3. Power connections
If using the battery case, open it and fit 4 Alkaline AA (LR-6) batteries as indicated. Reseal and fasten into
place on panel using screws
A
or with the sticky pads.
If using the mains adapter, fasten into place on panel in a dry location using screws
A
or with the sticky
pads and connect the un-terminated mains cable to a 50Hz 230V AC single phase supply via a 1A fused
spur (not supplied).
Electrical connection
Connect the power connector from the tap to the mains adapter, or in the case of a battery powered
installation, the battery case.
NOTE:
Only one power source should be connected at any time, either mains or batteries. It is not possible
to connect both simultaneously.
4. Usage advice and specification
Minimum operating pressure:
0.5 bar (dynamic)
Maximum operating pressure:
6 bar (dynamic or static – whichever is highest)
Factory settings
Range:
~18cm
Run-on time:
2 sec
Power requirements:
Either 6VDC from 4 x alkaline AA (LR6) batteries or 6VDC
regulated from mains adapter. (1A fused spur required)
Battery life:
2 years in normal conditions with recommended batteries.
A single red flashing of the LED indicates that the batteries
are low and need to be replaced.
Cleaning:
Clean with non-abrasive cleaner and water only.
Lens care:
Infrared lens can be polished with a soft cloth.
Electronic specification
Control classification:
Independent
Maximum load:
Internal valve models: 1.2W 0.2A (6VDC)
External valve models: 2W 0.33A (6VDC)
EMC emissions:
Tested at above load
Rated temperature range:
0-40° C
Action classification:
Type 1.Y
Pollution classification:
Degree 1