Figure 5: Removing a Slot Divider
To reinstall the slot divider, align it with the dimples in the slot top and bottom and slide it back
in until it clicks into place.
Tip
Step 2
Grasp the front of the blade module and place your other hand under the blade to support it.
Figure 6: Positioning a UCS B260 M4 Blade Module in the Chassis
Step 3
Open the ejector levers in the front of the blade module.
Step 4
Gently slide the blade into the blade slot opening until you cannot push it any farther.
Step 5
Press the ejector levers so that they latch with the edge of the chassis and press the blade module all the way
in.
Step 6
Tighten the captive screw on the front of the blade to no more than 3 in-lbs. Tightening with bare fingers will
prevent stripped or damaged captive screws.
Step 7
Attach the UCS Scalability Terminator or UCS Scalability Connector to the blade module(s) as follows:
Cisco UCS B260 M4 and B460 M4 Blade Server Installation and Service Note for Servers with E7 v3 and E7 v2 CPUs
10
Installing a Blade Server
Installing a Blade Server in the Chassis