S e n d d o c u m e n t a t i o n c o m m e n t s t o m d s f e e d b a c k - d o c @ c i s c o . c o m
B-18
Cisco MDS 9200 Series Hardware Installation Guide
OL-19588-01
Appendix B Technical Specifications
SFP and SFP+ Transceiver Specifications
Table B-32
lists the Cisco 4-Gbps CWDM SFP transceivers available through Cisco.
Environmental and Optical Specifications for Cisco 2-Gbps CWDM SFP Transceivers
Table B-33
provides the environmental specifications for the Cisco 2-Gbps CWDM SFP transceivers.
Table B-34
provides the optical specifications for the Cisco 2-Gbps CWDM SFP transceivers.
Table B-32
Cisco 4-Gbps CWDM SFP Transceivers
Description
Color
DS-CWDM4G1470: Cisco MDS9000 1470 nm; CWDM 4-Gbps FC
Gray
DS-CWDM4G1490: Cisco MDS9000 1490 nm; CWDM 4-Gbps FC
Violet
DS-CWDM4G1510: Cisco MDS9000 1510 nm; CWDM 4-Gbps FC
Blue
DS-CWDM4G1530: Cisco MDS9000 1530 nm; CWDM 4-Gbps FC
Green
DS-CWDM4G1550: Cisco MDS9000 1550 nm; CWDM 4-Gbps FC
Yellow
DS-CWDM4G1570: Cisco MDS9000 1570 nm; CWDM 4-Gbps FC
Orange
DS-CWDM4G1590: Cisco MDS9000 1590 nm; CWDM 4-Gbps FC
Red
DS-CWDM4G1610: Cisco MDS9000 1610 nm; CWDM 4-Gbps FC
Brown
Table B-33
Environmental Specifications for Cisco 2-Gbps CWDM SFP Transceivers
SFP
Operating
Storage
Maximum
Minimum
Maximum
Minimum
All Cisco 2-Gbps
CWDM SFP
Transceivers
40°C
0°C
85°C
-40°C
Table B-34
Optical Specification for Cisco 2-Gbps CWDM SFP Transceivers
Parameters Symbol
Minimum
Typical
Maximum
Units
Notes/Conditions
Transmitter Center
Wavelength
λ
c
x-4
–
x+7
nm
Available center
wavelengths are
1470, 1490,
1510, 1530,
1550, 1570,
1590, and 1610
nm
Side-mode
Suppression Ratio
SMSR
30
–
–
dB
–
Transmitter Optical
Output Power
P
out
0.0
5.0
dBm
Average power
coupled into
single-mode fiber
Receiver Optical
Input Power (BER
<10-12 with PRBS
2-7-1)
P
in
-28.0
–
-7.0
dBm
At 2.12 Gbps,
140°F (60°C)
case temperature