1-30
Cisco SFS 7012 InfiniBand Server Switch Hardware Users Guide
OL-8787-05
–
The module can no longer function properly. The system will take the appropriate actions to
ensure that no damage is done to its components.
•
Blinking
Amber
(once every four seconds) - LED test state.
Spine Module Management LEDs
Each SFS 7012 spine module has three management LEDs:
•
Capable:
–
Green
indicates that the spine slot supports management.
–
Off
indicates that the spine slot does not support management.
•
Stat:
–
Green
indicates that a management board is present.
–
Off
indicates that no management board is present.
•
Act:
–
Green
indicates that management board is in the active mode. In a redundantly-managed
system, this would indicate the master spine.
–
Off
indicates that the management board is in the standby mode (if the STAT LED is
Green
).
In a redundantly-managed system, if the Capable LED is also Green, this would indicate the
slave spine.
•
DDR:
–
Green
indicates that the switch is capable of running at DDR speeds.
–
Off
indicates that the switch is not capable of running at DDR speeds (i.e., SDR only).
Shutdown Procedures
In order to shutdown the SFS 7012:
Step 1
Power down the switch by removing the power cords from the AC power inlets.
Hot Swapping Components
Hot Swapping Spine and Leaf Modules
Note
Following are the general guidelines for hot swapping leaf and spine modules:
Caution
Be certain that the managed spine to be hot swapped is a that same firmware level as all other
components in the SFS 7012. A hot swap of a managed spine with another firmware level will cause a
disruptive reboot (i.e., I/O traffic is interrupted).