the ICU is brought close to the sensor It can take up to 3 seconds for the product to sense the ICU The washroom product will retur...

Страница 10: ...nfiguration code by pressing the button Exit without saving by pressing the button Configuring the 12hr hygiene rinse cycle Point the ICU at the sensor and press the 5 12hr hygiene rinse button the se...

Страница 11: ...ry powered Ensure power is switched on and is reaching the tap check all electrical connections Water is flowing when no user is present Water supply Ensure water pressure is not above maximum dynamic...

Страница 12: ...r for advice Red flash once every second Low battery power Change batteries Red flash twice every three seconds Sensor covered or heavily scratched Uncover sensor or polish out scratches Cistermiser p...

Страница 13: ...s or battery power or multi product power supply unit is connected 9 Check operation adjust sensor range and run on time adjustment see advanced settings guide Product serial number Installation addre...

Страница 14: ...f hygiene from the minimum volume of water WC flushing Easyflush Wave An infrared hands free and water conserving WC cistern flush valve suitable for concealed or exposed cisterns Easy to install in r...

Страница 15: ...nd eliminates the risk that the tap may be left running Vectatap An elegantly designed infrared tap with the benefit of hygienic hands free operation Vectatap improves water and energy efficiency and...

Страница 16: ...worldwide www keraflo co uk Homeboost is an intelligent pump from Salamander Pumps that recognises when water flow is less than 12 ltrs min and automatically boosts the performance of the incoming ma...

Отзывы: