Four Power
Supplies
Three Power
Supplies
Two Power
Supplies
One Power Supply
Input voltage
4020W
3030W
2040W
1050W
110V
7820W
5880W
3940W
2000W
220V
Redundant (N+1) Mode
In a redundant configuration, a given power supply module can either be active, or in standby mode. In N+1
redundant mode, N is the number of active power supply modules and +1 is the power supply module configured
as the standby module.
You can configure redundancy mode in the software. When the switch is configured with N+1 redundancy,
software ensures that there is a standby power supply available and there is sufficient power available with
the active power supply modules (N). All the power supplies including active and standby will share the load
equally. . However, with a standby power supply installed, system ensures that the additional output power
available with a standby is always reserved for use in case of a failure. If the power supply mode is set to
redundant mode and the total active output power is not sufficient to meet the power requirements, the switch
will not enter the redundant mode.
You can use a combination of AC and DC power supplies provided the AC input voltage is 220V and the
power supplies must be of equal wattage. However, you cannot combine two AC power supplies of 110V
input and 220V input.
The following table provides details about the power output in N+1 redundant mode:
Four Power Supplies
Three Power Supplies
Two Power Supplies
Input voltage
3030W
2040W
1050W
110V
5880W
3940W
2000W
220V
For detailed software configuration information, see the required version of the
Software Configuration Guide
.
In the guide, go to
Contents
→
System Management
→
Environmental Monitoring and Power Management
.
Cisco Catalyst 9600 Series Switches Hardware Installation Guide
10
Product Overview
Power Supply Modes
Содержание Catalyst 9600 Series
Страница 104: ...Cisco Catalyst 9600 Series Switches Hardware Installation Guide 100 LEDs Line Card LEDs ...
Страница 110: ......