background image

Cisco MDS 9148T 32-Gbps 48-Port Fibre Channel Switch Hardware
Installation Guide

First Published:

2018-04-10

Last Modified:

2018-04-11

Americas Headquarters

Cisco Systems, Inc.
170 West Tasman Drive
San Jose, CA 95134-1706
USA
http://www.cisco.com
Tel: 408 526-4000

800 553-NETS (6387)

Fax: 408 527-0883

Содержание MDS 9148T

Страница 1: ... Switch Hardware Installation Guide First Published 2018 04 10 Last Modified 2018 04 11 Americas Headquarters Cisco Systems Inc 170 West Tasman Drive San Jose CA 95134 1706 USA http www cisco com Tel 408 526 4000 800 553 NETS 6387 Fax 408 527 0883 ...

Страница 2: ...e encouraged to try to correct the interference by using one or more of the following measures Reorient or relocate the receiving antenna Increase the separation between the equipment and receiver Connect the equipment into an outlet on a circuit different from that to which the receiver is connected Consult the dealer or an experienced radio TV technician for help Modifications to this product no...

Страница 3: ...k Installation 15 C H A P T E R 3 Cabinet and Rack Requirements 15 General Requirements for Cabinets and Racks 15 Requirements Specific to Perforated Cabinets 16 Reference Perforated Cabinet 16 Requirements Specific to Solid Walled Cabinets 16 Installing the Cisco MDS 9148T Switch 19 C H A P T E R 4 Preinstallation 19 Cisco MDS 9000 Series Telco and EIA Shelf Bracket 19 Shelf Installation Guidelin...

Страница 4: ...dules 37 Installing a Fan Module 38 Removing a Fan Module 38 Connecting the Cisco MDS 9148T Switch 41 C H A P T E R 5 Preparing for Network Connections 41 Connecting the Console Port 42 Connecting the Console Port to a PC 42 Connecting a Modem to a Console Port 43 43 Connecting the Management Ports 44 Connecting to a Fibre Channel Port 44 Removing and Installing Cables into SFP Transceivers 44 Ins...

Страница 5: ...g the Console Port to a Computer Using the DB 25 Adapter 56 Connecting the Console Port to a Computer Using the DB 9 Adapter 57 Out of Band Ethernet Management Port 57 Supported Power Cords and Plugs 59 Standard Power Cords 60 Jumper Power Cord 60 Fibre Cable Specifications 60 Site Planning and Maintenance Records 61 A P P E N D I X B Site Preparation Checklist 61 Contact and Site Information 63 C...

Страница 6: ...Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide vi Contents ...

Страница 7: ...sco MDS 9000 Series Configuration Guides It also provides information on how to obtain related documentation and contains the following chapters Audience To use this installation guide you need to be familiar with electronic circuitry and wiring practices and preferably be an electronic or electromechanical technician Document Conventions This document uses the following conventions Means reader t...

Страница 8: ...roducts device support tables list html Installation and Upgrade http www cisco com c en us support storage networking mds 9000 nx os san os software products installation guides list html Configuration http www cisco com c en us support storage networking mds 9000 nx os san os software products installation and configuration guides list html CLI http www cisco com c en us support storage networki...

Страница 9: ...your desktop you can subscribe to the What s New in Cisco Product Documentation RSS feed RSS feeds are a free service Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 3 Preface Obtaining Documentation and Submitting a Service Request ...

Страница 10: ...Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 4 Preface Obtaining Documentation and Submitting a Service Request ...

Страница 11: ...Slow Drain Detection and Isolation Virtual SAN VSAN and Inter VSAN routing IVR and migration from fabricwide Quality of Service QoS from SAN islands to enterprisewide storage networks Provides intelligent diagnostics tools such as Inter Switch Link ISL diagnostics HBA diagnostics with leading HBA vendors read diagnostic parameters protocol decoding network analysis tools and integrated Cisco Call ...

Страница 12: ...gement ports 2 8 System status LED 2 Fixed FC ports 9 Power status LED 3 FC port status LEDs 48 10 Fan status LED 4 Airflow grill 11 USB port 5 Link status LED 6 Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 6 Overview of Cisco MDS 9148T Fibre Channel Switch Switch Overview ...

Страница 13: ...s 7 Power supply unit fan 2 Chassis fan modules 4 units 8 Power supply unit handle 3 Chassis fan module release latches 8 9 Unswitched power receptacle 4 Power supply unit latch release 5 Side View The following figure shows the side view of a Cisco MDS 9148T Switch Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 7 Overview of Cisco MDS 9148T Fibre Channel Switch S...

Страница 14: ...s redundancy for uninterrupted operation in the event of fan module failure The Cisco MDS 9148T Switch fan modules are hot swappable to also allow swapping out of a fan module during operation for uninterrupted operation During a fan module replacement the internal airflow through the chassis is changed If the internal airflow is disrupted for too long the preset temperature thresholds will be exc...

Страница 15: ...chassis The Cisco MDS 9148T Switch requires a minimum of one operating PSU It supports up to two PSUs This provides redundancy for uninterrupted operation in the event of PSU or grid failure The PSUs are hot swappable to allow swapping out of a PSU during operation for uninterrupted operation During a PSU replacement the internal airflow through the chassis is changed If the internal airflow is di...

Страница 16: ...ck of the switch to indicate the status of different system components during bootup tests and online operation The following tables describe the location of each LED and the meaning of its color Table 1 Chassis Activity LEDs for a Cisco MDS 9148T Switch State Status Color Function Location Indicator Either of the following conditions exists The system is not receiving sufficient power from the PS...

Страница 17: ...e following modules Fan modules The switch will go down in 10 15 seconds PSUs The switch will go down after 10 minutes Fan modules and PSUs The switch will go down after 10 minutes Blinking Red One of the following conditions exists A diagnostic test failed or another fault occurred during bootup A major temperature threshold is exceeded Solid On All fan modules are operational Solid on Green Fan ...

Страница 18: ...tatus The fan in the fan module has failed Solid on Amber The following table describes the Ethernet port LEDs for a Cisco MDS 9148T switch State Status LED Position There is no link Off Left Indicates a physical link Solid Green There is no link traffic Off Right Indicates link traffic Blinking Yellow The following table describes the Fibre Channel port LEDs for a Cisco MDS 9148T switch State Sta...

Страница 19: ...isabled by the software Solid Orange A fault condition exists Blinking Orange No link Off Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 13 Overview of Cisco MDS 9148T Fibre Channel Switch LEDs ...

Страница 20: ...Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 14 Overview of Cisco MDS 9148T Fibre Channel Switch LEDs ...

Страница 21: ...osts that conform to English universal hole spacing per section 1 of ANSI EIA 310 D 1992 See Requirements Specific to Perforated Cabinets and Requirements Specific to Solid Walled Cabinets Standard two post telco rack with mounting posts that conform to English universal hole spacing per section 1 of ANSI EIA 310 D 1992 The cabinet or rack must also meet the following requirements The minimum vert...

Страница 22: ...Requirements for Cabinets and Racks on page 15 section perforated cabinets with front to back airflow must meet the following requirements The front and rear doors must have at least a 60 percent open area perforation pattern with at least 15 sq in 96 7 sq cm of open area per rack unit of door height We recommend that the roof be perforated with at least 20 percent open area unless the cabinet onl...

Страница 23: ...ly from bottom to top The overall cabinet depth to be 36 to 42 in 91 4 to 106 7 cm to allow the doors to close and to facilitate adequate airflow A minimum of 150 sq in 968 sq cm of open area to be available at the floor air intake of the cabinet The lowest piece of equipment to be installed at a minimum of 1 RU 1 75 in or 4 4 cm above the floor openings to prevent blockage of the floor intake Cis...

Страница 24: ...Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 18 Cabinet and Rack Installation Requirements Specific to Solid Walled Cabinets ...

Страница 25: ...replace or service this equipment Statement 1030 Warning Preinstallation on page 19 Installing the Switch on page 26 Grounding the Switch on page 33 Installing and Removing Components on page 34 Preinstallation Cisco MDS 9000 Series Telco and EIA Shelf Bracket The optional Telco and EIA Shelf Bracket Kit part number DS SHELF can temporarily or permanently support the Cisco MDS 9148T switch during ...

Страница 26: ...e Shelf Brackets Before installing the shelf brackets inspect the contents of your kit The following table lists the contents of the shelf bracket kit Part Description Quantity Slider brackets 2 Shelf brackets 2 Crossbar 1 10 32 x 3 8 in Phillips pan head screws 2 12 24 x 3 4 in Phillips screws 16 10 24 x 3 4 in Phillips screws 16 Required Equipment You need the following equipment for this instal...

Страница 27: ...d align with the bottom hole the hole immediately above the 1 2 in spacing of a rack unit on the rack mounting post Note Step 2 Repeat Step 1 with the other shelf brackets Step 3 Verify that the shelf brackets are at the same height using the level or tape measure as desired Step 4 Attach the crossbar to the rear of the shelf brackets as shown in Figure 6 Installing the Shelf Bracket Kit into a Te...

Страница 28: ...ttom hole the hole immediately above the 1 2 in spacing of a rack unit on the rack mounting post Note Step 2 Repeat Step 1 with the other shelf brackets Step 3 Verify that the shelf brackets are at the same height using the level or tape measure as desired Step 4 Attach the crossbar to the shelf brackets as shown in Figure 7 Installing the Shelf Bracket Kit into an EIA Rack on page 22 using the 10...

Страница 29: ...delines when installing the Cisco MDS 9148T switch Each new switch requires a license See the Cisco MDS 9000 Family NX OS Licensing Guide for instructions on installing a license Plan your site configuration and prepare the site before installing the switch Ensure that there is adequate space around the switch to allow for servicing the switch and for adequate airflow The airflow requirements are ...

Страница 30: ...e shipping container in case the chassis has to be shipped in the future Tip The switch is thoroughly inspected before shipment If any damage occurs during transportation or if any item is missing contact your customer representative immediately If you purchased Cisco support through a Cisco reseller contact the reseller directly If you purchased support directly from Cisco contact Cisco Technical...

Страница 31: ...e In case of port side intake airflow the chassis is not Network Equipment Building System NEBS compliant by default To be NEBS compliant install the NEBS kit by performing these steps 1 Install the NEBS rack mount brackets onto the switch 2 Install the NEBS air baffle by aligning the notches on the baffle with the slots on the brackets and sliding the ends of the baffle so that the baffle locks i...

Страница 32: ...ction Installing the Switch in a 4 Post Rack To install the switch you must attach the front and rear mounting guides to the switch install the slider rails on the rear of the rack slide the switch into the slider rails and secure the switch to the front of the rack Typically the front of the rack is the side that is easiest to access for maintenance Before you begin Inspect the switch shipment to...

Страница 33: ...ides better clearance for maneuvering the chassis in and out during installation and servicing The end that needs to enter the rack first requires the guides and the other end the brackets Step 1 Install two rack mount brackets to the switch as follows 1 Position a rack mount bracket so that four of its screw holes are aligned to the screw holes on the side of the chassis You can align any four of...

Страница 34: ... the middle two screw holes in the remaining six screw holes on a side of the chassis 2 Attach the guide to the chassis using two M4 screws Tighten the screws to 12 in lb 1 36 N m of torque 3 Repeat Step 2 for the other rack mount guide on the other side of the switch Step 3 If you are installing the chassis into an ungrounded rack you must attach a customer supplied grounding wire to the chassis ...

Страница 35: ...n the vertical mounting posts Step 5 Insert the switch into the rack and attach it as follows Direction of insertion 3 Fan tray end of the chassis 1 Slider rails 4 rack mount screws 2 1 Holding the switch with both hands position the two rack mount guides on the switch between the rack or cabinet posts that do not have slider rails attached to them 2 Align the two rack mount guides on either side ...

Страница 36: ...ine which way the chassis should slide in and out of the rack port side entry first or rear side entry first You might consider whether the front or back of the rack provides better clearance for maneuvering the chassis in and out during installation and servicing The end that needs to enter the rack first requires the guides and the other end the brackets Step 1 Install two rack mount brackets on...

Страница 37: ...ing the switch with both hands position the back of the switch between the two posts of the rack Then gently move the switch until the rack mount brackets come in contact with two rack posts 2 Holding the chassis level insert three screws 12 24 or 10 32 depending on the rack type into each of the two rack mount brackets using a total of six screws and into the cage nuts or threaded holes in the ra...

Страница 38: ...tch onto the 2 Post Rack From the Rear Side of the Chassis 3 Tighten the 10 32 screws to 20 in lb 2 26 N m or tighten the 12 24 screws to 30 in lb 3 39 N m Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 32 Installing the Cisco MDS 9148T Switch Installing the Switch into a 2 Post Rack ...

Страница 39: ...rtain that suitable grounding is available Statement 1024 Warning When installing or replacing the unit the ground connection must always be made first and disconnected last Statement 1046 Warning Step 1 Use a wire stripping tool to remove approximately 0 75 in 1 9 cm of the covering from the end of the grounding wire Step 2 Insert the stripped end of the grounding wire into the open end of the gr...

Страница 40: ...em is operating Use caution when servicing Statement 1034 Warning During this procedure wear grounding wrist straps to avoid ESD damage to the switch Caution Installing the ESD Grounding Strap This section illustrates how to prepare yourself before removing the chassis from the sealed antistatic bag The figures show how to cuff the ESD strap around the wrist and the ground cord that connects the c...

Страница 41: ...oses The chassis actual appearance and size may vary Figure 15 Wearing the ESD Strap Note Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 35 Installing the Cisco MDS 9148T Switch Installing the ESD Grounding Strap ...

Страница 42: ... Supply Units You can replace one power supply unit PSU while the other one provides power to the switch Before you begin To implement n n redundancy each PSU must be connected to a separate power feed Otherwise only one power feed is required Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 36 Installing the Cisco MDS 9148T Switch Installing and Removing Power Supp...

Страница 43: ...ct the switch to your outlet receptacle Note Step 5 Verify that the PSU is operational by making sure that the PSU LEDs are both green For information on what the PSU LEDs indicate see the LEDs section Removing Power Supply Units You can remove one faulty PSU while the other one provides enough power to operate the switch Step 1 Holding the plug for the power cable pull the plug out from the power...

Страница 44: ... by its handle align the back of the fan module the side with the electrical connectors to the open fan slot in the chassis Step 2 Slide the fan module into the fan module bay until it clicks into place Step 3 Verify that the Status LED turns on and becomes green For more information on what the LEDs indicate see the LEDs Removing a Fan Module The fan module is designed to be removed and replaced ...

Страница 45: ...les enough to unseat it from its connectors Step 2 Holding the handle pull the module out of the chassis Do not touch the electrical connectors on the back side of the module and prevent anything else from coming into contact with and damaging the connectors Caution Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 39 Installing the Cisco MDS 9148T Switch Removing a ...

Страница 46: ...Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 40 Installing the Cisco MDS 9148T Switch Removing a Fan Module ...

Страница 47: ... backups and capturing logs to file This chapter describes how to connect the various components of the Cisco MDS 9148T switch Preparing for Network Connections on page 41 Connecting the Console Port on page 42 Connecting the Management Ports on page 44 Connecting to a Fibre Channel Port on page 44 Powering Up the Switch on page 47 Preparing for Network Connections When preparing your site for net...

Страница 48: ... application such as HyperTerminal Plus makes the communication between the Cisco MDS 9148T switch and your PC possible during setup and configuration Note To connect the console port to a PC follow these steps Step 1 Configure the baud rate and character format of the PC terminal emulation program to match the following management port default characteristics 9600 baud 8 data bits 1 stop bit No p...

Страница 49: ...ult console port characteristics are applied to the modem connection 9600 baud 8 data bits 1 stop bit No parity Default initialization string ATE0Q1 D2 C1S0 1 015 if previously configured For instructions on how to change these settings see the Cisco Fabric Manager Fundamentals Configuration Guide Note To connect the console port to a modem after the switch is powered on follow these steps Step 1 ...

Страница 50: ...the Cisco NX OS Fundamentals Configuration Guide Each transceiver must match the transceiver at the other end of the cable and the cable must not exceed the stipulated cable length for reliable communications SFP transceivers can be ordered either separately or with the Cisco MDS 9148T switch Class 1 laser product Statement 1008 Warning Invisible laser radiation may be emitted from disconnected fi...

Страница 51: ...s keys to allow insertion only one way into the transceiver If the cable does not install easily ensure that it is correctly oriented before continuing Caution For instructions on verifying connectivity see the Cisco Fabric Manager Fundamentals Configuration Guide and the Cisco NX OS Fundamentals Configuration Guide Removing a Cable from an SFP Transceiver When pulling a cable from a transceiver g...

Страница 52: ...rements for the switch Note The Cisco MDS 9148T switch supports transceivers with the following types of latching devices Mylar tab latch Bale clasp latch Installing an SFP Transceiver To install an SFP transceiver follow these steps Step 1 Attach an ESD preventive wrist strap and follow its instructions for use Step 2 Remove the dust plug from the FC port Step 3 Insert the transceiver into the po...

Страница 53: ...ESD damage wear an ESD preventive wrist strap that is connected to the chassis while handling transceivers Do not remove and reinsert a transceiver more often than necessary Repeated removals and insertions can shorten its useful life Keep all optical connections covered when not in use If they become dusty clean them before using in order to prevent dust from scratching the fiber optic cable ends...

Страница 54: ... Step 9 Verify that the LED behavior is as follows when the switch has finished booting Fan status LED is green Both LEDs on each PSU are green The switch status LED is green If this LED is orange or red it indicates that one or more environmental monitors is reporting a problem The Ethernet port link LEDs should not be On unless the cable is connected The LEDs for the Fibre Channel ports remain o...

Страница 55: ...ic configuration For instructions about how to configure the switch and check module connectivity see the Cisco Fabric Manager Fundamentals Configuration Guide Note Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 49 Connecting the Cisco MDS 9148T Switch Powering Up the Switch ...

Страница 56: ...Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 50 Connecting the Cisco MDS 9148T Switch Powering Up the Switch ...

Страница 57: ...ting and storage 10 to 90 Humidity RH ambient noncondensing operating 10 to 95 Humidity RH ambient noncondensing nonoperating and storage 197 to 6500 ft 60 to 2000 m Altitude operating The following table lists the physical specifications for the Cisco MDS 9148T switch Table 3 Physical Specifications for the Cisco MDS 9148T Switch Specification Description 1 72 x 17 3 x 22 3 in 4 37 x 43 94 x 56 6...

Страница 58: ...air space of 2 5 in 6 4 cm between walls and chassis air vents and a minimum horizontal separation of 6 in 15 2 cm between two chassis to prevent overheating Airflow Power Specifications General Power Supply Specifications The following table lists the specifications for the Cisco MDS 9148T switch AC power supply Table 4 Power Supply Specifications Specification AC Input Power 100 to 240 VAC AC in...

Страница 59: ... 110V 60HZ Watts Fan Trays Optics Number Optics Speed Voltage Temperature Traffic Rate PSU Power Mode 251 257 4 24 32G SW Nominal 25 C 50 2 Typical 297 305 48 260 267 4 24 32G SW Nominal 25 C 100 2 Max 315 323 48 32G LW 315 322 32G SW 40 C 348 374 32G LW 55 C 385 403 Nominal 5 Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 53 Technical Specifications Power Supply ...

Страница 60: ...Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 54 Technical Specifications Power Supply Requirement Specifications ...

Страница 61: ...Adapters on page 55 Console Port on page 56 Out of Band Ethernet Management Port on page 57 Supported Power Cords and Plugs on page 59 Cables and Adapters The Cisco MDS 9148T Switch accessory kit includes the following RJ 45 to RJ 45 rollover cable RJ 45 to DB 9 female DTE adapter labeled Terminal RJ 45 to DB 25 female DTE adapter labeled Terminal RJ 45 to DB 25 male DCE adapter labeled Modem Addi...

Страница 62: ...nally to pin 8 Connecting the Console Port to a Computer Using the DB 25 Adapter You can use the RJ 45 to RJ 45 rollover cable and the RJ 45 to DB 25 female DTE adapter labeled Terminal to connect the console port to a computer running terminal emulation software The following table lists the pinouts for the console port the RJ 45 to RJ 45 rollover cable and the RJ 45 to DB 25 female DTE adapter T...

Страница 63: ...cable and the RJ 45 to DB 9 female DTE adapter Table 8 Port Mode Signaling and Pinouts with DB 9 Adapter Console Device RJ 45 to DB 9 Terminal Adapter RJ 45 to RJ 45 Rollover Cable Console Port Signal DB 9 Pin RJ 45 Pin RJ 45 Pin Signal CTS 8 8 1 RTS DSR 6 7 2 DTR RxD 2 6 3 TxD GND 5 5 4 GND GND 5 4 5 GND TxD 3 3 6 RxD DTR 4 2 7 DSR RTS 7 1 8 CTS Out of Band Ethernet Management Port Use a modular ...

Страница 64: ... 1 BI DA 2 BI DB 3 BI DC 4 BI DC 5 BI DB 6 BI DD 7 BI DD 8 The following figure shows a schematic representation of the 10 100 1000 BASE T cable Figure 19 Twisted Pair 10 100 1000 BASE T Cable The following table lists the connector pinouts and signal names for a 10 100 BASE T management port MDI cable Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 58 Cable and Po...

Страница 65: ...rds may be ordered with the product There are two types standard power cords with a country specific plug for use with wall outlets and jumper power cords for use with cabinet outlets The user may also source their own power cords for the product as long as they meet the power cord specifications for this product Only the standard power cords or jumper power cords ordered from Cisco are supported ...

Страница 66: ...er cords see the Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Data Sheet Jumper Power Cord Jumper power cords have an IEC C15 connector on the outlet end of the cord and an IEC C14 connector on the inlet end of the cord This cord is compatible with IEC C13 outlet receptacles This type of outlet receptacle is commonly used for power distribution inside cabinets To see the list of supported ...

Страница 67: ...Preparation Checklist Planning the location and layout of your equipment rack or wiring closet is essential for successful switch operation ventilation and accessibility The following table lists the site planning tasks we recommend that you complete before installing the Cisco MDS 9148T Switch Consider heat dissipation when sizing the air conditioning requirements for an installation Table 11 Sit...

Страница 68: ...or power supply Dedicated separate circuits for redundant power supplies UPS2 for power failures 3 Grounding evaluation Circuit breaker size CO ground AC powered systems 4 Cable and interface equipment evaluation Cable type Connector type Cable distance limitations Interface equipment transceivers 5 Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 62 Site Planning a...

Страница 69: ...te Information Use the following worksheet to record contact and site information Table 12 Contact and Site Information Contact person Contact phone Contact E Mail Building site name Data center location Floor location Address line 1 Address line 2 City State Zip code Country Chassis and Network Information Use the following worksheet to record chassis and network information Cisco MDS 9148T 32 Gb...

Страница 70: ...tch IP netmask Host name Domain name IP broadcast address Gateway router address DNS address Modem telephone number Cisco MDS 9148T 32 Gbps 48 Port Fibre Channel Switch Hardware Installation Guide 64 Site Planning and Maintenance Records Site Planning and Maintenance Records ...

Отзывы: