2-13
Cisco Physical Security Multiservices Platform Series User Guide
OL-21838-03
Chapter 2 Setting Up and Maintaining the Multiservices Platform Series Device
Multiservices Platform Series Maintenance Operations
Figure 2-8
Installing a Rear Fan
Procedure
Step 1
Remove the chassis cover as described in the
“Removing the Chassis Cover” section on page 2-11
Step 2
To remove a fan, press and hold the release tab at the top of the fan and pull the fan straight up.
Step 3
To install a fan, slide the fan into a fan slot until it locks into place.
The fan fits in only one way.
Step 4
Replace the chassis cover.
Replacing a Power Supply
The Multiservices Platform Series 2-RU model supports a second power supply for redundancy, which
allow the devices to continue to operate if one power supplies fails. If a power supply does fail, you
should replace it as soon as possible. Power supplies are hot swappable, which allows you to replace one
power supply at a time while the Multiservices Platform Series device is powered on.
Note
When you replace a power supply, make sure to replace it with the same model. The Cisco part number
for the power supply is CIVS-PS-900=.