Commissioning check-list
Easyflush
EVO
Product serial number
Installation address
No Activity
1.
Ensure the cistern is installed level (check with spirit level).
2.
Ensure the Flush Valve height is set to give the correct flush volume. Ensure the
Fill Valve float height is adjusted so the water line is level with the indicator on the
Flush Valve.
3.
Ensure water supply is activated. For EVO CISTERN 0.1 - 10 bar.
4.
Check sensor is mounted in correct position (refer to section 5).
6.
Ensure label is removed from sensor before connecting power.
7.
Check power connections (refer to section 6).
8.
Ensure either mains or battery power or multi product power supply is connected.
9.
Check sensor range, refill time, full flush times are suitable for installation (refer to
advanced settings guide section 11).
10.
Test operation.
a
Wave: Place hand within ~10cm of sensor for 1 second = valve will part flush and
the sensor will flash the single green LED once per second. Place hand within
10cm of sensor for two seconds = valve will full flush and the sensor will flash the
double bottom green LEDs once per second.
b
Walkaway: If presence is detected, sensor flashes green once every three seconds.
When sensor detects a presence for less than 45 seconds, valve will part flush.
Where sensor detects a presence for over 45 seconds valve will full flush.
Checked Date
The warranty on Cistermiser products can be extended within one year of date
of manufacture, at no cost, to three years from the date of installation. Once
the valve has been installed, complete the product commissioning checklist
below to demonstrate compliance with the installation instructions. Email a
photograph of this completed form to
or post to
Cistermiser, Unit 1, Woodley Park Estate, 59-69 Reading Road, Woodley,
Berks, RG5 3AN.
3
YEAR
warranty
extended
Notes