Page 21
S6162-BS-MMC-010/12489
O P E R A T I N G I N S T R U C T I O N S
Step
1.
After
loading
the
dryer
tumbler
with
the
washed
clothes
load,
proceed
to
close
the
loading
door.
Step
2.
Timer
Models
-
Turn
drying
timer
knob
to
the
desired
drying
time.
Step
3.
Temperature
Selector
-
Select
temperature
per
type
of
load
being
dried
in
the
dryer.
High
Heat
-
mixed
and
heavy
fabrics
-
180°
F
exhaust
temperature.
Low
Heat
-
poly
knit
synthetic-blends-light
weight
fabrics
-
160°
F
exhaust
temperature.
Step
4.
Turn
ON/OFF
switch
to
“ON”
position.
Step
5.
Push
the
Push-to-Start
button.
The
“Drying”
light
will
be
“On”.
Note: After the dryer has worked for your “set” amount of time, the machine
will
go
into
the
automatic
cool-down
setting
(the
“Cool-Down”
light
will
be
“On”). The machine will operate automatically until the exhaust
temperature reaches 135° F.
At this point the machine will stop and a “buzzer” will be turned “On”.
Step
6.
Turn “ON/OFF” switch to “OFF”. At this point, the buzzer will stop.
G E N E R A L M A I N T E N A N C E
1. CLEAN LINT TRAP DAILY: Remove lint daily before starting operation.
A
clean
lint
trap
will
increase
the
efficiency
of
the
dryer,
as
the
moisture
laden air will be exhausted to the atmosphere more quickly.
2. KEEP BASKET AND SWEEP SHEETS CLEAN: Check periodically and
clean as often as required. The basket and sweep sheets within the dryer
are
easily
accessible
for
cleaning
by
removing
the
front
panel
of
the
dryer.
Take
screws
out
of
front
panel,
then
lift
panel
off.
3. PULLEYS (SHEAVE) AND BELT: Keep belts clean. Oil and dirt will
shorten
the
useful
life
of
a
belt.
Never
allow
a
belt
to
run
against
the
belt
guard.
Check
belts
periodically for
alignment.
Pulley
shafts
must
be
parallel and the grooves must be in alignment. To align pulley, loosen set
screw and slide pulley in or out to align up with the other pulley. Tighten
set
screw
securely.
4. ELECTRIC MOTORS: Keep motors clean and dry. Occasionally blow
dust out of winding. After 3 years normal or 1 year heavy duty service all
oil.
No
reoiling
normally
required
for
light
duty
with
total
operating
time
under 25,000 hours. Use electrical motor or S.A.E. 10 oil. DO NOT
OVER OIL.
5. GEAR REDUCER: Maintain oil level in gear reducer 1/2 depth of oil cup.
Transmission
oil
to
meet
military
specification
MIL-L-6086B.
Содержание L36TD30ME
Страница 10: ...Page 10 S6162 BS MMC 010 12489...
Страница 20: ...Page 20 S6162 BS MMC 010 12489 RECOMMENDED STEAM PIPING INSTALLATION ILLUSTRATION...
Страница 40: ...Page 40 S6162 BS MMC 010 12489 BACK CHANNEL BOLTED ASSEMBLY TU10600...
Страница 50: ...Page 50 S6162 BS MMC 010 12489...
Страница 51: ...Page 51 S6162 BS MMC 010 12489...
Страница 52: ...Page 52 S6162 BS MMC 010 12489...
Страница 53: ...Page 53 S6162 BS MMC 010 12489...