background image

Page 14

CONTROL PANEL & ACCESS DOOR ASSEMBLY

50/75 

Lb. 

Dryers 

 Reversing/Non-Reversing

Ref. No.

Part No.

Description

1

TU3400

#6-32 Brass Nut

2

TU12254

Spacer

3

TU12105

Reversing Control Board

TU12106

Non-Rev. Control Board

4

TU12195

Reversing Panel Label

TU12196

Non-Rev. Panel Label

5

TU12835

Control Panel

6

TU12834

Access Door

7

TU7983

Trim

8

TU8013

Cissell 

Label

9

TU3479

#10-32 Truss Hd. Screw

10

P104

1/4” Cut Washer

11

FB187

#10 Lockwasher

12

TU2842

#10-32 Hex Nut

13

TU4822

Lock

14

TU2844

Key JWC2

15

TU1771

Twin 

Clip 

Nut

16

TU9524

#6 

5/16” 

Screw

17

TU5739

Support 

Rod

18

TU12863

Fuse 

Amp.

19

ET235

Fuse 

3/8 

Amp.

Содержание ACDCMAN407

Страница 1: ...NTAL OWNER S MANUAL THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER CISSELL MANUFACTURING COMPANY H E A D Q U A R T E R S PHONE 502 587 1292 831 SOUTH FIRST ST SALES FAX 502 585 3625 P O BOX 32270 SE...

Страница 2: ...the clothes and signals the control when they are dry In the timed mode the operator sets the time and temperature for the load FEATURES Automatic Timed drying selection Automatic Timed cooling select...

Страница 3: ...grees F will be shown in the display To change the temperature use the up and down buttons The drying temperature cannot be changed when Automatic Drying is selected the temperature associated with th...

Страница 4: ...Page 4 CONTROL PANEL ILLUSTRATION...

Страница 5: ...1 5 END OF CYCLE Illuminated at the end of the cycle 1 6 OPEN DOOR Illuminated when the door is open START must be pressed to restartthecycleafterclosingthedoor DISPLAY Display Condition __0 Normal di...

Страница 6: ...d on this switch setting The parameters that are stored will be used by the control when the REPEAT LAST CYCLE button is pressed prior to starting a drying c y c l e 4 2 DEG Adds 2 Degrees to the diff...

Страница 7: ...Page 7 CONTROL BOARD AND OPTIONS ILLUSTRATION...

Страница 8: ...board Reversing Dwell Time This potentiometer is used to set the dwell time when the dryer has the reversing option The dwell is the time from when the motor turns off to when it turns on again in th...

Страница 9: ...ill stop To restart the cycle close the door and press START When the door is closed the display will flash the current cycle time until the START button is pressed AUTO TIMED Indicates the selection...

Страница 10: ...In TIMED mode pressing and holding this button will show in the display the current time in minutes set for the cooling cycle In the TIMED mode only the cooling time can be changed by pressing and hol...

Страница 11: ...he control will automatically turn itself off Push ON to power up the control Dryness Sensor When in the AUTO drying mode the length of the cycle is controlled by a dryness sensor The sensor works on...

Страница 12: ...d Bolt 5 TU2846 Washer 6 P104 1 4 Cut Washer 7 FB187 10 Lockwasher 8 TU2842 10 32 Hex Nut 9 TU9693 SnapBushing 2 1 2 10 TU3400 6 32 Hex Nut 11 TU12254 Spacer 12 TU3479 10 32 Truss Head Screw 13 TU1284...

Страница 13: ...oard 4 TU12195 ReversingPanelLabel TU12196 Non Rev Panel Label 5 TU12842 ControlPanel 6 TU12841 Access Door 7 TU11568 Trim 8 TU8013 CissellLabel 9 TU3479 10 32 Truss Hd Screw 10 P104 1 4 Cut Washer 11...

Страница 14: ...Control Board 4 TU12195 ReversingPanelLabel TU12196 Non Rev Panel Label 5 TU12835 ControlPanel 6 TU12834 Access Door 7 TU7983 Trim 8 TU8013 CissellLabel 9 TU3479 10 32 Truss Hd Screw 10 P104 1 4 Cut W...

Отзывы: