Cisco MDS 9200 Series Hardware 
Installation Guide

August 2009

Text Part Number: OL-19588-01

Содержание MDS 9200 Series

Страница 1: ...k d o c c i s c o c o m Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 Cisco MDS 9200 Series Hardware Installation Guide August 2009 Text Part Number OL 19588 01 ...

Страница 2: ...television or radio That is make certain the equipment and the television or radio are on circuits controlled by different circuit breakers or fuses Modifications to this product not authorized by Cisco Systems Inc could void the FCC approval and negate your authority to operate the product The Cisco implementation of TCP header compression is an adaptation of a program developed by the University...

Страница 3: ...vices Configuration Guides xvii Troubleshooting and Reference xviii C H A P T E R 1 Product Overview 1 1 Chassis 1 2 Integrated Supervisor Modules 1 5 Cisco MDS 9222i Integrated Supervisor Module 1 5 Cisco MDS 9216i Integrated Supervisor Module 1 6 Cisco MDS 9216A Integrated Supervisor Module 1 7 LEDs on the Cisco MDS 9200 Series Integrated Supervisor Modules 1 8 Interface Modules 1 9 LEDs on the ...

Страница 4: ...hannel Advanced Services Module 1 29 LEDs on the Fibre Channel Advanced Services Module 1 31 Caching Services Module 1 31 LEDs on the Caching Services Module 1 34 Power Supplies 1 35 Fan Module 1 36 Supported Transceivers 1 36 X2 Fibre Channel Transceivers 1 37 Fibre Channel SFP Transceivers 1 37 Combination Fibre Channel Gigabit Ethernet SFP Transceivers 1 37 CWDM Combination Fibre Channel Gigabi...

Страница 5: ...2 34 Maintaining a Caching Services Module 2 35 Maintaining the Batteries on the Caching Services Module 2 35 Maintaining the Disk Drives on the Caching Services Module 2 35 Removing and Installing Power Supplies 2 36 Removing a Power Supply 2 36 Installing a Power Supply 2 36 Removing and Installing the Fan Module 2 38 Removing a Fan Module 2 39 Installing a Fan Module 2 39 Removing the Cisco MDS...

Страница 6: ... 7 Installing the Switch on the Shelf Brackets A 8 Removing the Shelf Bracket Kit Optional A 9 A P P E N D I X B Technical Specifications B 1 Switch Specifications B 1 Module Specifications B 2 Weight of Modules B 3 Power Specifications B 4 Specifications for the Cisco MDS 9200 Series Power Supplies B 4 Component Power Requirements and Heat Dissipation Specifications B 5 X2 Transceiver Specificati...

Страница 7: ...16 Cisco CWDM SFP Transceivers B 17 Environmental and Optical Specifications for Cisco 2 Gbps CWDM SFP Transceivers B 18 Environmental and Optical Specifications for Cisco 4 Gbps CWDM SFP Transceivers B 19 Cisco Gigabit Ethernet Transceivers B 21 General Specifications for Cisco Gigabit Ethernet Transceivers B 21 Environmental and Power Requirement Specifications for Cisco Gigabit Ethernet Transce...

Страница 8: ...n t a t i o n c o m m e n t s t o m d s f e e d b a ck d o c c i s c o c o m Contents viii Cisco MDS 9200 Series Hardware Installation Guide OL 19588 01 Contact and Site Information D 3 Chassis and Module Information D 4 ...

Страница 9: ...tion Changed in Release Where Documented Cisco MDS 16 Port Storage Services Node SSN 16 Added Cisco MDS 16 Port Storage Services Node SSN 16 The SSN 16 module has 16 1 Gigabit Ethernet ports 4 2 1 Product Overview chapter Cisco MDS 16 Port Storage Services Node SSN 16 technical specifications Added Cisco MDS 16 Port Storage Services Node SSN 16 technical specifications 4 2 1 Technical Specificatio...

Страница 10: ...ge B 1 18 4 port Multiservice MSM 18 4 module Added the new 18 4 port Multiprotocol Services module 3 2 1 The 18 4 Port MultiserviceModule section on page 1 22 and the Technical Specifications section on page B 1 48 port 4 Gbps Fibre Channel switching module Added 48 port 4 Gbps Fibre Channel switching module The switching module offers 48 autosensing 1 2 and 4 Gbps Fibre Channel ports and can be ...

Страница 11: ...ransceiver The X2 transceiver is a small form factor pluggable optimized for 10 Gbps applications 3 0 1 The X2 Fibre Channel Transceivers section on page 1 37 and the X2 Transceiver Specifications section on page B 7 Fibre Channel SFP transceiver Added 4 Gbps Fibre Channel SFP trans ceiver 3 0 1 The Fibre Channel SFP Transceivers section on page 1 37 and the Cisco Fibre Channel SFP and SFP Transce...

Страница 12: ...Se n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck d o c c i s c o c o m xii Cisco MDS 9200 Series Hardware Installation Guide OL 19588 01 New and Changed Information ...

Страница 13: ...he Cisco MDS 9200 Series and its components Chapter 2 Installing the Cisco MDS 9200 Series Describes how to install the Cisco MDS 9200 Series and how to install modules power supplies and fan assemblies Chapter 3 Connecting the Cisco MDS 9200 Series Describes how to connect the Cisco MDS 9200 Series including the modules Appendix A Cabinet and Rack Installation Provides guidelines for selecting an...

Страница 14: ...kan veroorzaken Voordat u aan enige apparatuur gaat werken dient u zich bewust te zijn van de bij elektrische schakelingen betrokken risico s en dient u op de hoogte te zijn van standaard maatregelen om ongelukken te voorkomen Voor vertalingen van de waarschuwingen die in deze publicatie verschijnen kunt u het document Regulatory Compliance and Safety Information Informatie over naleving van veili...

Страница 15: ...l se oversettelser av de advarslene som finnes i denne publikasjonen kan du se i dokumentet Regulatory Compliance and Safety Information Overholdelse av forskrifter og sikkerhetsinformasjon som ble levert med denne enheten Aviso Este símbolo de aviso indica perigo Encontra se numa situação que lhe poderá causar danos físicos Antes de começar a trabalhar com qualquer equipamento familiarize se com ...

Страница 16: ...Information for the Cisco MDS 9000 Family Compatibility Information Cisco Data Center Interoperability Support Matrix Cisco MDS 9000 NX OS Hardware and Software Compatibility Information and Feature Lists Cisco MDS NX OS Release Compatibility Matrix for Storage Service Interface Images Cisco MDS 9000 Family Switch to Switch Interoperability Configuration Guide Cisco MDS NX OS Release Compatibility...

Страница 17: ...ng Configuration Guide Cisco Fabric Manager Cisco Fabric Manager Fundamentals Configuration Guide Cisco Fabric Manager System Management Configuration Guide Cisco Fabric Manager Interfaces Configuration Guide Cisco Fabric Manager Fabric Configuration Guide Cisco Fabric Manager Quality of Service Configuration Guide Cisco Fabric Manager Security Configuration Guide Cisco Fabric Manager IP Services ...

Страница 18: ...MDS 9000 Family Secure Erase Configuration Guide Cisco MDS 9000 Family Cookbook for Cisco MDS SAN OS Troubleshooting and Reference Cisco NX OS System Messages Reference Cisco MDS 9000 Family NX OS Troubleshooting Guide Cisco MDS 9000 Family NX OS MIB Quick Reference Cisco MDS 9000 Family NX OS SMI S Programming Reference Cisco MDS 9000 Family Fabric Manager Server Database Schema ...

Страница 19: ...s Switch module port interfaces that support field replaceable hot swappable small form factor pluggable SFP and enhanced small form factor pluggable SFP transceivers Nondisruptive code load and activation Redundant and self monitoring system clocks The Cisco MDS 9222i Multiservice Modular Switch provides an 18 port Fibre Channel switching and 4 port Gigabit Ethernet IP services module and a modul...

Страница 20: ...annel switching module DS X9032 16 port 2 Gbps Fibre Channel switching module DS X9016 18 4 port Multiservice MSM 18 4 module DS X9304 18K9 14 2 port Multiprotocol Services MPS 14 2 module DS X9302 14K9 8 port IP Storage Services IPS 8 module DS X9308 SMIP 4 port IP Storage Services IPS 4 module DS X9304 SMIP Storage Services Module SSM DS X9032 SSM Advanced Services Module ASM DS X9032 SMV Cachin...

Страница 21: ...switching module See the Cisco MDS 9216i Integrated Supervisor Module section on page 1 6 The Cisco MDS 9216A see Figure 1 3 has a nonremovable supervisor module in slot 1 with an integrated 16 port Fibre Channel switching module See the Cisco MDS 9216A Integrated Supervisor Module section on page 1 7 Figure 1 1 Cisco MDS 9222i Chassis 184704 1 3 4 2 1 Fan module 3 Supervisor module with integrate...

Страница 22: ...ssis MDS 9216i GE 1 LIN K GE 2 LIN K 5 6 7 8 9 10 11 12 13 14 1 2 3 4 116888 4 2 3 1 1 Fan module 3 Supervisor module with integrated 14 port Fibre Channel and 2 port Gigabit Ethernet switching module 2 Switching module or Services module such as the IPS module 4 Interface module 1 Fan module 3 Supervisor module with integrated 16 port Fibre Channel switching module 2 Switching module or Services ...

Страница 23: ...r modules in each chassis These modules include the following Cisco MDS 9222i Integrated Supervisor Module page 1 5 Cisco MDS 9216i Integrated Supervisor Module page 1 6 Cisco MDS 9216A Integrated Supervisor Module page 1 7 Cisco MDS 9222i Integrated Supervisor Module The nonremovable Cisco MDS 9222i integrated supervisor module provides the control and management functions of the Cisco MDS 9222i ...

Страница 24: ...void a single point of failure Note For a description of the integrated 14 2 port Multiprotocol Services module and its capabilities see the 14 2 Port Multiprotocol Services Module section on page 1 23 Figure 1 5 shows the Cisco MDS 9216i integrated supervisor module with an integrated 14 port Fibre Channel and 2 port Gigabit Ethernet module Figure 1 5 Cisco MDS 9216i Supervisor Module with Integr...

Страница 25: ...ingle point of failure Note For a description of the integrated 16 port switching module and its capabilities see the 16 Port 2 Gbps Fibre Channel Switching Module section on page 1 17 Figure 1 6 shows the Cisco MDS 9216A supervisor module with an integrated 16 port Switching module Figure 1 6 Cisco MDS 9216A Supervisor Module with Integrated 16 Port Switching Module The Cisco MDS 9216A integrated...

Страница 26: ...d the maximum system operating temperature limit a minor environmental warning To ensure maximum product life you should immediately correct the environmental temperature and restore the system to normal operation Red One of the following occurred The diagnostic test failed The module is not operational because a fault occurred during the initialization sequence The inlet air temperature of the sy...

Страница 27: ...et port with an RJ 45 connection that provides network management capabilities RS 232 COM1 port with a DB 9 connector that can be attached to a modem Figure 1 7 Nonremoveable Interface Module of the Cisco MDS 9200 Series The clock module is also part of the interface module Note The system clocks in the Cisco MDS 9200 Series have a field measured mean time between failures MTBF of approximately 3 ...

Страница 28: ...ning To ensure maximum product life you should immediately correct the environmental temperature and restore the system to normal operation Red One of the following occurred The diagnostic test failed The module is not operational because a fault occurred during the initialization sequence The inlet air temperature of the system exceeded the safe operating temperature limits of the card a major en...

Страница 29: ... Platform Compatibility Matrix Module 9513 9509 9506 9222i 9216A 9216i 9216 Supervisor 2 module X X X Supervisor 1 module X X 16 port Storage Services module SSN 16 X X X X 4 44 port 8 Gbps Host Optimized Fibre Channel switching module X X X X 48 port 4 Gbps Fibre Channel switching module X X X X X X 24 port 4 Gbps Fibre Channel switching module X X X X X X 12 port 4 Gbps Fibre Channel switching m...

Страница 30: ...d on the modules are not field replaceable units Do not remove or replace internal bootflash on the modules Modifying the factory installed bootflash is not supported 4 44 Port 8 Gbps Host Optimized Fibre Channel Switching Module The 4 44 port 8 Gbps Host Optimized Fibre Channel switching module offers 48 autosensing 1 2 4 and 8 Gbps Fibre Channel ports and can be used in any of the Cisco MDS 9500...

Страница 31: ...EDs 24 Port 4 Gbps Fibre Channel Switching Module The 24 port 4 Gbps Fibre Channel switching module offers 24 autosensing 1 2 and 4 Gbps Fibre Channel ports and can be used in any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9216i and 9216A Switches The 24 port switching module can be configured in one of two operational modes shared bandwidth mode default and dedicated bandwidth mode...

Страница 32: ...ate mode module providing 12 SFP based Fibre Channel interfaces Each interface can support full line rate operation at 4 Gbps interface speed The module delivers a sustained data rate of up to 4 Gbps in each direction on all ports simultaneously and up to 96 Gbps of continuous aggregate bandwidth when attached to high performance servers and storage subsystems Figure 1 12 shows a 12 port 4 Gbps Fi...

Страница 33: ... 10 Gbps with no oversubscription This module can be used in any of the Cisco MDS 9500 Series chassis and in the Cisco MDS 9216i and 9216A Switches The module delivers a sustained data rate of up to 10 Gbps in each direction on all ports simultaneously and up to 80 Gbps of continuous aggregate bandwidth Figure 1 13 shows a 4 port 10 Gbps switching module The front panel connectors are standard mod...

Страница 34: ... shows a 32 port switching module Table 1 4 LEDs for the Cisco MDS 9000 Family Generation 2 Fibre Channel Switching Modules LED Status Description Status Green All diagnostics pass The module is operational normal initialization sequence Orange One of the following occurs or occurred The module is booting or running diagnostics normal initialization sequence The inlet air temperature of the system...

Страница 35: ...ance host or storage controllers The 16 port switching module supports a sustained data rate of up to 2 Gbps in each direction on all ports simultaneously Figure 1 15 shows a 16 port 2 Gbps switching module The autosensing 1 Gbps 2 Gbps ports of the 16 port Fibre Channel switching module deliver up to 64 Gbps of continuous aggregate bandwidth when attached to high performance servers and storage s...

Страница 36: ...upervisor module and displays an alarm on its front panel when a problem is detected The front panel on the switching module provides basic status information such as power on self test running self test passed alarm and ready The binary image for the switching module is downloaded from the supervisor module Prior to the image download the control processor on the switching module runs from code s...

Страница 37: ... minor environmental warning To ensure maximum product life you should immediately correct the environmental temperature and restore the system to normal operation Red One of the following occurs or occurred The diagnostic test failed The module is not operational because a fault occurred during the initialization sequence The inlet air temperature of the system has exceeded the safe operating tem...

Страница 38: ...rage Services Module The Cisco MDS 9000 Family 16 port Storage Services module SSN 16 provides 16 Gigabit Ethernet IP services ports The SSN 16 module provides 16 1 Gigabit Ethernet ports and supports features such as I O Accelerator Storage Media Encryption and Fiber Channel over IP The SSN 16 module acts as a service blade for the storage applications The module provides 16 Gigabit front panel p...

Страница 39: ...appable shortwave longwave small form factor pluggables SFPs Integrated hardware based virtual SANs VSANs and Inter VSAN Routing IVR The module enables deployment of large scale multisite and heterogeneous SAN topologies Integration into port level hardware allows any port within a system or fabric to be partitioned into any VSAN Integrated hardware based IVR provides line rate routing between any...

Страница 40: ... The MSM 18 4 module provides 18 4 Gbps Fibre Channel interfaces for high performance SAN and mainframe connectivity and four Gigabit Ethernet ports for FCIP and iSCSI storage services Individual ports can be configured with hot swappable short wavelength long wavelength extended reach coarse wavelength division multiplexing CWDM or dense wavelength division multiplexing DWDM Small Form Factor Plu...

Страница 41: ... and 2 provide 1 Gbps throughput for IP services including iSCSI and FCIP over Gigabit Ethernet The MPS 14 2 also supports hardware based encryption and compression for these Gigabit Ethernet ports This hardware based encryption handles the computationally intensive IPsec feature for IP services Table 1 6 LEDs for the Cisco MDS 9000 Family 18 4 Port Multiservice Modules LED Status Description Stat...

Страница 42: ...Fabric Manager Interfaces Configuration Guide The Fibre Channel port interfaces support hot swappable Fibre Channel SFP transceivers which can be short wavelength SWL for connectivity up to 1640 feet 500 meters or long wavelength LWL for connectivity up to 6 2 miles 10 km All interfaces are autosensing 1 Gbps or 2 Gbps compatible The port interfaces also support coarse wavelength division multiple...

Страница 43: ...ble 1 7 LEDs for the Cisco MDS 9000 Family MPS 14 2 Modules LED Status Description Status Green All diagnostics pass The module is operational normal initialization sequence Orange One of the following occurs or occurred The module is booting or running diagnostics normal initialization sequence The inlet air temperature of the system exceeded the maximum system operating temperature limit a minor...

Страница 44: ...connectivity up to 6 2 miles 10 km The port interfaces also support coarse wavelength division multiplexing CWDM SFP transceivers which can be used for extended long wavelength ELWL transmission or for CWDM See the Supported Transceivers section on page 1 36 Figure 1 18 shows an IPS 8 module Figure 1 18 Cisco MDS 9000 Family IPS 8 Module Figure 1 19 shows an IPS 4 module Figure 1 19 Cisco MDS 9000...

Страница 45: ...diagnostics pass The module is operational normal initialization sequence Orange One of the following occurs or occurred The module is booting or running diagnostics normal initialization sequence The inlet air temperature of the system exceeded the maximum system operating temperature limit a minor environmental warning To ensure maximum product life you should immediately correct the environment...

Страница 46: ... source and temperature The control processor signals the supervisor module and displays an alarm on its front panel when it detects a problem The front panel on the services module provides basic status information such as power on self test running self test passed alarm and ready The binary image for the services module is downloaded from the supervisor module Prior to the image download the co...

Страница 47: ...cription Status Green All diagnostics pass The module is operational normal initialization sequence Orange One of the following occurs or occurred The module is booting or running diagnostics normal initialization sequence The inlet air temperature of the system exceeded the maximum system operating temperature limit a minor environmental warning To assure maximum product life you should immediate...

Страница 48: ...ocessor signals the supervisor module and displays an alarm on its front panel when a problem is detected The front panel on the services module provides basic status information such as power on self test running self test passed alarm and ready The binary image for the services module is downloaded from the supervisor module Prior to the image download the control processor on the switching modu...

Страница 49: ...00 Family ASM LED Status Description Status Green All diagnostics pass and the module is operational normal initialization sequence Orange One of the following occurs or occurred The module is booting or running diagnostics normal initialization sequence The inlet air temperature of the system exceeded the maximum system operating temperature limit a minor environmental warning To ensure maximum p...

Страница 50: ...ry to the disk drives and then shuts down The CSM batteries provide adequate power to back up data without external power Figure 1 22 shows the Cisco MDS 9000 Family CSM Figure 1 22 Cisco MDS 9000 Family CSM Figure 1 23 shows the location of the disk drives and batteries on the CSM Caution The batteries are shipped fully charged and should be handled accordingly 1 Status LED 5 Disk 1 Status LED 2 ...

Страница 51: ...de OL 19588 01 Chapter 1 Product Overview Services Modules Figure 1 23 Cisco MDS 9000 Family CSM Internal View See the Removing and Installing Switching and Services Modules section on page 2 28 for information about removing and installing the CSM and maintaining the CSM batteries 1 Disk drive 2 3 Battery 2 2 Disk drive 1 4 Battery 1 94038 1 3 4 2 ...

Страница 52: ...iagnostic test failed The module is not operational because a fault occurred during the initialization sequence The inlet air temperature of the system exceeded the safe operating temperature limits of the card a major environmental warning The card shut down to prevent permanent damage Node Green Node is fully operational Flashing green Node is not yet part of a cluster Orange The module is booti...

Страница 53: ...The power supplies which are accessed from the rear of the chassis are illustrated in Figure 1 24 Figure 1 24 Cisco MDS 9200 Series with 845 W Dual Power Supplies Table 1 12 describes the LEDs for the Cisco MDS 9200 Series power supplies 1 Power supply switch 3 Power supply handle 2 AC power connection 4 Power supply LEDs PWR 845 AC 100 240V 12 5A 50 60 Hz INPUT OK FAN OK OUTPUT FAIL ALL FASTENERS...

Страница 54: ...y has failed Caution The Cisco MDS 9000 Family switches have internal temperature sensors that are capable of shutting down the system if the temperature at different points within the chassis exceed certain safety thresholds To be effective the temperature sensors require the presence of airflow therefore in the event a fan module is removed from the chassis the Cisco MDS 9000 Family switches shu...

Страница 55: ...ecifications see the X2 Transceiver Specifications section on page B 7 Fibre Channel SFP Transceivers Cisco Fibre Channel SFP transceivers are available in SWL or LWL versions Both of these versions are 1 Gbps 2 Gbps 4 Gbps capable Cisco Fibre Channel SFP transceivers are available in SWL or LWL versions Both of these versions are 2 Gbps 4 Gbps 8 Gbps capable Cisco Fibre Channel SFP transceivers h...

Страница 56: ... received transmissions into the different wavelengths and sends them to the corresponding CWDM SFP transceiver For more information on the CWDM SFP transceiver specifications see the SFP and SFP Transceiver Specifications section on page B 10 Gigabit Ethernet SFP Transceivers The 4 port and 8 port IP Storage services IPS 4 and IPS 8 modules provide four or eight 1 Gigabit Ethernet ports that supp...

Страница 57: ...atory Compliance and Safety Information for the Cisco MDS 9000 Family for important safety information Warning IMPORTANT SAFETY INSTRUCTIONS This warning symbol means danger You are in a situation that could cause bodily injury Before you work on any equipment be aware of the hazards involved with electrical circuitry and be familiar with standard practices for preventing accidents Use the stateme...

Страница 58: ... with the switch The telco and EIA Shelf Bracket Kit an optional kit purchased separately in addition to the rack mount kit shipped with the switch In a perforated or solid walled EIA cabinet using The rack mount kit shipped with the switch The telco and EIA Shelf Bracket Kit an optional kit purchased separately in addition to the rack mount kit shipped with the switch In a two post telco rack usi...

Страница 59: ...per Power Cord section on page C 11 Ensure that the chassis is adequately grounded If the switch is not mounted in a grounded rack Cisco recommends connecting both the system ground on the chassis and the power supply ground to an earth ground Ensure that the site power meets the power requirements listed in Appendix B Technical Specifications If available you can use an uninterruptible power supp...

Страница 60: ...ting the Switch Caution When handling switch components wear an ESD strap and handle modules by the carrier edges only An ESD socket is provided on the chassis For the ESD socket to be effective the chassis must be grounded through the power cable the chassis ground or the metal to metal contact with a grounded rack Tip Keep the shipping container in case the chassis requires shipping in the futur...

Страница 61: ...on wheels ensure that the brakes are engaged or that the rack is otherwise stabilized The rack mount kit provided with the switch contains the items listed in Table 2 1 If you do not find all the parts listed in Table 2 1 you may have an older version of the rack mount kit which only included the front rack mount brackets If this is the case you can either install the switch in the rack with just ...

Страница 62: ...gainst the chassis and align the screw holes as shown in Figure 2 1 Then attach the front rack mount bracket to the chassis with six of the M4 screws b Repeat with the other front rack mount bracket on the other side of the switch Figure 2 1 Attaching Front Rack Mount Bracket to the Cisco MDS 9200 Series 2 C brackets 6 12 24 x 3 4 inch Phillips binder head screws 6 10 32 x 3 4 inch Phillips binder...

Страница 63: ...the screw holes as shown in Figure 2 2 and Figure 2 3 Then attach the bracket to the switch with two of the flat head M4 screws Note Ensure the C bracket is oriented so that it blocks the fewest airflow holes on the chassis the holes should be slightly closer to the bottom of the brackets and the text on the back of the bracket should be right side up b Repeat with the other C bracket on the other...

Страница 64: ...e e d b a ck d o c c i s c o c o m 2 8 Cisco MDS 9200 Series Hardware Installation Guide OL 19588 01 Chapter 2 Installing the Cisco MDS 9200 Series Installing the Chassis in a Cabinet or Rack Figure 2 3 C Brackets for the Cisco MDS 9200 Series Close Up View 94297 ...

Страница 65: ...he front rack mount brackets and then pass the screws through the cable guides front rack mount brackets and mounting rail You can install one or both cable guides if installing a single cable guide it can be installed on either side Figure 2 4 Installing the Cisco MDS 9200 Series in the Rack Step 4 From the back of the rack position the longer slider rails with the ears away from the chassis and ...

Страница 66: ...c o c o m 2 10 Cisco MDS 9200 Series Hardware Installation Guide OL 19588 01 Chapter 2 Installing the Cisco MDS 9200 Series Installing the Chassis in a Cabinet or Rack Figure 2 5 Inserting and Installing Slider Rails Back View 1 Screws 12 24 or 10 32 3 C bracket 2 Slider rail 99001 1 2 3 ...

Страница 67: ... clearance The Cisco MDS 9200 Series is installed rear facing to provide adequate clearance for the fiber optic cables This cabinet meets the requirements described in Appendix A Cabinet and Rack Installation except the cabinet has less than three inches of clearance between the inside of the front door or bezel panel and the front cabinet mounting rails This rear facing installation is necessary ...

Страница 68: ...d support directly from Cisco contact Cisco Technical Support at this URL http www cisco com warp public 687 Directory DirTAC shtml Installing Front Rack Mount Brackets for Cabinets with 26 Inches or Greater of Rail Spacings Before installing the switch into the cabinet the front rack mount brackets for the Cisco MDS 9200 Series must be installed onto the switch To install the brackets for cabinet...

Страница 69: ... Insufficient Front Clearance Step 2 Install the C brackets on the switch as follows a Position one of the C brackets against the side of the switch and align the screw holes as shown in Figure 2 8 and Figure 2 9 Then attach the bracket to the switch with two of the flat head M4 screws Figure 2 8 Installing C Brackets onto the Cisco MDS 9200 Series 1 C bracket 2 Screws M4 MDS 9216i GE 1 LIN K GE 2...

Страница 70: ...Rack Mount Brackets for Cabinets with Less Than 26 Inches of Rail Spacings The front rack mount brackets for the Cisco MDS 9200 Series switch must be installed onto the switch prior to installing the switch into the cabinet For cabinets with less than 26 inches of rail to rail spacing the front rack mount bracket must be installed 180 degrees from normal To install the brackets for cabinets with f...

Страница 71: ...epeat with the other front rack mount bracket on the other side of the switch Step 2 Install the C brackets on the switch as follows a Position one of the C brackets against the side of the switch and align the screw holes as shown in Figure 2 11 and Figure 2 12 Then attach the bracket to the switch with two of the flat head M4 screws Figure 2 11 Installing C Brackets onto the Cisco MDS 9200 Serie...

Страница 72: ...ch Installing the Cisco MDS 9200 Series Rear Facing into Cabinet To install the switch rear facing into a cabinet using the rack mount kit provided with the switch for cabinets with insufficient front facing clearance follow these steps Step 1 Position the chassis in the rack inserting the back of the chassis between the rear mounting rails see Figure 2 13 Use the 12 24 x 3 4 in or 10 32 x 3 4 in ...

Страница 73: ...ing the Cisco MDS 9200 Series Rear Facing in the Rack Step 2 From the front of the rack position the longer slider rails with the ears away from the chassis and slide them into the C brackets previously installed on the sides of the chassis see Figure 2 14 Step 3 Level the chassis it may sag slightly towards the back and attach the slider rails to the mounting rails with the 12 24 x 3 4 in or 10 3...

Страница 74: ...n a Cabinet with Insufficient Front Clearance Figure 2 14 Inserting and Installing Slider Rails Front View Figure 2 15 shows the Cisco MDS 9200 Series completely installed in a rack Note Figure 2 15 shows the front rack mount brackets as rotated Your chassis may have these brackets installed in the normal position 1 Screws 12 24 or 10 32 3 C bracket 2 Slider rail 113444 1 2 3 Rear cabinet mounting...

Страница 75: ...atic discharge Proper Grounding Practices Grounding is one of the most important parts of equipment installation Proper grounding practices ensure that the buildings and the installed equipment within them have low impedance connections and low voltage differentials between chassis When you properly ground systems during installation you reduce or prevent shock hazards equipment damage due to tran...

Страница 76: ...uch as welding Medium to high Best grounding practices must be closely followed Existing commercial building is not subject to natural environmental noise or man made industrial noise This building contains a standard office environment This installation has a history of malfunction due to electromagnetic noise Medium Best grounding practices must be closely followed Determine source and cause of ...

Страница 77: ...9200 series chassis are equipped with a banana plug connector identified by the ground symbol next to the connector somewhere on the front panel Cisco recommends that you use a personal ESD grounding strap equipped with a banana plug If you choose to use the disposable ESD wrist strap supplied with most FRUs or an ESD wrist strap equipped with an alligator clip you must attach the system ground lu...

Страница 78: ...rap that is supplied with the FRUs squeeze the spring clip jaws open position the spring clip to one side of the system ground lug screw head and slide the spring clip over the lug screw head so that the spring clip jaws close behind the lug screw head Note The spring clip jaws do not open wide enough to fit directly over the head of the lug screw or the lug barrel b If you are using an ESD wrist ...

Страница 79: ...les and is intended to satisfy the telcordia Technologies NEBS requirements for supplemental bonding and grounding connections You must observe the following system grounding guidelines for your chassis You must install the system NEBS ground connection with any other rack or system power ground connections that you make The system ground connection is required if this equipment is installed in a ...

Страница 80: ...a grounding pad with two threaded M4 holes for attaching a grounding lug Figure 2 17 shows the system ground location on the Cisco MDS 9200 Series Warning When installing or replacing the unit the ground connection must always be made first and disconnected last Statement 1046 Caution Cisco recommends grounding the chassis even if the rack is already grounded Caution All power supplies must be gro...

Страница 81: ...tatement 1046 Caution Grounding the chassis is required if you are using DC power supplies even if the rack is already grounded A grounding pad with two threaded M4 holes is provided on the chassis for attaching a grounding lug The ground lug must be NRTL listed In addition the copper conductor wires must be used and the copper conductor must comply with NEC code for ampacity 1 ESD socket on switc...

Страница 82: ... the system is operating Use caution when servicing Statement 1034 Warning Blank faceplates and cover panels serve three important functions they prevent exposure to hazardous voltages and currents inside the chassis they contain electromagnetic interference EMI that might disrupt other equipment and they direct the flow of cooling air through the chassis Do not operate the system unless all cards...

Страница 83: ...ould begin operating when the switch is powered on Caution Do not operate the switch without a functioning fan module except for during the brief fan module replacement procedure Cisco MDS 9000 Family switches can operate for only a few minutes without any functioning fan modules before they begin to overheat Step 8 After the switch boots verify that the LED behavior is as follows Fan module Statu...

Страница 84: ...ugh the basic configuration For instructions on how to configure the switch and check module connectivity see the Cisco MDS 9000 Family NX OS Interfaces Configuration Guide or the Cisco Fabric Manager Interfaces Configuration Guide Removing and Installing Components This section includes the following topics Removing and Installing Switching and Services Modules page 2 28 Maintaining a Caching Ser...

Страница 85: ...g Statement 1034 Caution To prevent ESD damage wear grounding wrist straps during these procedures and handle modules by the carrier edges only Note Install the Cisco MDS 9200 Series in the rack before installing modules For information about installing the chassis see the Installing the Chassis in a Cabinet or Rack section on page 2 5 This section includes the following topics Removing a Caching ...

Страница 86: ...uide OL 19588 01 Chapter 2 Installing the Cisco MDS 9200 Series Removing and Installing Components Figure 2 18 Positioning the Module in the Chassis MDS 9216i GE 1 LIN K GE 2 LIN K 5 6 7 8 9 10 11 12 13 14 1 2 3 4 EMI gasket STATUS DS X9032 1 2 G FC Module EMI gasket Insert module between slot guides 4 3 2 1 6 117000 Ejector lever fully extended ...

Страница 87: ... and data backup Warning Do not touch or bridge the metal contacts on the battery Unintentional discharge of the batteries can cause serious burns Statement 341 Warning Ultimate disposal of this product should be handled according to all national laws and regulations Statement 1040 Caution Wait for all LEDs to turn off before removing the module from the chassis If the LEDs are on the module still...

Страница 88: ...ller panel to keep dust out of the chassis and maintain consistent airflow if the slot will remain empty Warning Blank faceplates and cover panels serve three important functions they prevent exposure to hazardous voltages and currents inside the chassis they contain electromagnetic interference EMI that might disrupt other equipment and they direct the flow of cooling air through the chassis Do n...

Страница 89: ...lling the Chassis in a Cabinet or Rack section on page 2 5 To install a module in slot 2 of the chassis follow these steps Step 1 Verify that there is enough clearance to accommodate any interface equipment that you connect directly to the nearby components Step 2 If a filler panel is installed remove the two Phillips pan head screws from the filler panel and remove the panel To remove a currently...

Страница 90: ...le To verify the module installation in slot 2 follow these steps Step 1 Verify that the ejector levers of the module are fully closed parallel to the faceplate to ensure that the module is fully seated in the backplane connectors Step 2 Check the captive screws of the module the power supply and the fan module and tighten any loose captive screws Step 3 Verify that a filler panel is installed and...

Страница 91: ...st be replaced Caution The CSM batteries are shipped fully charged and should be handled accordingly Warning Do not touch or bridge the metal contacts on the battery Unintentional discharge of the batteries can cause serious burns Statement 341 Warning Ultimate disposal of this product should be handled according to all national laws and regulations Statement 1040 The batteries are automatically c...

Страница 92: ...tement 289 Note You can replace a faulty power supply while the system is operating provided the other power supply is functioning Removing a Power Supply To remove a power supply follow these steps Step 1 Turn the power switch to the off 0 position Step 2 Loosen the screw on the power cable retainer and disconnect the power cable from the power supply being removed Step 3 Loosen the captive screw...

Страница 93: ... the power supply captive screws Step 6 Plug the power cable into the power supply and tighten the screw on the power cable retainer to ensure the cable cannot be pulled out Note Depending on the outlet receptacle on your power distribution unit you may need the optional jumper power cord to connect the Cisco MDS 9200 Series to your outlet receptacle See the Jumper Power Cord section on page C 11 ...

Страница 94: ...ed to be removed and replaced while the system is operating without presenting an electrical hazard or damage to the system provided the replacement is performed promptly This section includes the following topics Removing a Fan Module page 2 39 Installing a Fan Module page 2 39 You will need a flat blade or number 2 Phillips screwdriver to perform these procedures Caution The Cisco MDS 9000 Famil...

Страница 95: ...r 2 Phillips screwdriver if required Step 2 Grasp the fan module with both hands and pull it outward rock it gently if necessary to unseat the power connector from the backplane Step 3 Pull the fan module clear of the chassis Caution If the switch is powered on you must hot swap another fan module into this switch within five minutes Installing a Fan Module To install a fan module follow these ste...

Страница 96: ...chnical Support at this URL http www cisco com warp public 687 Directory DirTAC shtml Removing the Cisco MDS 9200 Series When removing the Cisco MDS 9200 Series from the rack remove the slider brackets first and then the front screws fastening the front rack mount brackets to the rack Note The slider rail and C brackets do not have a stop mechanism when sliding in and out If the front of the chass...

Страница 97: ...e Channel ports that you can use to connect to the SAN or for in band management Other port types provided by the optional module if installed such as the iSCSI and or FCIP over Gigabit Ethernet ports on the 4 port or 8 port IPS modules Caution When running power and data cables in overhead or subfloor cable trays Cisco strongly recommends that power cables and other potential noise sources must b...

Страница 98: ... transmission Cisco recommends using this port to create a local management connection to set the IP address and other initial configuration settings before connecting the switch to the network for the first time Caution The console port can be used to connect to a modem however Cisco recommends using the COM1 port for this purpose If you decide to connect the console port to a modem do not connec...

Страница 99: ...nsole port to a computer terminal follow these steps Step 1 Configure the terminal emulator program to match the following default port characteristics 9600 baud 8 data bits 1 stop bit no parity Step 2 Connect the supplied RJ 45 to DB 9 female adapter or RJ 45 to DB 25 female adapter depending on your computer serial port to the computer serial port Cisco recommends using the adapter and cable pro...

Страница 100: ...ure 3 2 Connecting to the COM1 Port on the Cisco MDS 9200 Series To connect the COM1 port to a modem follow these steps Step 1 Connect the DB 9 serial adapter to the COM1 port Note Connect the modem to the COM1 port using the adapters and cables provided with the accessory kit Step 2 Connect the RJ 45 to DB 25 modem adapter to the modem Step 3 Connect these two adapters using the RJ 45 to RJ 45 ro...

Страница 101: ...sco Fabric Manager Interfaces Configuration Guide The MGMT 10 100 Ethernet port is autosensing and has an RJ 45 interface See Figure 3 3 You can use this port to access and manage the switch by its IP address such as through the Cisco Fabric Manager Figure 3 3 Connecting to the MGMT 10 100 Ethernet Port on the Cisco MDS 9200 Series To connect the MGMT 10 100 Ethernet port to an external hub switch...

Страница 102: ...isconnected fibers or connectors Do not stare into beams or view directly with optical instruments Statement 1051 Caution Wear an ESD wrist strap connected to the chassis when handling transceivers Keep optical connectors covered when not in use and do not touch connector ends The fiber optic connectors must be free of dust oil and other contaminants This section includes the following topics Remo...

Страница 103: ... Port The Cisco MDS 9000 Family supports X2 transceivers with SC connectors See Figure 3 4 Figure 3 4 Cisco MDS 9000 Family X2 Transceivers 1 Transmit optical bore 6 Module connector 2 Receive optical bore 7 Latch extended 3 Latching sleeve retracted 8 Latching sleeve extended 4 EMI gasket 9 Latch retracted 5 Transceiver heat sink 5 6 120754 4 3 8 1 2 7 9 Latching sleeve retracted latch extended L...

Страница 104: ...strap and follow its instructions for use Step 2 If a cable is installed in the transceiver a Record the cable and port connections for later reference b Press the release latch on the cable grasp the connector near the connection point and gently pull the connector from the transceiver c Insert a dust plug into the cable end of the transceiver Caution If the transceiver does not remove easily in ...

Страница 105: ...FP Transceiver with Mylar Tab Latch Figure 3 6 SFP Transceiver with Bale Clasp Latch Installing an SFP Transceiver To install an SFP transceiver follow these steps Step 1 Attach an ESD preventive wrist strap and follow its instructions for use Step 2 Remove the dust cover from the port cage Step 3 Remove the dust cover from the port end of the transceiver Step 4 Insert the transceiver into the por...

Страница 106: ...ll the connector from the transceiver c Insert a dust plug into the cable end of the transceiver Caution If the transceiver does not remove easily in the next step push the transceiver completely in and then ensure that the latch is in the correct position before continuing Step 3 Remove the transceiver from the port If the transceiver has a Mylar tab latch gently pull the tab straight out do not ...

Страница 107: ...ceivers Caution To prevent damage to the fiber optic cables do not place more tension on them than the rated limit and do not bend to a radius of less than 1 inch if there is no tension in the cable or 2 inches if there is tension in the cable Installing a Cable into an SFP Transceiver Caution To prevent possible damage to the cable or transceiver install the transceiver in the port before install...

Страница 108: ...guration Guide Removing a Cable from an SFP Transceiver Caution When pulling a cable from a transceiver grip the body of the connector Do not pull on the jacket sleeve because this can compromise the fiber optic termination in the connector Caution If the cable does not remove easily ensure that any latch present on the cable has been released before continuing To remove the cable follow these ste...

Страница 109: ...preventive wrist strap that is connected to the chassis Do not remove and insert a transceiver more often than is necessary Repeated removals and insertions can shorten its useful life Keep all optical connections covered when not in use If they become dusty clean before using to prevent dust from scratching the fiber optic cable ends Do not touch ends of connectors to prevent fingerprints and oth...

Страница 110: ...t a t i o n c o m m e n t s t o m d s f e e d b a ck d o c c i s c o c o m 3 14 Cisco MDS 9200 Series Hardware Installation Guide OL 19588 01 Chapter 3 Connecting the Cisco MDS 9200 Series Connecting to a Fibre Channel Port ...

Страница 111: ...andard open racks telco racks Note If you are selecting an enclosed cabinet Cisco recommends one of the thermally validated types standard perforated or solid walled with a fan tray Note Do not use racks that have obstructions such as power strips because the obstructions could impair access to field replaceable units FRUs General Requirements for Cabinets and Racks The cabinet or rack must be one...

Страница 112: ...installation A minimum of 2 5 in 6 4 cm of clear space should exist between the side edge of the chassis and the side wall of the cabinet No sizeable flow obstructions should be immediately in the way of chassis air intake or exhaust vents Note Optional jumper power cords are available for use in a cabinet See the Jumper Power Cord section on page C 11 Requirements Specific to Perforated Cabinets ...

Страница 113: ...e of equipment should be installed a minimum of 1 75 in 4 4 cm above the floor openings to prevent blocking the floor intake Requirements Specific to Standard Open Racks In addition to the requirements listed in the General Requirements for Cabinets and Racks section on page A 1 if mounting the chassis in an open rack no side panels or doors ensure that the rack meets the following requirements Th...

Страница 114: ... 7 Installing the Switch on the Shelf Brackets page A 8 Removing the Shelf Bracket Kit Optional page A 9 Note This optional kit is not provided with the switch to order the kit contact your switch supplier Note For additional support after removing the shelf brackets ensure that the C brackets on the Cisco MDS 9200 Series are attached to the rear rack mounting rails Rack Mounting Guidelines Cautio...

Страница 115: ...ng the shelf brackets check the contents of your kit Table A 1 lists the contents of the optional shelf bracket kit Required Equipment You need the following equipment for this installation Number 2 Phillips screwdriver Tape measure and level to ensure shelf brackets are level Rack Type MDS 9513 MDS 9509 MDS 9506 MDS 9222i MDS 9216i MDS 9216A MDS 9100 EIA 4 Post 45 lb 20 41 kg 45 lb 20 41 kg 30 lb...

Страница 116: ...et inside a rack mounting rail as shown in Figure A 1 Align the screw holes at the front of the shelf bracket with the holes in the rack mounting rail Then attach the shelf bracket to the rack mounting rail using a minimum of four 12 24 or 10 24 screws Note The bottom hole of the shelf bracket should align with the bottom hole of a rack unit on the rack mounting rail the hole immediately above the...

Страница 117: ...steps Step 1 Position a shelf bracket inside the rack mounting rails as shown in Figure A 2 Align the screw holes at the front of the shelf bracket with the holes in the front rack mounting rail Then attach the shelf bracket to the front rack mounting rail using a minimum of four 12 24 or 10 24 screws Note The bottom hole of the shelf bracket should align with the bottom hole of a rack unit on the...

Страница 118: ...access area can be accessed only through the use of a special tool lock and key or other means of security Statement 1017 Warning Only trained and qualified personnel should be allowed to install replace or service this equipment Statement 1030 Note Before you install operate or service the system refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family for important...

Страница 119: ...ront rack mount brackets are securely attached to the rack mounting rails For additional support in an EIA rack ensure that the C brackets on the Cisco MDS 9200 Series are attached to the rear rack mounting rails To remove the shelf bracket kit follow these steps Step 1 Remove the screws fastening the slider brackets to the rear rack mounting rails Then slide the slider brackets out of the shelf b...

Страница 120: ... i o n c o m m e n t s t o m d s f e e d b a ck d o c c i s c o c o m A 10 Cisco MDS 9200 Series Hardware Installation Guide OL 19588 01 Appendix A Cabinet and Rack Installation Cisco MDS 9000 Family telco and EIA Shelf Bracket ...

Страница 121: ...s Switch Specifications This section provides switch specifications for theCisco MDS 9200 Series Table B 1 lists the environmental specifications for the Cisco MDS 9200 Series Table B 1 Environmental Specifications for the Cisco MDS 9200 Series Description Specification Temperature certified for operation 32 to 104 F 0 to 40 C Temperature designed and tested for operation 32 to 130 F 0 to 55 C Tem...

Страница 122: ...two power supplies 53 3 lb 24 3 kg Power supply 845 W AC input for each power supply Airflow 300 lfm2 through system fan module or 80 cfm3 per supervisor switching or services module Total of 160 cfm if slot 2 is filled Spacing requirements If installed in a cabinet a minimum of 2 5 in 6 4 cm is required between the chassis air vents and the cabinet walls If installed in an open rack no side panel...

Страница 123: ...on Table B 4 Caching Services Module Battery Specifications Description Specification Nominal voltage 9 6 V Rated capacity Typical discharge capacity at 0 2C rate 2100 mAh Minimum discharge capacity at 0 2C rate 2000 mAh Minimum discharge capacity at 5C rate 1800 mAh 1V cell discharge cut off Discharge The battery is capable of continuous discharge from 41 to 140 F 5 to 60 C at 5C rate Charge From...

Страница 124: ...nd accepts AC input 16 port FC switching module 9 lb 4 1 kg SSM 11 lb 5 kg CSM 11 5 lb 5 2 kg ASM 11 lb 5 kg IPS 8 10 lb 4 5 kg IPS 4 9 lb 4 1 kg MSM 18 4 8 5 lb 3 86 kg MPS 14 2 10 lb 4 5 kg Supervisor 2 for MDS 9500 Series 7 25 lb kg Supervisor 1 for MDS 9500 Series 9 lb 4 1 kg Supervisor for MDS 9200 Series 9 lb 4 1 kg Module blank panels 0 50 lb 0 25 kg Table B 5 Weight of Modules in the Cisco...

Страница 125: ... OS Release Power Required watts Heat Dissipation BTU hr Input Current 90 VAC amps 120 VAC amps 180 VAC amps 240 VAC amps Cisco MDS 9222i chassis with fan module DS C9222i K9 3 2 1 60 256 0 83 0 63 0 42 0 31 Cisco MDS 9222i fixed supervisor module 18 port Fibre Channel and 4 port Gigabit Ethernet module 3 2 1 200 855 2 78 2 08 1 39 1 04 Cisco MDS 9216i chassis with fan module DS C9216i K9 3 x 60 2...

Страница 126: ... 53 1 15 MSM 18 4 module DS X9304 18K9 3 2 1 200 855 2 78 2 08 1 39 1 04 MPS 14 2 DS X9302 14K9 3 x 200 854 2 78 2 08 1 39 1 04 2 x and 1 x 227 970 3 15 2 37 1 57 1 19 8 port IPS module DS X9308 SMIP 3 x 200 854 2 78 2 08 1 39 1 04 2 x and 1 x 220 940 3 05 2 29 1 53 1 15 4 port IPS module DS X9304 SMIP 3 x 160 683 2 22 1 67 1 11 0 83 2 x and 1 x 185 789 2 57 1 93 1 28 0 96 32 port SSM DS X9032 SSM...

Страница 127: ...ibre Channel X2 Transceivers Table B 8 lists the Cisco10 Gbps Fibre Channel X2 transceivers General Specification for Cisco 10 Gbps Fibre Channel X2 Transceivers Table B 9 provides the general specifications for Cisco 10 Gbps Fibre Channel X2 transceivers Note The minimum cable distance for all the transceivers such as multimode fiber MMF and single mode fiber SMF except CX4 is 2 meters 6 5 feet T...

Страница 128: ...o the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family Cisco 10 Gbps Ethernet X2 Transceivers Table B 12 lists the Cisco 10 Gbps Ethernet X2 transceivers Table B 10 Power Requirement Specifications for Cisco 10 Gbps Fibre Channel X2 Transceivers X2 Average Transmit Power dBm Average Receive Power dBm Fiber Loss Budget dBm Maximum Minimum Maximum Minimum DS X2 FC10G SR 1 2...

Страница 129: ...eiver The Cisco 10 Gbps Ethernet DWDM X2 Transceiver pluggable module DWDM X2 xx xx provides high performance Fibre Channel connectivity for the Cisco MDS 9000 Family 10 Gbps Fibre Channel switching module to an existing Ethernet DWDM infrastructure The data format transmitted by the Ethernet DWDM X2 transceiver on the fiber is identical to that transmitted by the Fibre Channel X2 transceiver exce...

Страница 130: ...ransceiver is encoded with model information that enables the switch to verify that the SFP transceiver meets the requirements for the switch Note Generation 2 modules will not support 1 Gbps 2 Gbps SFPs Generation 2 modules only support 4 Gbps SFPs This section provides the following topics Cisco Fibre Channel SFP and SFP Transceivers page B 10 Cisco Fibre Channel Gigabit Ethernet Transceivers pa...

Страница 131: ...ations for Cisco 8 Gbps Fibre Channel SFP Transceivers SFP Wavelength nanometer Fiber Type Core Size micon Baud Rate GBd Cable Distance meter DS SFP FC8G SW 850 MMF 62 5 2 125 150 m 492 ft 62 5 4 250 70 m 230 ft 62 5 8 500 21 m 69 ft 50 0 OM2 2 125 300 m 984 ft 50 0 OM2 4 250 150 m 492 ft 50 0 OM2 8 500 50 m 164 ft 50 0 OM3 2 125 500 m 1640 ft 50 0 OM3 4 250 380 m 1246 ft 50 0 OM3 8 500 150 m 492 ...

Страница 132: ...9000 Family 2 10 2 Gbps 1 78 4 Gbps 1 58 8 Gbps 2 62 2 Gbps 2 06 4 Gbps 1 68 8 Gbps 3 31 2 Gbps 2 88 4 Gbps 2 04 8 Gbps DS SFP FC8G LW 3 2 Gbps 1 4 Gbps 0 5 8 Gbps 11 7 2 Gbps 8 4 4 Gbps 8 4 8 Gbps 3 2 Gbps 1 4 Gbps 0 5 8 Gbps 7 8 2 Gbps 7 8 4 Gbps 6 4 8 Gbps Table B 18 Power Requirements Specification for Cisco 8 Gbps Fibre Channel SFP Transceivers continued SFP Average Transmit Power dBm Average...

Страница 133: ... Fibre Channel SFP Transceivers SFP Wavelength nanometer Fibre Type Core Size micon Baud Rate GBd Cable Distance meter DS SFP FC4G SW 850 MMF 62 5 1 0625 300 m 984 ft 62 5 2 125 150 m 492 ft 62 5 4 250 70 m 230 ft 50 0 OM2 1 0625 500 m 1640 ft 50 0 OM2 2 125 300 m 984 ft 50 0 OM2 4 250 150 m 492 ft 50 0 OM3 1 0625 860 m 2821 ft 50 0 OM3 2 125 500 m 1640 ft 50 0 OM3 4 250 380 m 1246 ft DS SFP FC4G ...

Страница 134: ...P Transceivers Table B 24 provides the power specification for Cisco 2 Gbps Fibre Channel SFP transceivers Table B 22 Environmental Specifications for Cisco 4 Gbps Fibre Channel SFP Transceivers SFP Operating Storage Maximum Minimum Maximum Minimum DS SFP FC4G SW 40 C 0 C 85 C 40 C DS SFP FC4G MR 40 C 0 C 85 C 40 C DS SFP FC4G LW 40 C 0 C 85 C 40 C Table B 23 General Specifications for Cisco 4 Gbp...

Страница 135: ...combination Fibre Channel Gigabit Ethernet SFP transceivers Table B 25 Environmental Specifications for Cisco 2 Gbps Fibre Channel SFP Transceivers SFP Operating Storage Maximum Minimum Maximum Minimum DS SFP FC 2G SW 40 C 0 C 85 C 40 C DS SFP FC 2G LW 40 C 0 C 85 C 40 C Table B 26 Maximum Environmental and Electrical Ratings for Cisco Fibre Channel SFP Transceivers Parameter1 1 Do not operate out...

Страница 136: ... B 29 provides the power requirement specification for Cisco Fibre Channel Gigabit Ethernet SFP transceivers Table B 28 General Specifications for Cisco Fibre Channel Gigabit Ethernet SFP Transceivers SFP Wavelength nanometer Fibre Type Core Size micon Baud Rate GBd Cable Distance meter DS SFP FCGE SW 850 MMF 62 5 1 0625 300 m 984 ft 62 5 2 125 150 m 492 ft 50 0 OM2 1 0625 500 m 1640 ft 50 0 OM2 2...

Страница 137: ...onmental Specifications for Cisco Fibre Channel Gigabit Ethernet SFP Transceivers SFP Operating Storage Maximum Minimum Maximum Minimum DS SFP FCGE SW 40 C 0 C 85 C 40 C DS SFP FCGE LW 40 C 0 C 85 C 40 C Table B 31 Cisco 1 Gbps and 2 Gbps CWDM SFP Transceivers Description Color Cisco CWDM SFP 1470 nm Gigabit Ethernet and 1 Gbps 2 Gbps FC Gray Cisco CWDM SFP 1490 nm Gigabit Ethernet and 1 Gbps 2 Gb...

Страница 138: ...DM 4 Gbps FC Blue DS CWDM4G1530 Cisco MDS9000 1530 nm CWDM 4 Gbps FC Green DS CWDM4G1550 Cisco MDS9000 1550 nm CWDM 4 Gbps FC Yellow DS CWDM4G1570 Cisco MDS9000 1570 nm CWDM 4 Gbps FC Orange DS CWDM4G1590 Cisco MDS9000 1590 nm CWDM 4 Gbps FC Red DS CWDM4G1610 Cisco MDS9000 1610 nm CWDM 4 Gbps FC Brown Table B 33 Environmental Specifications for Cisco 2 Gbps CWDM SFP Transceivers SFP Operating Stor...

Страница 139: ...ly Environmental and Optical Specifications for Cisco 4 Gbps CWDM SFP Transceivers Table B 35 provides the environmental specifications for the Cisco 4 Gbps CWDM SFP transceivers Receiver Optical Input Power BER 10 12 with PRBS 2 7 1 Pin 29 0 7 0 dBm At 1 25 Gbps 140 F 60 C case temperature Receiver Optical Input Wavelength λin 1450 1620 nm Transmitter Extinction Ratio OMI 9 dB Dispersion Penalty ...

Страница 140: ...bps CWDM SFP transceiver with a Cisco 1 2 Gbps CWDM transceiver the speed of ports on the Cisco 4 Gbps CWDM SFP transceiver must be manually configured to 1 Gbps or 2 Gbps For information about safety regulatory and standards compliance refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family Table B 36 Optical Specification for Cisco 4 Gbps CWDM SFP Transceivers Par...

Страница 141: ...sceiver Environmental and Power Requirement Specifications for Cisco Gigabit Ethernet Transceivers Table B 39 provides the environmental specifications for the Cisco Gigabit Ethernet transceivers For information about safety regulatory and standards compliance refer to the Regulatory Compliance and Safety Information for the Cisco MDS 9000 Family Table B 37 Cisco Gigabit Ethernet SFP Transceivers ...

Страница 142: ...ide scalable easy to deploy DWDM Fibre Channel services in their networks The main features of the Cisco DWDM SFP include Support for International Telecommunication Union ITU 100 GHz wavelength grid Match for wavelength plan of Cisco ONS 100 GHz product family Fixed wavelength SFP with 32 SFP models Note A single Cisco MDS 9000 family switching module supports up to eight 2 Gbps DWDM SFPs For mor...

Страница 143: ...Plugs page C 7 Cables and Adapters Provided The Cisco MDS 9200 Series accessory kit includes the following items RJ 45 rollover cable DB 9F RJ 45F PC RJ 45 to DB 9 female DTE adapter labeled Terminal RJ 45 DSUB F F adapter RJ 45 to DB 25 female DTE adapter labeled Terminal RJ 45 DSUB R P adapter RJ 45 to DB 25 male DCE adapter labeled Modem Note Additional cables and adapters can be ordered from y...

Страница 144: ...DS 9200 Series Connecting the Console Port to a Computer Using the DB 25 Adapter You can use the RJ 45 rollover cable and RJ 45 DSUB F F adapter labeled Terminal to connect the console port to a computer running terminal emulation software Table C 2 lists the pinouts for the console port the RJ 45 rollover cable and the RJ 45 DSUB F F adapter Table C 1 Console Port Pinouts Pin Signal 11 1 Pin 1 is...

Страница 145: ... PC terminal COM1 Port The COM1 port is a serial port with a DB 9 connector The COM1 port can be connected to a modem using the cable and adapters provided in the accessory kit COM1 Port Pinouts Table C 4 lists the pinouts for the COM1 port on the Cisco MDS 9200 Series Note Additional cables and adapters can be ordered from your customer service representative Table C 3 Port Mode Signaling and Pin...

Страница 146: ...lover cable and the RJ 45 DSUB R P adapter MGMT 10 100 1000 Ethernet Port The MGMT 10 100 1000 Ethernet port is an Ethernet port with an RJ 45 connector You can use a modular RJ 45 straight through UTP cable to connect the management port to an external hub switch or router see Figure C 1 Figure C 1 RJ 45 Interface Cable Connector 8 CTS 9 RI Table C 4 COM1 Port Pinouts continued Pin Signal Table C...

Страница 147: ...port MDI cable Note The RJ 45 interface only uses pins 1 2 3 and 6 Figure C 2 shows a schematic of the 10 100 1000BASE T cable required to connect the management port to a switch or hub not provided with the switch Figure C 2 Twisted Pair 10 100 1000BASE T Cable Schematic Table C 6 10 100 1000BASE T Management Port Cable Pinout MDI Pin Signal 1 TD 2 TD 3 RD 6 RD 4 Not used 5 Not used 7 Not used 8 ...

Страница 148: ...45 connector You can use a modular RJ 45 straight through UTP cable to connect the management port to an external hub switch or router see Figure C 3 Figure C 3 RJ 45 Interface Cable Connector Table C 7 lists the connector pinouts and signal names for a 10 100BASE T management port MDI cable Note The RJ 45 interface only uses pins 1 2 3 and 6 1 Pin 1 2 Pin 8 94971 1 2 RJ 45 both ends Table C 7 10 ...

Страница 149: ...ative to the standard power cords Power Cords The standard power cords have an IEC C19 connector on the end that plugs into the switch The optional jumper power cords have an IEC C19 connector on the end that plugs into the switch and an IEC C20 connector on the end that plugs into an IEC C19 outlet receptacle Note Only the regular power cords or jumper power cords provided with the switch are sup...

Страница 150: ... power supplies Power Cord 250 VAC 10 A CEI 23 16 VII Plug Italy 8 2 2 5 Power Cord 250 VAC 10 A BS1363 Plug 13 A fuse UK 8 2 2 5 Power Cord 250 VAC 10 A IRAM 2073 Plug Argentina 8 2 2 5 Power Cord 250 VAC 10 A MP232 Plug Switzerland 8 2 2 5 Power Cord 250 VAC 10 A SABS 164 1 Plug South Africa 6 1 83 Power Cord 250 VAC 10 A SI32 Plug Israel 14 76 4 5 Power Cord 250 VAC 15 A CNS10917 2 Plug Taiwan ...

Страница 151: ...C power supply only Figure C 6 Additional Power Supply Plug Supported for 1900 W Only 1 International 6000 W 3000 W 2500 W and 1900 W IEC 309 20 A 4 North America locking 6000 W 3000 W 2500 W and 1900 W NEMA L6 20 plug 2 0A 2 Europe 6000 W 3000 W 2500 W and 1900 W CEE 7 7 16 A 5 Switzerland 6000 W 3000 W 2500 W and 1900 W 23 G SEV 1011 16 A 3 North America non locking 6000 W 3000 W 2500 W and 1900...

Страница 152: ...7 at 110 VAC results in 1300 W available to the system Figure C 7 Additional Power Supply Plug Supported for 3000 W and 2500 W 110 VAC Only Supported Plugs for the 4000 W AC Power Supply Figure C 8 shows the supported plugs for the 4000 W AC power supply The power cable on the 4000 W power supply is nondetachable Figure C 8 4000 W Power Supply Plugs 1 NEMA 5 20P North American power cord product I...

Страница 153: ...ctors on the optional jumper power cord for the Cisco MDS 9200 Series The C19 connector plugs into the C20 inlet on the Cisco MDS 9200 Series power supply while the C20 connector plugs into the C19 receptacle of a power distribution unit for a cabinet Figure C 9 End of C19 and C20 Connectors on Jumper Power Cord for Cisco MDS 9200 Series 1 C19 and C20 connectors on jumper power cord for Cisco 9200...

Страница 154: ... m e n t a t i o n c o m m e n t s t o m d s f e e d b a ck d o c c i s c o c o m C 12 Cisco MDS 9200 Series Hardware Installation Guide OL 19588 01 Appendix C Cable and Port Specifications MGMT 10 100 Ethernet Port ...

Страница 155: ...itch for configuration information see the Cisco MDS 9000 Family NX OS Interfaces Configuration Guide or the Cisco Fabric Manager Interfaces Configuration Guide Site Preparation Checklist Planning the location and layout of your equipment rack or wiring closet is essential for successful switch operation ventilation and accessibility Table D 1 lists the site planning tasks that we recommend comple...

Страница 156: ...e Humidity Altitude Atmospheric contamination Air flow 3 Power evaluation Input power type Power receptacles1 Receptacle proximity to the equipment Dedicated circuit for power supply Dedicated separate circuits for redundant power supplies UPS2 for power failures 1 Verify that the power supply installed in the chassis has a dedicated AC source circuit 2 UPS uninterruptible power supply 4 Grounding...

Страница 157: ...cords Contact and Site Information Contact and Site Information Use the following worksheet Table D 2 to record contact and site information 3 EMI electromagnetic interference 4 RFI radio frequency interference Table D 2 Contact and Site Information Contact person Contact phone Contact e mail Building site name Data center location Floor location Address line 1 Address line 2 City State Zip code C...

Страница 158: ...out the chassis and modules Contract Number_______________________________________________ Chassis Serial Number___________________________________________ Product Number________________________________________________ Note The supervisor module and the interface module are not removable Table D 3 Network Related Information Switch IP address Switch IP netmask Host name Domain name IP broadcast ad...

Страница 159: ...ule See SSM 32 port switching modules description 1 16 figure 1 17 LEDs table 1 16 1 19 4 1 12 4 44 port 8 Gbps Host Optimized Fibre Channel Switching Module 1 12 4 44 Port 8 Gbps Host Optimized Fibre Channel switching modules description 1 12 4 44 port 8 Gbps Host Optimized Fibre Channel switching modules connectors 1 12 figure 1 12 48 port 4 Gbps Fibre Channel switching modules connectors 1 12 d...

Страница 160: ...OM1 port cabling C 3 connecting figure 3 4 connecting procedure 3 4 pinouts table C 3 connecting console port figure 3 2 console port procedure 3 2 Fibre Channel ports 3 6 MGMT 10 100 3 5 console port cabling C 2 connecting figure 3 2 connecting procedure 3 3 pinouts C 2 contact and site information records D 3 worksheet D 3 CSM batteries 2 35 battery specifications table B 3 description 1 31 figu...

Страница 161: ...t 2 23 H heat dissipation specifications B 5 I installing equipment required 2 4 rack mount front facing 2 6 rack mount rear facing 2 16 rack mount rotated brackets 2 14 rack mount front facing figure 2 9 rack mount rear facing figure 2 17 SFP transceiver cables 3 11 SFP transceivers note 3 10 X2 transceivers 3 8 interface module description 1 9 figure 1 9 LEDs table 1 10 IPS modules description 1...

Страница 162: ...rnet port C 4 MGMT 10 100 Ethernet port C 6 plugs supported for power supplies C 7 ports COM1 3 4 console 3 2 Fibre Channel 3 6 MGMT 10 100 3 5 power cord jumper C 11 power cords length C 7 power on front panel LEDs 1 28 power supplies description 1 35 figure 1 35 installing procedure 2 36 LED table 1 35 removing procedure 2 36 specifications B 4 supported plugs C 7 Preface i xiii pre installation...

Страница 163: ...intaining fiber optic cables procedures 3 13 removing 3 10 removing a cable procedure 3 12 specifications B 10 supported 1 36 shelf bracket installation four post EIA rack A 7 installation Telco IEA A 6 installing switch A 8 removing kit A 9 Telco EIA kit note A 4 site planning preparation checklist D 1 software release requirement 1 2 specifications airflow B 2 cables C 1 environmental B 1 heat d...

Страница 164: ... image 1 28 features 1 18 installing procedure 2 33 LEDs table 1 16 1 19 positioning in chassis figure 2 30 power and heat specification B 5 removing 2 31 2 32 removing procedure 2 32 specifications B 2 verifying installation 2 34 switch specifications table B 1 system grounding 2 19 T T 1 12 Table B 1 Telco racks requirements A 4 transceivers supported SFPs See SFP transceivers W weight of module...