b) On the
Advanced
tab, select
Trusted Computing
and press
Enter
to open the TPM Security Device
Configuration window.
c) Set the TPM State option to
Enabled
.
d) Press
F10
to save and exit. Allow the server to reboot, but watch for the prompt to press F2 in the next
step.
Step 4
Verify that TPM Support and TPM State are enabled.
a) Press
F2
during reboot to enter the BIOS setup screens.
b) On the
Advanced
tab, select
Trusted Computing
and press
Enter
to open the TPM Security Device
Configuration window.
c) Verify that TPM Support and TPM State are set to
Enabled
.
d) Continue with enabling the Intel TXT feature in the next step.
Step 5
Enable the Intel TXT feature in the BIOS.
a) Choose the
Advanced
tab.
b) Choose
Intel TXT (LT-SX) Configuration
to open the Intel TXT (LT-SX) Hardware Support window.
c) Set TXT Support to
Enabled
.
d) Verify that the following items are listed as Enabled:
• VT Support (default is Enabled)
• VT-d Support (default is Enabled)
• TPM Support
• TPM State
If VT Support and VT-d Support are not enabled, return to the
Advanced
tab, select
Processor
Configuration
, and then set Intel (R) VT and Intel (R) VT-d to
Enabled
.
e) Press
F10
to save and exit.
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v3 and E7 v2 CPUs
36
Servicing the Blade Server
Installing and Enabling a Trusted Platform Module