1-77
Cisco ONS 15454 DWDM Procedure Guide, Release 9.2
78-19286-01
Chapter 1 Install the Cisco ONS 15454 Shelf Assembly
Required Tools and Equipment (ETSI)
b.
For the TCC2P card:
•
All LEDs turn on briefly. The red FAIL LED, the yellow ACT/STBY LED, the green SYNC
LED, and the green ACO LED turn on for about 15 seconds.
•
The red FAIL LED and the green ACT/STBY LED turn on for about 30 seconds.
•
The red FAIL LED blinks for about 3 seconds.
•
The red FAIL LED turns on for about 15 seconds.
•
The red FAIL LED blinks for about 10 seconds and then becomes solid.
•
All LEDs (including the CRIT, MAJ, MIN, REM, SYNC, and ACO LEDs) blink once and turn
off for about 5 seconds.
•
Both green PWR LEDs turn on for 10 seconds. The PWR LEDs then turn red for 2 to 3 minutes
before going to steady green. During this time, the ACT/STBY, MJ, and MN LEDs might turn
on, followed by the SNYC LED briefly.
•
The boot-up process is complete when the PWR LEDs turn green and the yellow ACT/STBY
remains on. (The ACT/STBY LED will be green if this is the first TCC2P card installed, and
yellow if this is the second TCC2P card installed.)
Note
It might take up to three minutes for the A and B power alarms to clear.
Note
Alarm LEDs might be on; disregard alarm LEDs until you are logged into CTC and can view the
Alarms tab.
Note
If you are logged into CTC, the SFTWDOWN alarm might appear as many as two times while
the TCC2P card initializes. The alarm should clear after the card completely boots.
Note
If the FAIL LED is on continuously, see the tip in
about the TCC2P card automatic
upload.
c.
For the TCC3 card:
•
All LEDs turn on briefly. The red FAIL LED, the yellow ACT/STBY LED, the green SYNC
LED, and the green ACO LED turn on for about 25 seconds.
•
The red FAIL LED and the green ACT/STBY LED turn on for about 15 seconds.
•
The red FAIL LED blinks for about 3 seconds.
•
The red FAIL LED turns on for about 60 seconds.
•
The red FAIL LED blinks for about 15 seconds and then becomes solid (the LED is turned on
for about 20 seconds).
•
All LEDs (including the CRIT, MAJ, MIN, REM, SYNC, and ACO LEDs) blink once and turn
off for about 5 seconds.
•
Both green PWR LEDs turn on for 10 seconds. The PWR LEDs then turn red for 2 to 3 minutes
before going to steady green. During this time, the ACT/STBY, MJ, and MN LEDs might turn
on, followed by the SNYC LED briefly.
Содержание ONS 15454
Страница 48: ...Tables xlviii Cisco ONS 15454 DWDM Procedure Guide Release 9 2 78 19286 01 ...
Страница 58: ...Procedures lviii Cisco ONS 15454 DWDM Procedure Guide Release 9 2 78 19286 01 ...
Страница 78: ...Tasks lxxviii Cisco ONS 15454 DWDM Procedure Guide Release 9 2 78 19286 01 ...
Страница 85: ...lxxxv Cisco ONS 15454 DWDM Procedure Guide Release 9 2 78 19286 01 Preface ...
Страница 87: ...lxxxvii Cisco ONS 15454 DWDM Procedure Guide Release 9 2 78 19286 01 Preface ...