18
Product Documentation and Compliance for the Cisco IE 5000 Switches—
Documentation produit et conformité pour les commutateurs Cisco IE 5000
78-100604-01
Note
If you have a low-voltage DC power-supply module, connect the wires to the terminals labeled
Lo
. If
you have a high-voltage DC power-supply module, connect the wires to the terminals labeled
Hi
.
Step 7
To connect the AC power:
a.
Connect the line wire into the terminal screw labeled
L
and the neutral wire into the terminal
screw labeled
N
.
b.
Make sure that you cannot see any wire lead. Only wire
with
insulation
should extend from the
terminal screw.
Figure 1-17
Connecting the Wires to the High-Voltage AC Power (PSU1)
To connect the DC power:
a.
Connect the positive wire into the terminal screw labeled
+
, and the negative wire into the
terminal screw labeled
–
.
b.
Make sure that you cannot see any wire lead. Only wire
with
insulation
should extend from the
terminal screw.
Figure 1-18
Connecting the Wires to the Low-Voltage DC Power (PSU2)
100-240V~, 50-60H
z, 2.2A
100-240V~, 50-60H
z, 2.2A