Cisco UCS B440 High Performance Blade Server Installation and Service Note
OL-22475-01
topicWorking Inside the Blade Server
c.
Remove the top cover as described in the
“Removing a Blade Server Cover” section on page 16
.
d.
Press the battery socket retaining clip toward the chassis wall (see
Figure 8
).
e.
Lift the battery from the socket. Use needle-nose pliers to grasp the battery if there is not enough
clearance for your fingers.
Step 2
Install a motherboard CMOS battery:
a.
Press the battery socket retaining clip toward the chassis wall.
b.
Insert the new battery into the socket with the battery’s positive (+) marking toward the chassis wall.
Ensure that the retaining clip clicks over the top of the battery.
c.
Replace the top cover.
d.
Replace the server in the chassis, and then power on the server by pressing the
Power
button.
Figure 8
Removing and Replacing a Motherboard CMOS Battery