background image

The installation, including a proper exhaust system, is the responsibility of the owner.

LEAVE THESE INSTRUCTIONS WITH THE OWNER

Printed in U.S.A.

6 2721750

STACKED WASHER / DRYER

INSTALLATION INSTRUCTIONS

For further information, call 1-888-4-MAYTAG (1-888-462-9824).

FACTORY STACKED VERSION

Содержание Stacked Washer/Dryer

Страница 1: ...ust system is the responsibility of the owner LEAVE THESE INSTRUCTIONS WITH THE OWNER Printed in U S A 6 2721750 STACKED WASHER DRYER INSTALLATION INSTRUCTIONS For further information call 1 888 4 MAYTAG 1 888 462 9824 FACTORY STACKED VERSION ...

Страница 2: ...cm Location of Canadian terminal block gas models Location of washer water valve connections 3 8 min 95 cm Exit location of washer drain hose 271 2 69 9 cm Dryer Washer 5 8 1 6 cm 3 4 1 9 cm 11 8 2 9 cm 271 2 69 9 cm Make sure you have everything necessary for proper installation 1 GROUNDED ELECTRICAL OUTLET is required See Electrical Requirements starting on page 6 2 POWER CORDS for electric drye...

Страница 3: ...air There must be a minimum of 36 square inches of unobstructed space surrounding the dryer For a gas dryer adequate clearance as noted on the data plate must be maintained to insure adequate air for combustion and proper operation of the dryer THE DRYER MUST NOT BE INSTALLED OR STORED IN AN AREA WHERE IT WILL BE EXPOSED TO WATER AND OR WEATHER THE DRYER AREA IS TO BE KEPT CLEAR AND FREE FROM COMB...

Страница 4: ...t under a house or porch If exhaust ductwork must run through an unheated area the duct should be insulated and slope slightly down towards the exhaust hood to reduce condensation and lint build up If an existing exhaust system is to be used with your dryer s you must be sure The exhaust system meets all local state and national codes That plastic flexible duct is not used To completely inspect an...

Страница 5: ...proper height The drain hose is attached at the factory Maximum flow rate is 12 gallons per minute FLOORING For best performance the washer must be installed on a solidly constructed floor Wood floors may need to be reinforced to minimize vibration and or unbalanced load situations Carpeting and soft tile surfaces are contributing factors in vibration and or tendency for a washer to move slightly ...

Страница 6: ...o the dryer The dryer must be disconnected from the gas supply piping system during any pressure testing of the system DO NOT re use old flexible metal gas line Flexible gas line must be design certified by American Gas Association CGA in Canada NOTE Any pipe joint compound used must be resistant to the action of any liquefied petroleum gas NOTE As a courtesy most local gas utilities will inspect ...

Страница 7: ...ection above An individual branch or separate circuit serving only this appliance is recommended DO NOT USE AN EXTENSION CORD GAS MODELS U S and Canada A 120 volt 60 Hz AC approved electrical supply with a 15 ampere fuse or circuit breaker is required WARNING Improper connection of the equipment grounding conductor can result in a risk of electric shock Check with a qualified electrician or servic...

Страница 8: ...attached It is not permissible to convert a dryer in Canada to 208 volts Additional Instructions for Export Models not U S or Canada Contact the distributor that sold the appliance or Maytag International 8700 W Bryn Mawr Avenue Chicago Illinois USA 60631 773 714 0100 for information on product shipping damage replacement parts and accessories Maytag models manufactured for operation on 60 Hz AC a...

Страница 9: ... Service 240 Edwards Street S E Cleveland Tennessee 37311 Phone 1 888 4 MAYTAG 1 888 462 9824 for information on the nearest authorized Maytag Parts Distribu tor EXPORT MODELS Contact the Commercial Distributor from whom you purchased your appliance or Maytag International 8700 W Bryn Mawr Avenue Chicago Illinois USA 60631 Phone 773 714 0100 for information on the nearest authorized Maytag Parts D...

Страница 10: ... two corner posts behind the appliance and gently tip the appliance over on to its back See figure 3 3 Pull loose straps from the bottom of the washer one at a time until all straps have been removed See figure 4 4 Remove the crate bottom from the appliance See figure 5 5 Loosen the four adjustable washer legs and lock nuts enough to fit a wrench on the lock nut See figure 6 Carefully raise the wa...

Страница 11: ...t be supported by the drain hose clip on the back of the washer Install one screen strainer and washer at the faucet end of each fill hose The dome on the screen strainer must point towards the faucet See figure 10 Attach the inlet hoses with the screen washer to the HOT and COLD faucets Tighten by hand until snug and then 2 3 of a turn with pliers Do not overtighten NOTE Accessory inlet hoses are...

Страница 12: ...NOT use excessive force in tightening threads as this may damage internal components Check all gas supply connections from service valve for leaks using a soap solution DO NOT use an open flame to check for gas leaks If bubbles occur tighten the connections and recheck NOTE As a courtesy many local gas utilities will inspect a gas appliance installation Check with your local utility to see if this...

Страница 13: ...hers ahead of the nuts Be sure the terminal block nuts are tight but do not overtighten Secure the power cord in position Tighten the strain relief screw s in order to clamp the strain relief to the cord See figure 13 Replace the terminal block cover BEFORE OPERATING OR TESTING follow the grounding directions on page 5 4 WIRE SYSTEM CONNECTIONS Remove the ground strap screw from the terminal block...

Страница 14: ...e tight Secure the power cord in position Tighten the strain relief screw s in order to clamp the strain relief to the cord Replace the terminal block cover BEFORE OPERATING OR TESTING be sure the machine is properly grounded EXPORT GAS MODELS Export gas models are manufactured for operation on either 230 240 volt 50 Hz or 220 volt 60 Hz AC approved electrical service with a 15 ampere fuse or circ...

Страница 15: ...ch hold hinges to door assembly 2 Set door aside and transfer four color matched door screws to the opposite side of the door assembly 3 Remove one screw holding top hinge to cabinet and one screw holding top hinge cover to cabinet opposite side 4 Remove hinge and bracket from cabinet by moving them up and down to a position where they are released 5 Install hinge and bracket in swapped locations ...

Страница 16: ...t for proper operation by running the washer through a complete cycle 1 Select Cotton Sturdy Hot Cold and Max Extract Make sure the Extra Rinse option is not selected 2 Turn the timer dial to Heavy Normal Light wash and press the Start Stop button 3 Verify the washer is filling from the hot water valve 4 Verify the washer stops filling 5 Push Start Stop to stop washer 6 Turn the timer dial to Fina...

Страница 17: ...0 16cm hole 059134 Clamp for 4 duct 304630 Exhaust duct kit for base or left side exhausting 12001453 Rectangular vent kits 059144 Back draft damper 4 059146 NATURAL to LP conversion kit 306195 LP to NATURAL conversion kit 306204 Anchor bracket kit 303740 Heating element conversion kit 208 v 308590 NOT FOR CANADA Grounding Kit 12001875 Power cords 240 v 30 A 10 3 wire 33001838 10 4 wire 33002441 ...