NOTES:
Do not position sensor near toilet roll holder
or grab rail.
Reflective surfaces and materials such as
hi-vis jackets may cause the sensor to
activate unexpectedly.
Walkaway version only.
Minimum distance
applies. If x (see diagram) is less than 12cm it
is recommended that the Hand Activation is
disabled. Refer to section 11.
4.
Easyflush
EVO
Valve Set up
Ensure the fill valve is adjusted so the water shuts off at the indicated water level on the flush valve. This is
your full flush volume.
The height of the
Easyflush
EVO
flush valve water level and the filling valve float level
must
be at the
same height.
To adjust
Easyflush
EVO
Fill Valve rotate
the adjuster at top of valve
Easyflush
EVO
Flush
Valve water level
Unlock
To adjust height of
Easyflush
EVO
Flushing Valve rotate upper body
clockwise to release.
Adjust
Lift or lower upper body to adjust
height.
Lock
Rotate anticlockwise to lock.
5. Sensor Positioning
Easyflush
EVO
can be operated by Wave activation (default) or Walkaway activation. The installed position of
the sensor will depend on your flush activation setting (see below).
Wave activation is the default setting and the WC will flush when the user’s hand is placed in front of the sensor.
Alternatively, with the Walkaway activation setting, the WC will automatically flush when the user leaves the cubicle.
See Config in section 12 to change the sensor activation from Wave to Walkaway.
Top
WC
Front
Side
WC
WC
300 – 400mm
700
– 900mm
Exposed installation
Cistern mounted sensor
(Wave activation only, default)
Concealed installation
Panel mounted sensor
(Wave activation only, default)
Concealed installation
Panel mounted sensor
(Walkaway activation only)
x
Drill hole to the required
diameter (refer to page 8).