S e n d d o c u m e n t c o m m e n t s t o u c s - d o c f e e d b a c k @ c i s c o . c o m
A-4
Cisco UCS 6100 Series Fabric Interconnect Hardware Installation Guide
OL-20036-02
Appendix A Technical Specifications
Transceiver Specifications
Environmental Conditions and Power Requirements Specification for SFP
Transceivers
Table A-7
provides the maximum environmental and electrical ratings for Cisco Fibre Channel SFP
transceivers.
Table A-7
Environmental Conditions and Power Requirements Specifications for SFP
Transceivers
Parameter
Symbol
Minimum
Maximum
Storage temperature
1
1.
Absolute maximum ratings are those values beyond which damage to the device may occur if these limits
are exceeded for other than a short period of time.
T
S
-40°C (-40°F)
85°C (185°F)
Case temperature
1,
2
2.
Functional performance is not intended, device reliability is not implied, and damage to the device may
occur over an extended period of time between absolute maximum ratings and the recommended
operating conditions.
T
C
0°C (32°F)
70°C (158°F)
Relative humidity
1
RH
5 %
95 %
Module supply voltage
1
V
CC
T,R
3.1 V
3.5 V