Cissell ACDCMAN407 Скачать руководство пользователя страница 5

Page 5

DESCRIPTION OF CONTROL PANEL (cont’d)

12.

LED Display.  Shows cycle time.  In Automatic, it shows the time used.  In

Timed, it shows the time remaining.  When the DRYING TEMPERATURE button

is pressed and held, the drying temperature will be displayed.  When the DRYING

TIME button is pressed and held, either the total drying time or “-A-” will be

displayed depending on whether AUTO or TIMED drying has been selected.

When the COOLING TIME button is pressed and held, either the total cooling

time or “-A-” will be displayed depending on whether AUTO or TIMED cooling has

been selected.

13.

DRYING.  Illuminated when in the drying cycle.

14.

COOLING.  Illuminated when in the cooling cycle.

15.

END OF CYCLE.  Illuminated at the end of the cycle.

16.

OPEN DOOR.  Illuminated when the door is open.  (START must be pressed to

restart the cycle after closing the door.)

D I S P L A Y

Display

Condition

“__0”

Normal display between loads.  Dryer is waiting for the next

load.

“012”

Normal display during drying/cooling cycle.  Display shows

“time used” when in automatic and “time remaining” when in

timed mode.

“012” (flashing)

The door has been opened.  Close the door and press START

to continue the cycle.

“-S-” (flashing)

The dryer is in the Safety Tumble mode.  The cycle has ended

and the dryer can be unloaded.

“_PF” (flashing)

There has been a power failure.  To restart the dryer, press

ON and START.  To terminate the cycle press OFF/STOP.

“FFF” (flashing)

The temperature sensor has failed.  The dryer cannot be run

until it is repaired.

“-A-”

Indicates the automatic mode has been selected.  (DRYING

TIME and COOLING TIME only).

Содержание ACDCMAN407

Страница 1: ...NTAL OWNER S MANUAL THIS MANUAL MUST BE GIVEN TO THE EQUIPMENT OWNER CISSELL MANUFACTURING COMPANY H E A D Q U A R T E R S PHONE 502 587 1292 831 SOUTH FIRST ST SALES FAX 502 585 3625 P O BOX 32270 SE...

Страница 2: ...the clothes and signals the control when they are dry In the timed mode the operator sets the time and temperature for the load FEATURES Automatic Timed drying selection Automatic Timed cooling select...

Страница 3: ...grees F will be shown in the display To change the temperature use the up and down buttons The drying temperature cannot be changed when Automatic Drying is selected the temperature associated with th...

Страница 4: ...Page 4 CONTROL PANEL ILLUSTRATION...

Страница 5: ...1 5 END OF CYCLE Illuminated at the end of the cycle 1 6 OPEN DOOR Illuminated when the door is open START must be pressed to restartthecycleafterclosingthedoor DISPLAY Display Condition __0 Normal di...

Страница 6: ...d on this switch setting The parameters that are stored will be used by the control when the REPEAT LAST CYCLE button is pressed prior to starting a drying c y c l e 4 2 DEG Adds 2 Degrees to the diff...

Страница 7: ...Page 7 CONTROL BOARD AND OPTIONS ILLUSTRATION...

Страница 8: ...board Reversing Dwell Time This potentiometer is used to set the dwell time when the dryer has the reversing option The dwell is the time from when the motor turns off to when it turns on again in th...

Страница 9: ...ill stop To restart the cycle close the door and press START When the door is closed the display will flash the current cycle time until the START button is pressed AUTO TIMED Indicates the selection...

Страница 10: ...In TIMED mode pressing and holding this button will show in the display the current time in minutes set for the cooling cycle In the TIMED mode only the cooling time can be changed by pressing and hol...

Страница 11: ...he control will automatically turn itself off Push ON to power up the control Dryness Sensor When in the AUTO drying mode the length of the cycle is controlled by a dryness sensor The sensor works on...

Страница 12: ...d Bolt 5 TU2846 Washer 6 P104 1 4 Cut Washer 7 FB187 10 Lockwasher 8 TU2842 10 32 Hex Nut 9 TU9693 SnapBushing 2 1 2 10 TU3400 6 32 Hex Nut 11 TU12254 Spacer 12 TU3479 10 32 Truss Head Screw 13 TU1284...

Страница 13: ...oard 4 TU12195 ReversingPanelLabel TU12196 Non Rev Panel Label 5 TU12842 ControlPanel 6 TU12841 Access Door 7 TU11568 Trim 8 TU8013 CissellLabel 9 TU3479 10 32 Truss Hd Screw 10 P104 1 4 Cut Washer 11...

Страница 14: ...Control Board 4 TU12195 ReversingPanelLabel TU12196 Non Rev Panel Label 5 TU12835 ControlPanel 6 TU12834 Access Door 7 TU7983 Trim 8 TU8013 CissellLabel 9 TU3479 10 32 Truss Hd Screw 10 P104 1 4 Cut W...

Отзывы: