7-11
Installing Cisco Intrusion Prevention System Appliances and Modules 5.0
78-16124-01
Chapter 7 Installing IDSM-2
Installation and Removal Instructions
•
Log in to the switch CLI and enter one of the following commands:
–
For Catalyst software:
set module shutdown
module_number
–
For Cisco IOS software:
hw-module module
module_number
shutdown
•
Shut down IDSM-2 through IDM.
•
Press the Shutdown button.
Note
Shutdown may take several minutes.
Caution
If IDSM-2 is removed from the switch chassis without first being shut down, or the chassis loses power,
you may need to reset IDSM-2 more than once. If the module fails to respond after three reset attempts,
boot the maintenance partition, and perform the instructions for restoring the application partition.
Step 2
Verify that IDSM-2 shuts down. Do not remove IDSM-2 until the status indicator is amber or off.
Step 3
Use a screwdriver to loosen the installation screws at the left and right sides of IDSM-2.
Step 4
Grasp the left and right ejector levers and simultaneously pull the left lever to the left and the right lever
to the right to release IDSM-2 from the backplane connector.
Step 5
As you pull IDSM-2 out of the slot, place one hand under the carrier to support it.
Caution
Do not touch the printed circuit boards or connector pins.
Step 6
Carefully pull IDSM-2 straight out of the slot, keeping your other hand under the carrier to guide it.
Note
Keep IDSM-2 at a 90-degree orientation to the backplane (horizontal to the floor).
Step 7
Place IDSM-2 on an antistatic mat or antistatic foam.
Step 8
If the slot is to remain empty, install a filler plate (part number 800-00292-01) to keep dust out of the
chassis and to maintain proper airflow through the module compartment.
Warning
Blank faceplates and cover panels serve three important functions: they prevent exposure to
hazardous voltages and currents inside the chassis; they contain electromagnetic interference (EMI)
that might disrupt other equipment; and they direct the flow of cooling air through the chassis. Do not
operate the system unless all cards, faceplates, front covers, and rear covers are in place. Statement
1029
For More Information
•
For more information on ESD-controlled environments, see
Site and Safety Guidelines, page 1-17
.
•
For the procedure for resetting IDSM-2, see
Resetting IDSM-2, page 7-13
.