Page 24
S6162-BS-MMC-010/12489
Troubleshooting Chart
T R O U B L E
C A U S E
R E M E D Y
Replace
V-Belt.
Adjust
belt
tension.
Tighten
set
screw.
Replace timer
Replace
thermostat.
Check
timer
to
see
if
operating.
Adjust
timer
(See
Furnas
control
sheet).
Check manual for proper leveling procedures.
Accidental damage to the fan blade can change
the dynamic balance. Damaged fans should be
replaced.
Adjust
basket
clearance.
Tighten set screws, make sure sheaves are in
proper alignment.
Adjust
belt
tension.
Occasionally
screws,
nails,
etc.
will
hand
in
the
basket perforations and drag against the sweep
sheets surrounding the basket. Such foreign
objects should be removed immediately.
Replace
contactor.
Replace motor.
Replace
timer.
V-Belt
broken.
V-Belt
loose.
Motor
pulley
loose.
Defective
timer.
Defective Therm-
O-Cool
thermostat.
Reversing
timer.
Reversing
timer.
Not
leveled.
Fan out of balance.
Basket rubbing.
V-Belt
sheaves.
Belt.
Foreign
objects.
Defective
blower
contactor.
Defective
motor.
Defective
timer.
Basket motor runs, but
basket
will
not
revolve.
Dryer does not stop at
end
of
cycle.
Basket does not reverse.
Dryer noisy or
vibrating.
Blower motor will not
run
(Basket
Revolves).
Dryer does not stop at
end
of
time
period.
Содержание L36TD30ME
Страница 10: ...Page 10 S6162 BS MMC 010 12489...
Страница 20: ...Page 20 S6162 BS MMC 010 12489 RECOMMENDED STEAM PIPING INSTALLATION ILLUSTRATION...
Страница 40: ...Page 40 S6162 BS MMC 010 12489 BACK CHANNEL BOLTED ASSEMBLY TU10600...
Страница 50: ...Page 50 S6162 BS MMC 010 12489...
Страница 51: ...Page 51 S6162 BS MMC 010 12489...
Страница 52: ...Page 52 S6162 BS MMC 010 12489...
Страница 53: ...Page 53 S6162 BS MMC 010 12489...