![Cisco Firepower 1600 Скачать руководство пользователя страница 50](http://html.mh-extra.com/html/cisco/firepower-1600/firepower-1600_getting-started-manual_64696050.webp)
• Serial Connection/Laptop—You can use the RJ-45 to DP-9 console cable supplied with the appliance
(Cisco part number 72-3383-XX) to connect a computer to the appliance. Refer to the figure at
to identify the serial port. To interact with the appliance, use terminal
emulation software such as HyperTerminal or XModem.
• Lights-Out Management Using Serial over LAN—You can perform a limited set of actions on
FMCs using LOM with an SOL connection. If you do not have physical access to an appliance, you
can use LOM to perform the restore process. After you connect to an appliance using LOM, you
issue commands to the restore utility as if you were using a physical serial connection.
You can use LOM on the default (eth0) management interface only (see the
diagram at
Rear Panel Features, on page 1
). To restore an FMC using LOM,
you must grant LOM permission to the
admin
user. For more information, see
Set Up Lights-Out Management, on page 40
.
Note
When restoring a device to factory settings using LOM, if you do not have physical
access to the appliance you will be unable to access the appliance after the restore.
Caution
The procedures in this chapter explain how to restore an appliance without powering it down. However, if
you need to power down for any reason, use the appliance’s web interface, the
system shutdown
command
from the FMC CLI or the
shutdown -h now
command from the appliance shell.
Note
Restore a Firepower Management Center to its Factory Defaults
This topic provides a high-level description of the tasks required to restore a FMC to factory defaults, and the
order in which you must perform them.
Before you begin
Become familiar with the FMC's interactive restore menu. For more information, see
Procedure
Step 1
Obtain the restore and ISO update files. See
Obtain the Restore ISO and Update Files, on page 52
.
Step 2
Start the restore process using one of these two methods:
•
Start the Restore Utility Using KVM or Physical Serial Port, on page 53
•
Start the Restore Utility Using Lights-Out Management, on page 53
(This is useful if you do not have
physical access to the appliance.)
Cisco Firepower Management Center 1600, 2600, and 4600 Getting Started Guide
50
Cisco Firepower Management Center 1600, 2600, and 4600 Getting Started Guide
Restore a Firepower Management Center to its Factory Defaults